(900) (1000) (1000) MY1CW20 MY1CW20 MY1CW20 MY1CW16 MY1MW16 MY1MW16 MY1CW16 MY1CW16 (900) (900) (900) (900) (900) (900) 20 20 10 10 0 1000 2000 3000 4000 0 1000 2000 3000 (mm) (mm) 4000 Support spacing (l) Support spacing (l) 8-12-22 23 Series MY1W Mechanically Jointed Rodless Cylinder With Protective Cover Proper Auto Switch Mounting Position (Detection at stroke end) Note) The operating
) (1000) (900) (1000) (1000) Caution MY1CW20 MY1CW20 MY1CW16 MY1MW16 MY1MW16 MY1CW16 (900) (900) (900) (900) (900) (900) 20 20 1.
distance [mm] wStatic Neutralization Range IZF10 IZF10-L 300 mm 300 mm 8 s 8 s 4 s 4 s 0 0 2 s 6 s 2 s 6 s 300 mm 300 mm 600 300 900 1200 600 300 900 1200 Installation distance [mm] Installation distance [mm] IZF10R (Air flow level: 4) IZF10R (Air flow level: 1) 300 mm 300 mm 6 s 2 s 8 s 6 s 4 s 2 s 8 s 0 0 4 s 300 mm 300 mm 600 300 900 1200 600 300 900 1200 Installation distance [mm] Installation
(900) (1000) (1000) MY1CW20 MY1CW20 MY1CW20 MY1CW16 MY1MW16 MY1MW16 MY1CW16 MY1CW16 (900) (900) (900) (900) (900) (900) 20 20 10 10 0 1000 2000 3000 4000 0 1000 2000 3000 (mm) (mm) 4000 Support spacing (l) Support spacing (l) 8-12-22 Proper Auto Switch Mounting Position (Detection at stroke end) Note) The operating range is a guide including hysteresis, but is not guaranteed.
Removal of electrode cartridge Mounting of electrode cartridge Handling Caution 1) Do not drop, hit or apply excessive shock (100m/s2 or more) to the product. Even if the ionizer body is not damaged, the internal components may be damaged, leading to a malfunction. 2) When installing the product, handle the product so that no moment is applied to the controller and the ends of the bar.
/s2) 22 36 Work load [kg] *2 3000(mm/s2) 14 29 80 5000(mm/s2) 12 29 30 Vertical 9800(mm/s2) 8 9 Actuatr specifications Electric specifications Lock unit to 500 2300 1250 500 Max. speed *3 501 to 1000 1600 800 320 [mm/s] 1001 to 1500 900 450 180 Lead [mm] Lost motion [mm] *4 Positionimg repeatability [mm] Max. acceleration/deceleration [mm/s2] 9800 0.01 0.05 or less 50 25 10 Actuation type
After improvement Before improvement Conventional coil tube model Filter regulator Conventional coupler model S coupler 1 2 1 2 Coil tube L L VMG Air gun Nozzle 2.5 Nozzle 3 S2 S0 to S1 S2 S0 to S1 Effective area ratio 3.04 : 1 Effective area ratio 0.69 : 1 Before improvement After improvement Coupler S coupler Conventional model Piping Equipment TCU1065-1-20-X6 Conventional coil tube model
(I.D. 5, equivalent length 5 m) Air gun VMG (Nozzle size 2.5) Conventional model (Nozzle size 3) Coupler, Piping (S0) 13.45 mm2 5.1 mm2 Effective area Air gun (S1) 30 mm2 6 mm2 Nozzle (S2) 4.4 mm2 6.3 mm2 0.69 : 1 3.04 : 1 Effective area ratio (S0 to S1: S2) Impact pressure 0.011 MPa (at a distance of 100 mm) 0.011 MPa (at a distance of 100 mm) Regulator pressure 0.4 MPa 0.5 MPa Pressure
Setting example of pulse signal Actuator lead: 10[mm/rotation], electronic gear (denominator): 1, electronic gear (numerator): 1 2 pulse mode (Pulse input for each direction) Target position1: Travel amount 100mm Travel speed 30mm/s Acceleration 3000mm/s2 Deceleration 3000mm/s2 Target position2: Travel amount 60mm Travel speed 100mm/s Acceleration 2000mm/s2 Deceleration 2000mm/s2 Calculation
Mount the switch in a location where there is no vibration greater than 98 m/s2, or no impact greater than 490 m/s2. With a switch with orifice, the adjusted flow rate value could be affected by vibration. 3. Do not use in an area where surges are generated.
