Acceleration Deceleration Can be set in units of 1mm/s2.
PB53] Gain characteristics 1 Hz 300 Hz Resonance of more than 300 Hz is not the target of control. Vibration suppression control 1 Vibration frequency Vibration suppression control 1 (anti-resonance frequency) Resonance frequency [Pr. PB19] [Pr.
speed mm/s Piston speed mm/s 5 Model Selection Series MY2 Moment/MY2HT (Double axis) MY2HT/M3 MY2HT/M1 MY2HT/M2 300 300 300 200 200 200 100 100 100 Moment Nm Moment Nm Moment Nm 50 50 50 MY2HT40 MY2HT40 MY2HT40 40 40 40 30 30 30 MY2HT25 20 20 20 MY2HT25 MY2HT25 MY2HT16 10 10 10 MY2HT16 MY2HT16 8 8 8 5 5 5 100 200 300 400500 1000 1500 100 200 300 400500 1000 1500 100 200 300 400 500 1000
T1 T2 T3 T4 L 0.5 V (T1 + T3) V T2 = L : Stroke [mm] (Operating condition) V : Speed [mm/s] (Operating condition) a1: Acceleration [mm/s2] (Operating condition) a2: Deceleration [mm/s2] (Operating condition) 500 0.5 300 (0.1 + 0.1) 300 T1 = V/a1 [s] T3 = V/a2 [s] = P T2: Constant speed time can be found from the following equation. = 1.57 [s] T4 = 0.3 [s] T2 = [s] L 0.5 V (T1
Refer to pages starting with 181 for mounting. 30 95 B 100 95 8(4)-6.2 (160) () () 110 95 20 95 A (140) () () A B Stroke Model LG1H202PA-100-F LG1H202PA-200-F LG1H202PA-300-F LG1H202PA-400-F 100 200 300 400 50 150 250 70 170 270 Dimenstions inside ( ) are for a 100 mm stroke. Positioning Time Guide Positioning time Positioning time (sec.)
PB53] Gain characteristics 1 Hz 300 Hz Resonance of more than 300 Hz is not the target of control. Vibration suppression control 1 Vibration frequency Vibration suppression control 1 (anti-resonance frequency) Resonance frequency [Pr. PB19] [Pr. PB20] Phase -90 deg.
400 500 Angular acceleration/deceleration: (/s2) Angular speed: (/s) LER30 LER30 0.030 1.4 LER30K High torque 1.2 0.025 LER30K High torque Moment of inertia: (kgm2) Effective torque: T (Nm) 1.0 0.020 0.8 LER30J Basic 0.015 LER30J Basic 0.6 0.010 0.4 0.005 0.2 0.000 0.0 100 1000 10 0 100 200 300 400 500 Angular acceleration/deceleration: (/s2) Angular speed: (/s) LER50 LER50 12 0.12
X505 [IP65 compatible] [IP65 compatible] [IP65 compatible] Manual override Nil: Non-locking push type D: Push-turn locking slotted type E: Push-turn locking lever type G: Lead wire length 300 mm H: Lead wire length 600 mm L: With lead wire (length 300 mm) M: With lead wire (length 300 mm) D: With connector Y: With connector T: Conduit terminal LN: Without lead wire MN: Without lead wire Light
for 2 hours in each direction (During de-energizing) Vibration resistance Impact resistance 300 m/s2 3 times for each X, Y, Z direction (During de-energizing) Standard CE marking Mass 160 g Dimensions 170 (39.6) 20 76 39 Fieldbus System Series EX600 Parts Description q t r w No.
) YO Terminal without Connector (VQZ200/300) YZ DIN Connector (VQZ200/300) YOS DIN Terminal without Connector (VQZ200/300) Note 1) Applicable to DC Specification Note 2) Optional Specification Note 3) When specifying more than one option, combine symbols in alphabetical order.
