(Example) When STA = 20, STB = 5000 and STC = 200, the actual arc part times are as follows. At acceleration: 100 ms 20 20 = 100 [ms] < 200 [ms] Therefore, it will be limited to 100 [ms]. At deceleration: 200 ms 20 5000 = 400 [ms] > 200 [ms] Therefore, it will be 200 [ms] as you set. Setting range: 0 to 5000 5 90 5.
Controller USB cable Communication 120.3 120.3 mm mm 200 200 mm/s mm/s (type A to mini-B) cable 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN3 PC (PC is prepared by the user.) 20 - 4.4 CN4: Counter connector (option) Connect the controller to the Multi-counter (CEU5) using the counter cable (LATH3-). Refer to section 6.2 Counter plug wiring (P.24).
VAC (50 Hz) 200 to 220 VAC (60 Hz) 3-phase single HRG0057 kVA 6 HRG01014 kVA 440, 460 VAC (50 Hz) 440 to 500 VAC (60 Hz) HRG0157 18 kVA 3-phase double 220, 240, 380, 400, 415, 440 VAC (50/60 Hz) 8 200 VAC (50/60 Hz) Note) Refer to page 32 for dimensions.
JXC-OMY0008-A (2) Connection with a PC Controller 120.3 120.3 mm mm PC USB cable (A-miniB type) 200 200 mm/s mm/s Communication cable 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 SI PC is prepared by the user. When using the LEC-W2, it is necessary to connect a conversion unit (P5062-5) to the communication cable.
Impact acceleration [m/s2] 5 0 50 100 150 200 250 300 Speed [mm/s] Relationship between speed and impact acceleration 120 in vacuum environments (1.3 x 104 Pa) low leakage, and low outgassing.
Kit/Electrical entry/Cable length F P Kit (Dsub connector) Kit (Flat cable connector) Connector location Top (vertical) Side (horizontal) Connector location Top (vertical) Side (horizontal) P .1.10-40 P .1.10-36 Without cable Without cable S0 S1 S2 S3 S0 S1 S2 S3 U0 U1 U2 U3 U0 U1 U2 U3 stations Max.16 (2) Max.16 (2) F kit P kit P kit F kit With cable (1.5m) With cable (3m) With cable (5m
C2 LECSC2-T 200 to 230 2 2 S2 LECSS2-T 200 to 240 5 5 N2 LECSN2-T 200 to 240 A 10 E2 LECSN2-T-E 200 to 240 92 LECSN2-T-9 200 to 240 I/O cable length P2 LECSN2-T-P 200 to 240 Nil Without cable H Without cable Connector only 1 1.5 [m] Applicable Stroke Table Stroke Size 50 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 25 32 40 -9- AC servo motor LECY* series L E K F S
without control unit and bracket mounted, Others 30 m/s2, whichever is smaller for 2 hours in X, Y, Z direction each (De-energized) Vibration resistance Without control unit and bracket mounted: 980 m/s2, Others: 150 m/s2 in X, Y and Z direction, 3 times each (De-energized) Nil: Rc 1/8, N type: NPT 1/8, F type: G 1/8 4-core, oil resistant, cable (0.64 mm2) with M12, 4-pin pre-wired connector
Setting over 200 rev will be clamped with 200 rev. 0 0 to [rev] 1000 (Note) Note. Setting can be changed in [Pr. PC06].
.: P5062-5 To MOT 120.3 120.3 mm mm 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 Controller power supply To PWR 24VDC PC Power supply plug (Included) or USB cable
200 1003 5 10 20 30 1003 5 10 20 30 50 100 200 60 50 100 200 Horizontal Vertical (downward) Vertical (upward) m2 max. m1 max. m3 max. m1, m2, m3 max.
Operating conditions Model: LEFG40 Size: 40 Mounting orientation: Horizontal Acceleration [mm/s2]: 3000 Work load [kg]: 20 Work load center position [mm]: Xc = 0, Yc = 50, Zc = 200 2. Select the graphs for horizontal of the (11-)LEFG40 on page 60. LZ 3. Lx = 400 mm, Ly = 250 mm, Lz = 1500 mm 4.
Acceleration Deceleration Can be set in units of 1mm/s2.
After returning to the origin position, the SETON and INP signals are output. 0 Absolute: 200 Operation w [Specify Step No.2 to input the DRIVE signal.] 200 Absolute: 100 Step data No. defining operation The operation starts by specifying a registered step data No. to input the DRIVE signal.
300 400 500 Angular acceleration/deceleration: (/s2) Angular speed: (/s) LER30 LER30 0.030 1.4 LER30K High torque 1.2 0.025 LER30K High torque Moment of inertia: (kgm2) Effective torque: T (Nm) 1.0 0.020 0.8 LER30J Basic 0.015 LER30J Basic 0.6 0.010 0.4 0.005 0.2 0.000 0.0 100 1000 10 0 100 200 300 400 500 Angular acceleration/deceleration: (/s2) Angular speed: (/s) LER50 LER50 12
10 to 500Hz at whichever is smaller: 1.5mm amplitude or 98m/s2 acceleration in X, Y, Z directions for 2 hrs. each Vibration resistance 490m/s2 in X, Y, Z directions 3 times each Impact resistance Noise resistance 1000Vp-p, Pulse width 1s, Rise time 1ns Weight Note 3) 410g 470g 650g 1,100g Port size (Rc, NPT, G) 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 Note 1) The system accuracy when combined with PF2W3
Insulation resistance 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller. Vibration resistance 490 m/s2 in X, Y, Z directions 3 times each Impact resistance 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Noise resistance 200 g 240 g Weight Note 3) Port size (Rc, NPT, G) 1/8, 1/4 3/8 1/2 Note 1) The system accuracy when combined with PF2A2/3.
300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).