rubber N S U F GN GS 02 03 04 06 B08 2 3 4 6 8 Blast type: Work pieces can be removed easily.
(mm) Bracket assembly no. 1(P) 2(A) 4 90-VHK-B1A 4 4 6 90-VHK-B1A 6 1(P): One-touch fitting 2(A): One-touch fitting 1(P): Male thread 2(A): One-touch fitting 6 8 90-VHK-B1A 8 2(A) Applicable tubing O.D. (mm) 2(A) Applicable tubing O.D. (mm) 4 6 8 4 6 8 1(P) 1(P) 1(P): Male thread 2(A): One-touch fitting Applicable tubing O.D.
rubber N S U F GN GS 02 03 04 06 B08 2 3 4 6 8 Blast type: Work pieces can be removed easily.
3C 0D Answer ERR11 Reading offset No 05 36 33 36 0D 02 36 2D 31 35 32 03 3F 3B 0D Answer -1.52 deg.C 36 Offset setting (without writing FRAM) No 02 36 30 31 35 30 03 3F3C 0D 06 0D Set at +1.50 deg.C 37 Temperature setting (with writing FRAM) No 02 37 32 35 30 30 03 3F3E 0D 06 0D Set at 25.0 deg.C 38 Offset setting (with writing FRAM) No 02 38 30 31 35 30 03 3F3E 0D 06 0D Set at +1.50 deg.C
VQ7-6-FG-DVQ7-6-FG-D-R FHG FJG FIG FHG FJG FIG VQ7-6-DVQ7-6-D-R VQ7-6-FPG-DValve replacement parts FHG FJG FIG FHG FJG FIG Description Material VQ7-6-FG-SVQ7-6-FG-DVQ7-6-FPG-DVQ7-6-FG-S-R VQ7-6-FG-D-R VQ7-6-D-R VQ7-6-DNo.
6 Seal kit includes !4, !5, !6.
, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VQ7-6-FG-DVQ7-6-FG-D-R o o t r u t r u w y e q w y e q FHG FJG FIG FHG FJG FIG VQ7-6-DVQ7-6-D-R o o t r u t r u w y e q w y e q VQ7-6-FPG-Do t r u w y e q i Replacement Parts (For valve) FHG FJG FIG FHG FJG FIG Description VQ7-6-FG-SVQ7-6-FG-DVQ7-6-FPG-DVQ7-6-FG-S-R VQ7-6-FG-D-R VQ7-6-
M KPL04-01 KPL04-02 KPL06-01 KPL06-02 KPL08-01 KPL08-02 KPL10-02 KPL10-03 KPL12-03 KPL12-04 1/8 1/4 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 12 14 12 24.5 26.5 27 29 30 31.5 35.5 36.5 38.5 41.5 23.2 27.2 24.4 28.4 26.6 29.4 32.1 33.1 34.3 38.3 4 5 5 6 8 9 13 14 15 18 4 18 20.7 3.5 10.4 3.5 10 D1 6 19.5 22.8 9 12.8 9 L2 A D2 14 8 21.5 26.3 15 15.2 22 12 H Connection threads 10 24 29.4 25 18.5 35 17
51 VQZ1000 2 to 20 stations l l Rc(PT) 1/8 lll In-line SY C4(4) C6(6) C8(8) Rc(PT)1/8 2 stations: 193 Addition per/ station: 54 VV5QZ25 VQZ2 50 VQZ2 51 VQZ2000 lll l l Rc(PT) 1/4 2 to 20 stations SYJ In-line SX 2 stations: 398 Addition per/ station: 102 1(P)port Rc(PT)3/8 35(R)port Rc(PT)1/4 C6(6) C8(8) C10(10) Rc(PT)1/4 l l VV5QZ35 VQZ3 50 VQZ3 51 VQZ3000 2 to 20 stations VK In-line lll
KPGY12-03 KPGY12-04 KPQY04-M5 KPQY04-01 KPQY04-02 KPQY06-M5 KPQY06-01 KPQY06-02 KPQY08-01 KPQY08-02 KPQY10-02 KPQY10-03 KPQY12-03 KPQY12-04 M5 1/8 1/4 M5 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 8 32.5 36.5 40.5 35 40 44 44.5 48.5 53.5 55 58 60.5 8 10 14 8 10 14 12 14 15.3 22 26 15.8 23.2 27.2 24.4 28.4 29.9 31.9 33.1 37.1 6 13 19 7 14 20 14 22 29 39 41 68 4 18 4 4 20.7 10.4 D1 10 M M L1 8 L2 A 6
KPGY12-03 KPGY12-04 KPQY04-M5 KPQY04-01 KPQY04-02 KPQY06-M5 KPQY06-01 KPQY06-02 KPQY08-01 KPQY08-02 KPQY10-02 KPQY10-03 KPQY12-03 KPQY12-04 M5 1/8 1/4 M5 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 8 32.5 36.5 40.5 35 40 44 44.5 48.5 53.5 55 58 60.5 8 10 14 8 10 14 12 14 15.3 22 26 15.8 23.2 27.2 24.4 28.4 29.9 31.9 33.1 37.1 6 13 19 7 14 20 14 22 29 39 41 68 4 18 4 4 20.7 10.4 D1 10 M M L1 8 L2 A 6
P = 11.5 1 2 3 4 5 6 7 8 ... n: Stations 40.5 Silencer cover L Blanking plug (for One-touch fitting) Dimensions Applicable fitting size d 3.2 4 6 8 A 23 04 06 08 Model A L D KQ2PKQ2P-23 KQ2P-04 KQ2P-06 KQ2P-08 16 16 18 20.5 31.5 32 35 39 3.2 6 8 10 This is inserted into cylinder ports and SUP and EXH ports that are not used.