B2 Supply valve (N.O.) 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC Grommet L plug connector M plug connector G: Lead wire length 300 mm L: With lead wire (300 mm) M: With lead wire (300 mm) MN: Without lead wire U With light/surge voltage suppressor (Non-polar type) r Rated voltage DC CE-compliant 5 24 VDC V 6 12 VDC V V 6 VDC V S 5 VDC V R 3 VDC V * For type U, only DC voltage is available
Temperature abnormality On 16 Series E-MY2 Auto Switch Specifications Auto Switch Common Specifications Reed switch Solid state switch Type Leakage current 3-wire: 100 A or less 2-wire: 0.8 mA or less None Operating time 1.2 ms 1 ms or less 300 m/s2 1000 m/s2 Impact resistance 50 M or more at 500 VDC Mega (between lead wire and case) Insulation resistance Withstand voltage 1000 VAC for 1
Without release valve Without pressure sensor/switch for vacuum With pressure sensor 30 m/s2 Vibration resistance Note 1) Pilot operated dual 2 port Pilot operated 2 port Valve configuration 20 m/s2 0.3 to 0.6 MPa Operating pressure range With switch for vacuum Poppet seal Valve construction Without pressure sensor/switch for vacuum With pressure sensor 150 m/s2 Impact resistance Note 2)
Not required Lubrication Mounting orientation Free Impact/Vibration resistance (m/s2) Note) 300/50 Note) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve, each one time when pilot signal is ON and OFF .
100 200 300 400 500 600 V(mm/s) 0 100 200 300 400 500 600 V(mm/s) 0 0 100 200 300 400 500 600 V (mm/s) LEFS 16 LEFS 25 LEFS 32 50 12 20 W(kg) W(kg) 10 W(kg) W(kg) W(kg) W(kg) 6 40 6 15 8 30 8 6 8 10 5 5 20 4 5 12 10 16 10 12 16 10 2 0 0 0 0 100 200 300 400 500 600 V (mm/s) 0 100 200 300 400 500 600 V(mm/s) 0 100 200 300 400 500 600 V(mm/s) -9- (1)(DC24V) LEFS40 (mm) 1) 200,
(Manufacturable stroke range:LEJB40/ 200 to 2000mm, LEJB63/ 300 to 3000mm) Product Weight Series LEJB40 Stroke [mm] 200 300 400 500 600 700 800 900 1000 1200 1500 2000 Weight (kg) 5.7 6.4 7.1 7.7 8.4 9.1 9.8 10.5 11.2 12.6 14.7 18.1 Extra weight of lock (kg) S2:0.2 / S6:0.3 / T6:0.2 Series LEJB63 Stroke [mm] 300 400 500 600 700 800 900 1000 1200 1500 2000 3000 Weight (kg) 11.5 12.7 13.8 15.0
Kit/Electrical entry/Cable length F P Kit (Dsub connector) Kit (Flat cable connector) Connector location Top (vertical) Side (horizontal) Connector location Top (vertical) Side (horizontal) P .1.10-40 P .1.10-36 Without cable Without cable S0 S1 S2 S3 S0 S1 S2 S3 U0 U1 U2 U3 U0 U1 U2 U3 stations Max.16 (2) Max.16 (2) F kit P kit P kit F kit With cable (1.5m) With cable (3m) With cable (5m
PF2A703H--28 PF2A703H--68 PF2A706H--28 PF2A706H--68 PF2A703H--29 PF2A703H--69 PF2A706H--29 PF2A706H--69 3000 150 3000 150 6000 300 6000 300 PF2A712H--28 PF2A712H--68 PF2A712H--29 PF2A712H--69 12000 600 12000 600 13
HRGC-BP001(G) HRGC-BP005(G) 275 300 q This dustproof filter is secured with hook-and-loop tape.
When selecting the overhang, refer to "Calculation of Guide Load Factor" or the Electric Actuator Selection Software for confirmation, http://www.smcworld.com Dynamic Allowable Moment Acceleration/Deceleration 1000 mm/s2 3000 mm/s2 5000 mm/s2 Orientation Load overhanging direction m : Work load [kg] Me: Dynamic allowable moment [Nm] L : Overhang to the work load center of gravity [mm] Model