0.49 to 4.90 m/s2 0.98 to 9.80 m/s2 1.96 to 19.6 m/s2 Nominal size:16 5kg 1.25kg 10kg 2.5kg Maximum load weight NOTE2) Nominal size:25 20kg 5kg 10kg 2.5kg Acceleration and deceleration method Trapezoidal drive Moving direction Horizontal direction Positioning points Both ends (mechanical stoppers), 1 intermediate position Both ends 0.01mm Repeated Positioning stopping precision Intermediate
MY316 300 400 500 500 400 300 950 N Collision deceleration (m/s2) Collision deceleration (m/s2) 200 200 240 N 100 100 30 40 50 50 40 30 20 20 10 10 1 2 3 4 5 10 20 30 10 5 4 3 2 1 0.2 0.4 0.3 m1max m3max m1max m2max m3max m2max Weight (kg) Weight (kg) MY320 MY340 500 400 300 300 400 500 370 N Collision deceleration (m/s2) Collision deceleration (m/s2) 200 200 1500 N 100 100 50 40 30 30 40
0.49 to 4.90 m/s2 0.98 to 9.80 m/s2 1.96 to 19.6 m/s2 Nominal size:16 4(5)kg 1.25(1.25)kg 6(10)kg 2.5(2.5)kg Maximum load weight NOTE 1) Nominal size:25 11(20)kg 4(5)kg 8(10)kg 2.5(2.5)kg Acceleration and deceleration method Trapezoidal drive Moving direction Horizontal direction Positioning points Both ends (mechanical stoppers), 1 intermediate position 0.01mm Both ends Repeated Positioning
Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm 50 63 80 100 125 140 160 180 200 250 300 Average speed (mm/s) Series 1000 1100 Perpendicular, upward actuation 900 Horizontal actuation 800 700 600 500 400 300 200 100 VK VQ7-8-FG-S-A03 VQ7-8-FG-S-RA03 VZ VF 0 1000 1100 VFR 900 800 700 600 500 400 300 200
Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm 50 63 80 100 125 140 160 180 200 250 300 Average speed (mm/s) Series 1000 1100 Perpendicular, upward actuation 900 Horizontal actuation 800 700 600 500 400 300 200 100 VK VQ7-8-FG-S-A03 VQ7-8-FG-S-RA03 VZ VF 0 1000 1100 VFR 900 800 700 600 500 400 300 200
(Error number 5) 4 points preset input type Brown Blue S1 White Vs Black S2 Vs: Power supply 24 VDC (Negative common) One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2. S1 OFF ON OFF ON S2 OFF OFF ON ON Preset pressure P01 P02 P03 P04 For safety reasons, it is recommended that one of the preset pressures be set to 0 MPa.
(STO switch) S2: Start switch (STO release switch) S3: On switch S4: Off switch KM1: Magnetic contactor K3: Safety relay EMG: Emergency stop switch CN3 EM1 or EM2 M Servo motor Note.
Do not drop, bump or apply excessive impacts (300 m/s2 or more for reed auto switches and 1000 m/s2 or more for solid state auto switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause malfunction. 2. Observe the proper tightening torque for mounting an auto switch.
25 125 900 32 140 1100 40 170 1900 3.8-6 Platform Cylinder Series CXT Construction !