SMC Corporation of America
Elite Part Number Search
Search Results "JMDBF63TN-400-W"

No anchor bolt is included. 76 A Thermo-chiller Water-cooled 200 V/400 V Type Standard Type (Only 400 VAC type) RoHS HRS090 Series HRS How to Order HRS 090 HRS 090 W 090 HRS 20 HRS 100/150 Cooling capacity Option HRSH 090 090 9 kW Nil None B Note) With earth leakage breaker J With automatic fluid fill function M Applicable to deionized water piping Cooling method W Water-cooled refrigeration

500 600 V(mm/s) 0 100 200 300 400 500 600 V(mm/s) 0 0 100 200 300 400 500 600 V (mm/s) LEFS 16 LEFS 25 LEFS 32 50 12 20 W(kg) W(kg) 10 W(kg) W(kg) W(kg) W(kg) 6 40 6 15 8 30 8 6 8 10 5 5 20 4 5 12 10 16 10 12 16 10 2 0 0 0 0 100 200 300 400 500 600 V (mm/s) 0 100 200 300 400 500 600 V(mm/s) 0 100 200 300 400 500 600 V(mm/s) -9- (1)(DC24V) LEFS40 (mm) 1) 200, 300, (400), 500

350, 400, 450, 500, 600, 700, 800, 900, 1000 63 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100 80 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200 100 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300 Intermediate strokes and short strokes other than the above are produced upon receipt of order.

Load Mass Allowable Moment E-MY2H/M1 E-MY2H/M3 E-MY2H/M2 E-MY2H/m3 60 60 50 60 60 50 50 50 40 40 30 30 30 30 q r w et 20 20 20 20 Load Mass (kg) Moment (NNm) Moment (NNm) Moment (NNm) 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 MY2H16 4 4 4 4 3 3 3 3 MY2H16 MY2H16 2 2 2 2 MY2H16 0.2 1 1 1 100 200 300 400 500 1000 1500 1 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200

32 20 22 15 33 43 1.0 Foot: M Rod flange: G Head flange: G (40)1 (40)1 (40)1 (40)1 (100)1 (100)1 0.3 G G (40)1 (40)1 (40)1 (40)1 (100)1 (100)1 0.5 W W Rod (side) W (40)1 (40)1 (40)1 (40)1 (100)1 (100)1 0.7 (40)1 (40)1 (40)1 (100)1 0.3 38 79 0.1 (40)1 (40)1 Head ( side ) 0.5 37 29 60 76 600 500 400 300 1000 1100 900 800 700 200 100 0 Cylinder stroke [mm] (40)1 0.7 34 30 23 50 63 1 The data

Pressure gauge unit 2) w q w q w q Unit psig/bar MPa Code No code MPA Sample Order Number Port AP1001S e q FV4 FV4 FV4 FV4 w FV4 FV4 FV4 FV4 r 2PW 3PW 2PW 3PW 3PW 4PW 2) Pressure gauge unit MPa or psig/bar selectable.

Contact SMC in this case. 1 Guide Cylinder Series MGG Models and Specifications JIS symbol Models and strokes Long stroke (mm) Standard stroke (mm) Model Bearing type Bore size (mm) 20 250, 300, 350, 400 75, 100, 125, 150, 200 25 350, 400, 450, 500 MGGM Slide bearing 32 350, 400, 450, 500, 600 40 350, 400, 450, 500, 600, 700, 800 75, 100, 125, 150, 50 350, 400, 450, 500, 600, 700, 800, 900

Application examples Horizontal transfer of workpieces, transfer of tools, low thrust clamping 32 mm Purpose of usage q 8 23 mm 1 kg Purpose of usage w Purpose of usage w 40 mm Purpose of usage w 27 mm 12 A guide with higher rigidity is necessary without 2 kg changing the thrust from the current model.

400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 Technical Data Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s) 1349 Mechanically Jointed Rodless Cylinder with Protective Cover Slide Bearing Guide Type, Cam Follower Guide Type MY1W Series 16, 20, 25, 32, 40, 50, 63 How to Order MY1 M W K 300 M9BW 32 Guide type M C Slide bearing

Applicable air dryer Capacity Type Inlet voltage Outlet voltage A B C D E F G Weight IDF-TR7000-8 IDF100F 7 kVA Three360 540 400 260 300 11 30 94 kg IDF-TR9000-8 IDF125F, 150F 9 kVA 400 650 450 300 350 13 40 109 kg IDF-TR14000-8 IDF190D, 240D 14 kVA 400 650 450 300 350 13 40 152 kg IDF-TR18000-8 IDF370D 18 kVA 400 650 450 300 350 13 40 179 kg 220, 240, 380, 400, 415, 440 V (50/60 Hz) phase

Example: Set 20 W (100 W 20%) for the 100-W external regenerative resistors with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur. 2. When set to the factory setting (Pn600 = 0), the DRIVERs built-in option has been used.

MB 32 10% 30% 50% 300 70% Stroke mm AS2201F -01-08 AS2200-01 200 100 70% 50% 30% 10% 0 400 MB 40 300 Stroke mm AS2201F -02-08 AS2200-02 200 100 0 ANA1 -C10 T0806 400 MB 50 300 Stroke mm AS3201F -02-08 AS3000-02 200 100 0 400 MB 63 300 Stroke mm AS4000-03 200 100 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end mm/s Applicable

Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur. 2. When set to the factory setting (Pn600 = 0), the DRIVERs built-in option has been used.

Graph (1) 400 st 500 st 600 st 700 st 400 st 500 st 600 st 700 st 10 5 4 300 st 300 st 3 200 st 200 st Load movement time: t (S) 2 [Example] 100 st 100 st 1 Example) 0.5 0.4 0.3 0.2 V' 0.1 V W 100 200 300 400 500 1000 Maximum speed: V (mm/s) Cylinder stroke Movement distance of load Step (2) Find the bore size.

Graph (1) 400 st 500 st 600 st 700 st 400 st 500 st 600 st 700 st 10 5 4 300 st 300 st 3 200 st 200 st Load movement time: t (S) 2 [Example] 100 st 100 st Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 Example) 0.5 0.4 0.3 0.2 V' 0.1 V W 100 200 300 400 500 1000

MBB50-PS-W MBB50-PS Cushion ring nut Chromium molybdenum steel Quench hard chrome plated @0 MBB63-PS-W MBB63-PS Hexagon socket head cap screw Chromium molybdenum steel Black zinc chromated @1 MBB80-PS-W MBB80-PS Rubber cap Chloroprene rubber @2 MBB100-PS-W MBB100-PS Cap A Black coated Aluminum casted 23A 23B The seal kits consist of items #0, #1, #2, #4 and #6.

2 w i A CJ1 CJP CJ2 A Cylinder tube sectional view A-A !0 o CM2 CG1 Component Parts MB No. q w e r t y u i o !0 !1 No.