SMC Corporation of America
Elite Part Number Search
Search Results "LEKFS40EA-1100-R5C917"

Bar type Bar length Sensor Emitter cartridge type/Emitter material Bar length 300 mm 380 mm 620 mm 780 mm 1100 mm 1260 mm 1500 mm 1900 mm 2300 mm Symbol 300 380 620 780 1100 1260 1500 1900 2300 Without sensor Autobalance sensor [Body-mounting type] Nil E F G Symbol Nil C S J K Emitter cartridge type Emitter material With feedback sensor Autobalance sensor [High-precision type] Tungsten Silicon

1100 200 450 Rated flow (L/min (ANR)) Note 1) Polycarbonate Bowl material Bowl guard Standard (Polycarbonate) Semi-standard (Steel) Relieving type Regulator construction 0.82 1.26 1.42 0.38 0.67 Weight (kg) Note 1) Conditions: Mist separator inlet pressure: 0.7 MPa; The rated flow varies depending on the inlet pressure.

Applicable strokes: 250, 350, 450, 550, 650, 700, 750, 850, 900, 950, 1050, 1100, 1150, 1250, 1300, 1350, 1400, 1450 Example) LJ1H3031PD-250-F2-X2 Allowable Moment (Nm) Allowable static moment Allowable dynamic moment Pitching Rolling Yawing Mounting orientation Load movement direction 117 137 123 Model LJ1H30 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep a = 1000 2000 L1

) (1100) (1100) 40 40 (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1MW25 MY1CW25 l l MY1CW25 MY1CW25 30 30 (1000) (1000) (1000) MY1MW20 MY1MW20 MY1MW20 (1000) (900) (1000) (900) (1000) (900) MY1CW20 MY1CW20 MY1CW16 MY1MW16 MY1MW16 MY1MW16 MY1CW16 MY1CW16 (900) (900) (900) Caution 20 20 10 10 1.

1100 1100 1200 1400 2350 2650 2900 1750 130 65 80 310 166 + 0.5S 110 140 180 220 1750 1750 1750 1950 2400 3450 4300 4700 2750 200 110 130 560 240 + 0.5S Option Specifications Stroke Adjustment Range of Adjuster Options (Identical for extension and retraction ends) Type Stroke adjustment range Optional wide adjustment range adjusters are available with rubber stopper and metal stopper.

50 to 2000 50 to 2000 20 150 to 250 150 to 1300 100 to 2000 50 to 2000 50 to 125 50 to 1100 50 to 2000 50 to 2000 30 50 to 200 50 to 1300 50 to 2000 50 to 2000 50 to 125 50 to 1100 50 to 2000 50 to 2000 effect before installing. 3-1-5.

Applicable strokes: 250, 350, 450, 550, 650, 700, 750, 850, 900, 950, 1050, 1100, 1150, 1250, 1300, 1350, 1400, 1450 Example) LJ1H3031PD-250-F2-X2 Allowable Moment (Nm) Allowable static moment Allowable dynamic moment Pitching Rolling Yawing Mounting orientation Load movement direction 117 137 123 Model LJ1H30 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep a = 1000 2000 L1

Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 Pressure gauge port size [AR] 1 1/8 Fluid Air Ambient and fluid temperature 2 5 to 60C (with no freezing) Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Set pressure range [AR] 0.05 to 0.85 MPa Nominal filtration rating [AF/AFM] AF: 5 m, AFM: 0.3 m (99.9% filtered particle size) Rated flow [L/min(ANR)] [AFM] 3 200 450 450 1100

Refrigerant charge kg 0.32 0.33 0.34 Control method Compressor ON/OFF Ambient temperature/Humidity/Altitude Note 1), 11) Temperature: 5 to 40C, Humidity: 30 to 70%, Altitude: less than 3000 m HRW HECR HEC Circulating fluid Note 2) Tap water, 15% ethylene glycol aqueous solution Set temperature range Note 1) C 10 to 30 Cooling capacity (50/60 Hz) Note 3), 11) W 1000/1200 For option -T: 900/1100

Outlet air pressure dew point Model Rated inlet condition Air flow capacity (m3/h [ANR]) Port size IDFA100F-38 IDFA125F-38 IDFA150F-38 IDFA100F-40 IDFA125F-40 IDFA150F-40 960 1210 1500 860 1100 1340 R 2 R 2 1/2 DIN flange 80 R 2 R 2 1/2 DIN flange 80 40C 0.7 MPa 10C 35C 0.7 MPa 3C 89 A INDEX 1.

