Rc C4SF-6J-A G Rc C4SF-6-A G NPT C4SFN-6J(Z)-A NPT C4SF-6(Z)-A Option symbol Semi-standard symbol W 6W Semi-standard: "W" Standard Port thread type Part No. Rc C4SF-W-D G NPT C4SF-W(Z)-D Appearance and part No. Semi-standard: "6W" Standard Port thread type Part No.
Rc C3SF-6J-A G C3SFF-6J-A Rc G C3SF-6-A NPT C3SFN-6J(Z)-A NPT C3SF-6(Z)-A Option symbol Semi-standard symbol W 6W Semi-standard: W Piping port thread ty pe (9) Part No. Rc G NPT C3SF-W(Z)-D C3SF-W-D Appearance and part No. Semi-standard: 6W Piping port thread ty pe (9) Part No.
Rc C3SF-6J-A G C3SFF-6J-A Rc G C3SF-6-A NPT C3SFN-6J(Z)-A NPT C3SF-6(Z)-A Option symbol Semi-standard symbol W 6W Semi-standard: W Piping port thread ty pe (9) Part No. Rc G NPT C3SF-W(Z)-D C3SF-W-D Appearance and part No. Semi-standard: 6W Piping port thread ty pe (9) Part No.
Apparent power Apparent power (VA) 100V200V Voltage(V) Power con-sumption(W) 12 Inrush 50Hz 100 AC 24 32 48 60Hz 90 DC Holding 50Hz 20 13.2 60Hz 14 100 110 Use the actuator with allowable kinetic energy or less. Refer to 2-6. Allowable kinetic energy (Page 11) W a r n i n g Confirm the specifications. These product are designed only for use in compressed air systems (including vacuum).
C Note1) Option symbol Semi-standard W symbol Semi-standard: "W" Semi-standard: "C" Port thread type Part No. Port thread type Part No. Rc G NPT Rc G NPT AM54P-N120AS-C AM54P-120AS-C AM54P-120AS-W Appearance and Part No. D Note2) Option symbol Semi-standard symbol Semi-standard: "D" Part No. Port thread type Rc G NPT AM54P-N120AS-D AM54P-120AS-D Appearance and Part No.
C Note1) Option symbol Semi-standard W symbol Semi-standard: "W" Semi-standard: "C" Port thread type Port thread type Part No. Part No. Rc G NPT Rc G NPT AM54P-N120AS-C AM54P-120AS-C AM54P-120AS-W Appearance and Part No. D Note2) Option symbol Semi-standard symbol Semi-standard: "D" Part No. Port thread type Rc G NPT AM54P-N120AS-D AM54P-120AS-D Appearance and Part No.
C Note1) Option symbol Semi-standard W symbol Semi-standard: "W" Semi-standard: "C" Port thread type Part No. Port thread type Part No. Rc G NPT Rc G NPT AM54P-N120AS-C AM54P-120AS-C AM54P-120AS-W Appearance and Part No. D Note2) Option symbol Semi-standard symbol Semi-standard: "D" Part No. Port thread type Rc G NPT AM54P-N120AS-D AM54P-120AS-D Appearance and Part No.
-1-3 PRESET " " PRG STEP P1 P1 UPDOWN " " " 1 READ P1 " UP DOWN P8 P5 P6 P7 P1 P2 P3 P4 39 9-2 9-2-1 PROGRAM " " PRG 1 STEP 0 STEP 0 End " End PRG 1 UPDOWN No.
(P5 Precautions) Compared with the setting pressure, substances from the air source. cylinder thrust is unstable. 2) Selection of the Use metal seal type actuation valve. In case of rubber seal type, actuation valve the sliding resistance may increase due to grease splash on the main valve. (P5 Precaution) 3) Lateral load Use within the allowable lateral load range.
light: 0.5 W) Nil Y Solenoid valve rated voltage Only 24 VDC and 12 VDC are applicable to 0.45 W.
June 2015 P5 Installation CAUTION Air combination is added.
Press the push button to exhaust the condensate of the C3SF(-W)-A and C4SF(-W)-A. Check the element periodically and replace it with a new one if necessary. If it is found that outlet pressure drops or the flow is restricted, check the condition of the element. The manual exhaust for emergency case can be performed by counterclockwise rotation of the handle in AD17-A and AD27-A.
Nozzle Diameter: ø1.3, Body Style: 1S (Single Unit w/Valve + High Noise Reduction Silencer), Vacuum Port Location: A (Side Entry), Standard Supply Pressure: H (0.5 MPa), Thread Type: Rc, Supply/Release Valve: P5 (Air valve, Supply Valve), Solenoid Valve Rated Voltage: W/out Valve/Air Operated, Electrical Entry: W/out Valve/Air Operated, Light/Surge Voltage Suppressor: None, Manual Override
VH200 24404 (24404-1) 24408 24077 JIS B2401 P5 JIS B2401 P42 2407102A Series VH200 VH300 VH400 Part No. 244010 24418 240258 Material No.
Type: 3 [Standard, 100 â„“/min (ANR)], Port Size: 1 (One-touch Fitting: Size 3=ø10, Size 4=ø12), Digital Flow Switch: P5 [NPN Open Collector,1 Output+Analog Output (4 to 20mA)], Regulator: R1 (w/Regulator+Pressure Outlet Port Assembly), ON/OFF Valve: V2 [Manual Operation Valve (w/Lever Lock)], Restrictor: S (With Restrictor), Filter: F1 (With Filter w/Differential Pressure Indicator)
Type: 3 [Standard, 100 â„“/min (ANR)], Port Size: 2 (Rc1/4), Digital Flow Switch: P5 [NPN Open Collector,1 Output+Analog Output (4 to 20mA)], Regulator: R1 (w/Regulator+Pressure Outlet Port Assembly), ON/OFF Valve: V2 [Manual Operation Valve (w/Lever Lock)], Restrictor: S (With Restrictor), Filter: F1 (With Filter w/Differential Pressure Indicator)
ZL3 M 0 1 K1 5 LO Z 1 E A M G 1 ZL3 M 0 1 K1 5 LO Z 1 E A M G 1 ZL3 M 0 1 K1 5 LO Z 1 V A M W 1 1 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 4) 2) 1) 3 300L/min(ANR) M 0.35MPa *2 P 6 600L/min(ANR) H 0.50MPa 3)P V/ *23 (V) (P) 5/ 06 Rc3/4 K1 N.C.+N.C. 8() 04 2xRc1/2 K2 N.C. *1 F06 G3/4 B1 N.0.+N.C. *1 F04 2xG1/2 B2 N.O.
Type: 3 [Standard, 100 â„“/min (ANR)], Port Size: One-touch Fitting: Size 3=ø10, Size 4=ø12, Digital Flow Switch: P5 [NPN Open Collector,1 Output+Analog Output (4 to 20mA)], Regulator: w/Regulator+Pressure Outlet Port Assembly, ON/OFF Valve: V2 [Manual Operation Valve (w/Lever Lock)], Restrictor: With Restrictor, Filter: With Filter w/Differential Pressure Indicator