Series: JSY3000, Type: Side-Ported, Serial Interface, EX260, SI Unit: DeviceNetâ„¢ - 32 Outputs - Connector M12, SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 3 Stations, P,E Port Location: D Side, 2 to 10 Stations, SUP/EXH Block: Internal Pilot, A,B Port Size: ø6 One-touch Fitting, Mounting: DIN Rail Mounting, DIN Rail Option: DIN Rail Mounting, w/DIN Rail, Combination Manifold
SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone
SS5Y7 8 STA MANIFOLD BASE, SY, 4/5 PORT SOLENOID VALVE, 0.00000 lb
Model: 10S (Side Ported), SI Unit Specification: QA (DeviceNetâ„¢ - 32 Outputs - Connector M12), SI Unit Ouput Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 8 Stations, P,E Port Entry: B (Both Sides, 2 to 16 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: N11 (ø3/8" One-touch Fitting, Straight, Inch)
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: Q (DeviceNetâ„¢), Input Block Stations: None, Input Block Type, Common Spec: A (Positive Common, M12, 2 Inputs), Valve Stations: 8 Stations, P,E Port Location, SUP/EXH Assembly: B (Port Location Both Sides, Internal Pilot), A, B Port Size: N7 (ø1/4" One-touch Fitting)
Model: 10S (Side Ported), SI Unit Specification: Q (DeviceNetâ„¢), Input Block Stations: None, Input Block Type, Common Spec: A (Positive Common, M12, 2 Inputs), Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: B (Port Location Both Sides, Internal Pilot), A, B Port Size: C8 (ø8 One-touch Fitting)
Model: 10S (Side Ported), SI Unit Specification: Q (DeviceNetâ„¢), Input Block Stations: None, Input Block Type, Common Spec: A (Positive Common, M12, 2 Inputs), Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: B (Port Location Both Sides, Internal Pilot), A, B Port Size: N7 (ø1/4" One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate)
Type: 10S (Side Ported), SI Unit Specification: QA (DeviceNetâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 8 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: N7 (ø1/4" One-touch Fitting)
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: QA (DeviceNetâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 08 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: C4 (ø4 One-touch Fitting)
Model: Side-Ported, Serial Interface, SI Unit Specification: DeviceNetâ„¢ - 32 Outputs - Connector M12, SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 08 Stations, P, E Port Location: Both Sides, SUP/EXH Block: Internal Pilot, A, B Port Size: ø1/4" One-touch Fitting, Mounting: -, DIN Rail Option: -
Model: Side-Ported, Serial Interface, SI Unit Specification: DeviceNetâ„¢ - 32 Outputs - Connector M12, SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 08 Stations, P, E Port Location: Both Sides, SUP/EXH Block: Internal Pilot, A, B Port Size: ø4 One-touch Fitting, Mounting: -, DIN Rail Option: -
Type: Side Ported, SI Unit Specification: DeviceNetâ„¢ - 32 Outputs - Connector M12, SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 8 Stations, P, E Port Location: Both Sides, SUP/EXH Block: Internal Pilot, A, B Port Size: ø8 One-touch Fitting, Mounting: -, DIN Rail Option: -
Type: Side Ported, SI Unit Specification: DeviceNetâ„¢ - 32 Outputs - Connector M12, SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 8 Stations, P, E Port Location: Both Sides, SUP/EXH Block: Internal Pilot, A, B Port Size: ø1/4" One-touch Fitting, Mounting: -, DIN Rail Option: -
Type: Side Ported, SI Unit Specification: DeviceNetâ„¢ - 32 Outputs - Connector M12, SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 8 Stations, P, E Port Location: Both Sides, SUP/EXH Block: Internal Pilot, A, B Port Size: ø1/4" One-touch Fitting, Mounting: DIN Rail Mounting w/o Name Plate, DIN Rail Option: -
Model: Side Ported, SI Unit Specification: DeviceNetâ„¢ - 32 Outputs - Connector M12, SI Unit Ouput Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 8 Stations, P,E Port Entry: Both Sides, 2 to 16 Stations, SUP/EXH Block: Internal Pilot, A,B Port Size: ø3/8" One-touch Fitting, Straight, Inch, Mounting: -, DIN Rail Option: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, NEW SY3000 MFLD, 2J, NEW SY3000 MFLD,NO SIZE RATING, 1.43300 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, NEW SY5000 MFLD, 2J, NEW SY5000 MFLD,NO SIZE RATING, 2.19492 lb
Type: 10S (Side Ported), SI Unit Specification: QA (DeviceNetâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 8 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A, B Port Size: C6 (ø6 One-touch Fitting)
Type: 10S (Side Ported), SI Unit Specification: QA (DeviceNetâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 16 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A, B Port Size: C6 (ø6 One-touch Fitting)
Type: 10S (Side Ported), SI Unit Specification: QA (DeviceNetâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 2 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A, B Port Size: C6 (ø6 One-touch Fitting)