[AF/AFM] 0.1 MPa Set pressure range [AR] 0.05 to 0.85 MPa Max. flow capacity*3 [AFM] 200 L/min (ANR) 450 L/min (ANR) 1100 L/min (ANR) Nominal filtration rating*4 [AF] 5 m [AFM] 0.3 m (99.9% filtered particle size) Outlet side oil mist concentration*5, *6 [AFM] Max. 1.0 mg/m3 ( 0.8 ppm) Compressed air purity class*7 ISO 8573-1:2010 [ 3 : 4 : 3 ]*8 Drain capacity [AF/AFM] 8 cm3 25 cm3 45 cm3

Operating condition Model LC3F2 A LEC-MR-RB-032 B LEC-MR-RB-12 Allowable Stroke Speed [mm/s] Model AC servo motor Lead Stroke [mm] Symbol [mm] Up to 100 Up to 200 Up to 300 Up to 400 Up to 500 Up to 600 Up to 700 Up to 800 Up to 900 Up to 1000 Up to 1100 Up to 1200 H 20 1500 1200 900 700 550 A 12 900 720 540 420 330 B 6 450 360 270 210 160 LEFS25 100 W /l40 (Motor rotation speed) (4500 rpm

) (1100) (1100) 40 40 (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1MW25 MY1CW25 l l MY1CW25 MY1CW25 30 30 (1000) (1000) (1000) MY1MW20 MY1MW20 MY1MW20 (1000) (900) (1000) (900) (1000) (900) MY1CW20 MY1CW20 MY1CW16 MY1MW16 MY1MW16 MY1MW16 MY1CW16 MY1CW16 (900) (900) (900) Caution 20 20 10 10 1.

(Window comparator) 1250 0x04E2 1ot (Selection of output type) Setting of OUT1 output normal and reserved output U8 0 Y 0: 1_P (Normal output) 1: 1_n (Reverse output) 2 R/W P_1 (n_1) (Selection of output set value) Setting range 0xFFCE to 0x041A (-50 to 1050) Setting of OUT1 output set value (Hysteresis) S16 500 Y 1 R/W H_1 (Setting of OUT1 hysteresis) Setting range 0x0 to 0x044C (0 to 1100

Flow L/min 50 to 250 20 to 280 250 L Flow cfm 13 to 66 5 to 74 PD 200 to 1000 80 to 1120 Temperature oC 0 to 100 -10 to 110 50 oC Temperature oF 32 to 212 14 to 230 PD 0 to 1000 -100 to 1100 Flow L/min 0.0 to 10.0 0.0 to 10.5 10 L Flow gal/min 0.000 to 0.353 0.000 to 0.370 PD 0 to 1000 0 to 1050 Flow L/min 0.0 to 50.0 0.0 to 52.5 50 L Flow gal/min 0.00 to 1.76 0.00 to 1.86 PD 0 to 1000 0

refrigerated type type type type type type Refrigerant R407C(HFC) Quantity of refrigerant kg 0.35 0.3 0.36 0.31 0.36 0.31 Control method PID control Ambient temperature and humidity2 Temperature: 5 to 40oC18 Humidity: 30 to 70% Circulating fluid3 Tap water, Ethylene glycol aqueous solution 15%5 Operating temperature oC 5 to 40 range2 Circulating fluid system Cooling capacity4 (50/60Hz) W 1100

Air-Cooled refrigerated type Refrigerant R134a(HFC) R410A(HFC) Quantity of refrigerant kg 0.24 0.22 Control method PID control Ambient temperature andhumidity and altitude 1 Temperature:5 to 40,Humidity:30 to 70%,Altitude: Less than 3000m Circulating fluid2 Tap water, Ethylene glycol aqueous solution 15% Operating temperature range1 15 to 35 Cooling capacity (50/60Hz) 3 W 770 / 950 950 / 1100

R410A(HFC) Quantity of refrigerant kg 0.72 0.74 Control method PID control Ambient temperature andhumidity and altitude 12 Temperature:5 to 40,Humidity:30 to 70%,Altitude: Less than 3000m Circulating fluid*3 Tap water, 15% ethylene glycol aqueous solution Operating temperature range1 5 to 35 Cooling capacity (50/60Hz) 4 W 4600/ 5100 4800/ 5800 Heating capacity (50/60Hz) 5 W 1000/ 1200 1100

No bellows With bellows S 1 pc. 40 25 to 850 25 to 700 50 25 to 800 25 to 650 n n pcs. 63 25 to 800 25 to 650 80 25 to 750 25 to 600 100 25 to 750 25 to 600 Bore size (mm) Available stroke (RFS) No bellows With bellows 40 To 1200 To 950 50 To 1150 To 900 63 To 1150 To 900 80 To 1100 To 900 100 To 1100 To 850 Applicable autoswitch types Refer to the autoswitch catalog for details. 11 2-2-2