SMC Corporation of America
Elite Part Number Search
Search Results "LEKFS32LT7H-300-S592"

Accuracy: H (High Precision Type), Size: 32, Motor Mounting: Top Mounting Position, Motor Type: T7 [AC Servo Motor, (Absolute Encoder), Output 200W], Lead: A [LEY25, 12mm; LEY32, 16(20)mm], Stroke: 350mm, Motor Option: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: 5m, Driver: 92 (LECSN2-T-9, 200~240V, Absolute

Series: Clean Series Ball Screw Drive, Accuracy: Basic Type, Size: 40, Motor Type: 400W Output, Absolute Encoder, Lead: LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm, Stroke: 950mm, Motor Option: w/o Lock, Vacuum Port: Both Left and Right, Actuator Cable Type: Standard Cable, Actuator Cable Length: 5m, Driver Type: LECSN2-T-9, 200~240V, Absolute, EhterNet/IPâ„¢ Card, I/O Connector: -

Accuracy: High Precision Type, Size: 32, Motor Mounting: In-line Type, Motor Type: T7 [AC Servo Motor, (Absolute Encoder), Output 200W], Lead: A [LEY25, 12mm; LEY32, 16(20)mm], Stroke: 500mm, Motor Option: w/Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: Standard Cable, Cable Length: 5m, Driver: LECSN2-T-9, 200~240V, Absolute, EhterNet/IPâ„¢ Card

Accuracy: High Precision Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: T7 [AC Servo Motor, (Absolute Encoder), Output 200W], Lead: A [LEY25, 12mm; LEY32, 16(20)mm], Stroke: 350mm, Motor Option: w/Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: Standard Cable, Cable Length: 5m, Driver: LECSN2-T-9, 200~240V, Absolute, EhterNet/

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size.áDirectáor bracket mountings are available in three directionsáor types. áThrust, speed and positioning * can beámanaged with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.High output motor

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

Type M10/M11 manifold At 300 mm/s 4, 6, 8 fittings are connectable. 32 At 300 mm/s Existing 6, 8, 10, 12 fittings are connectable. Valve size Valve size 50 50 DOWN DOWN Existing At 300 mm/s Possible to drive cylinders Up to 50 Valve size Valve size 63 63 DOWN DOWN (80 at 100 mm/s) Existing Possible to drive cylinders Up to 63 80 Page 30 (125 at 100 mm/s) Sub-plate newly added!

rate: 50% Stroke 300 mm Series MB, CA2 Pressure 0.5 MPa Load rate: 50% Stroke 500 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation SY3140-01 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5140-02 800 700 600 500 400 300 200 100 0 SY7140-03 800 700 600 500 400 300 200 100 0 SY9140-04 Cylinder is in extending.

Note) Standard lead wire length: 300 mm.

Standard length is 300 mm, but the following lengths are also available.

T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.

200 100 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 MY3B max.

150 Nil C D Nil H L S 300 300 75 Auto-drains listed on page 95 are attached.

= 100 V = 100 3 3 V = 200 V = 200 2 2 V = 300 V = 300 V = 500 1 1 0 0 50 100 150 200 250 300 0 0 50 100 150 200 250 300 350 400 L3: Overhang Allowable range: 300 mm L3: Overhang Allowable range: 400 mm Allowable overhang L [mm] Allowable overhang L [mm] 167 Model Selection MXQ Series Determine the overhang.

400 500 600 700 800 900 1000 1200 1500 CABLEVEYOR LJ1S101SC 88 128 116 94 to 300 146 LJ1S202SC 90 130 118 96 to 300 LJ1H101SC 6 48 to 500 LJ1H101PB 2 122 110 44 to 600 104 145 LJ1H101NB 4 46 to 600 LJ1H202SC 124 16 112 58 to 500 LJ1S303SC 146 132 92 120 98 to 300 to 300 to 300 LJ1H202PA 8 50 to 500 124 112 106 LJ1H202NA 12 54 to 500 LJ1H303SE 126 114 22 64 to 500 to 500 to 500 LJ1H202PC

300 100 MI W S 100 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 300 CEP1 Max. 500 mm/s of high speed transfer is possible.