With float type auto-drain With drain guide Port size A B C D E J K L M N F G H Model P IDG3M/3HM/5M/5HM IDG10M/10HM 157 201 226 150 146 56 87 196 162 158 99 1/8, 1/4 5.5 66.5 35 210 196 15 9 IDG20M/20HM 1/4, 3/8 205 201 66 130 209 13 12 223 209 IDG30M/30HM 162 158 87 6 78 40 20 303 IDG30LM 149 145 56 86 196 9 210 196 5.5 7 5.5 70 95 70 35 50 35 15 22 15 IDG50M/50HM 3/8 177 172 80 87 241
Metric sizes Inch sizes Body Class Type LQ-GP J PAX 3 03 03 10 10 10 12 12 12 19 19 19 25 25 1/8" 03 03 03 03 3/16" 05 05 1/4" 07 07 07 3/8" 11 11 1/2" 13 13 3/4" 19 19 1" 25 4 04 04 04 04 6 06 06 06 8 08 Insert pin holder assembly (with the parts case) Type Insert pin/ Holder type 1 2 1 2 3 4 5 6 J PB Insert pin material (J/K type only) Nil N Metric sizes Inch sizes Nil S Resin
Width across flat Effective area (mm2) Connection thread Rc Weight (g) L1 L2 M d Model H1 H2 H2 H1 I.D. 2.5 3 4 6 7.5 8 9 10 13 4 4 6 8 10 10 12 12 16 KFG2F0425-02 KFG2F0403-02 KFG2F0604-02 KFG2F0806-03 KFG2F1075-03 KFG2F1008-03 KFG2F1209-03 KFG2F1210-03 KFG2F1613-04 1.6 2.6 6 17 30 35 45 57 101 1/4 1/4 1/4 3/8 3/8 3/8 3/8 3/8 1/2 1.8 2.3 3.3 5.3 6.8 7.3 8 9 12 d 17 8 25.9 16.4 5 24 17 19
I.D. 6 4 5 6 6.5 7.5 8 9 KFE06-02 KFE08U-03 KFE08N-03 KFE10U-03 KFE10N-03 KFE12U-03 KFE12N-03 1 4 41 49 50 63 62 93 91 37.5 17 17 44.2 16 15.2 3 4 5 5.5 6.5 7 8 M10 1 11 6 11 17 21 30 35 45 12 13 8 3 8 M12 1 46.2 39.5 17 16.2 19 19 14 3 8 10 M15 1 16 48.8 41.5 17 18.8 19 22 17 12 3 8 18 51.3 44.5 17 19.3 22 24 19 M17 1 Bulkhead union: KFE Applicable tube (mm) Effective orifice (mm 2) Mounting
Bore size (mm) T1 M F E D B T2 Part no. 42 50 62 76 6 8 10 12 16 20 25 30 6.8 9 11 14 18 20 26 31 6.5 6.5 8.5 10.5 10 12 16 18 YA-03 YA-05 YA-08 YA-10 32, 40 50, 63 80 100 YA 03 Applicable cylinder bore size 32, 40 50, 63 80 100 03 05 08 10 Mounting bracket Bore size (mm) W V U Weight (g) Part no.
Connector wiring diagram (mixed wiring) Connector type manifold 6 A 4 A 3 A 1 A 5 B 2 B Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing
CLS YA YB YU Type A mounting bracket Type B mounting bracket Joint 32, 40 50, 63 80 100 YA-03 YA-05 YA-08 YA-10 56 67 83 100 18 22 28 36 6 8 10 12 55 100 195 340 CLQ MLGP Applicable mounting bracket Bore size (mm) Joint RLQ Type A mounting bracket Type B mounting bracket Type B Mounting Bracket 32, 40 YU-03 YA-03 YB-03 MLU 50, 63 YU-05 YA-05 YB-05 80 YU-08 YA-08 YB-08 ML1C 100 YU-10 YA-10
6 4-R3 6 6 PAX 4-R3 4-R3 (Max. 91) 325 PB (Max. 91) 191 87 60 87 60 112 112 17-5-37 35 Series LV Fitting Assembly Procedure Assemble fittings following the procedure shown below.