SMC Corporation of America
Elite Part Number Search
Search Results "ITV2030-SPN-N3-DUX02357"

This is a legacy product, and replaced byITV3050-SEN-N4-DUX02357, Operation Manual, N, ITV, "REGULATOR, N lb

This is a legacy product, and replaced byITV3030-SEN-N4-DUX02357, Operation Manual, N, ITV, "REGULATOR, N lb

Body Size: 20 (1500 L/min), Pressure Range: 10 (0.005~0.1Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 2 (1/4", 1000, 2000), Made to Order: X26 (Manifold Mounting)

Body Size: 20 (1500 L/min), Pressure Range: 50 (0.005 ~0.9Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 2 (1/4", 1000, 2000), Made to Order: X26 (Manifold Mounting)

Body Size & Pressure Range: Body Size: 1500 L/min; Pressure Range: 0.005~0.1Mpa, Protocol: PROFINET, Thread: Rc, Port: 2 [1/4, (1000, 2000)], Made to Order: Manifold Mounting

Body Size & Pressure Range: Body Size: 1500 L/min; Pressure Range: 0.005~0.9Mpa, Protocol: PROFINET, Thread: Rc, Port: 2 [1/4, (1000, 2000)], Made to Order: Manifold Mounting

No.IP8S-OM09 38 The following can be performed: angle check for a feedback lever (AnGL), balance current adjustment (0AdJ), automatic calibration (CAL), input current adjustment (S-0) & (S-F), confirmation of balance current (bAL), span adjustment (SPn), and initialize of parameter (dFLt). (C10) Angle check Confirm rotation angle of the feedback lever.

Procedure LCD display 1 Hold down Down or Up button ( ) at calibration mode to select span (SPn). Hold down the set button ( ) for 1sec. or longer. or 2 Go (Go) is displayed for confirmation. It is necessary to ensure no danger because the actuator operates. Then, hold down the set button ( ) for 1sec. or longer. 3 Zero-span adjustment starts.

To set pressure at 0.3MPa by ITV2030(for 0.5MPa type) (0.3MPa/0.5MPa)40952457DEC999(HEX) Pressure of 0.3MPa is set by sending input data of 999 to the electro-pneumatic regulator through the master PLC. 9 - Communication data allocation Set target value (from PLC to ITV) Resolution : 12bit (100%F.S.), Occupied byte : 2 Byte Target value (O area) Target value (Lower 12 bits) 12bit 0 0 0 0

To set pressure at 0.3MPa by ITV2030(for 0.5MPa type) (0.3MPa/0.5MPa)40952457DEC999(HEX) Pressure of 0.3MPa is set by sending input data of 999 to the electro-pneumatic regulator through the master PLC.

To set pressure at 0.3MPa by ITV2030( for 0.5MPa type) (0.3MPa / 0.5MPa)1023614 A pressure of 0.3MPa is set by sending input data of SET 614 to the electro-pneumatic regulator through the master PLC. Set pressure F. S. Set dat a Pressure 100% 75% 50% 25% 0% 0 256 512 767 1023 Input data 7 - Communication protocol The character-code used to communicate is ASCII.

To set pressure at 0.3MPa by ITV2030(for 0.5MPa type) (0.3MPa/0.5MPa)40952457DEC999(HEX) Pressure of 0.3MPa is set by sending input data of 999 to the electro-pneumatic regulator through the master PLC. 9 - Communication data allocation Bellow shows in the case of node address "1".

4 0 N 2 B S X80 2 0 3 0 ITV 33 DeviceNet compatible Model 2000 type 3000 type 2 3 Thread type Pressure range Rc(PT) NPT NPTF G(PF) Nil N T F Cable connector type 0.005 to 0.1MPa 0.005 to 0.5MPa 0.005 to 0.9MPa 1 3 5 Without Straight type 3m Nil S Option (bracket) Port size Without bracket Flat bracket L-bracket Nil B C 1/4 3/8 2 3 Specifications ITV2050 ITV3050 ITV2030 ITV3030 ITV2010 ITV3010

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com E SMC REGULATOR 2 OUT P G Connection thread type MPa IR N F PT NPT PF SUP 2 VEX G Manifold base (3 stations) 1 2 3 AMR IITV20-02-3 ITV2030-311S-X26 P398020-13 ITV2050-212S-X26 1 set (3 station manifold base part no.) 1 set (Electro-pneumatic regulator

BODY ASSEMBLY (KT-ITV2030-3R), INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, 21, IT2000 NO SIZEPART, 0.3784 lb

Part Number Description: CABLE(ITV2030-31N3L3-DIH00494)   Product Line: I   Product Line Description: INSTRUMENTATION   Family Code: 823   Family Description: IT2000/ITV2000 E/P REGULATOR   Class Code: 1X   Part Code: 1   Reference Code:  J   Click here to report information errorImage shown may not match exact part number

Bit BYTE 64 (Maximum) Value The Bits 49 54 56 32 30 33 30 2D 49 4C 32 42 4E (hexadecimal number) indicate "ITV2030-IL2BN." (ASCII code) 20 - Setting using buttons ! Caution If the incorrect key is pressed or incorrect information is displayed during setting, power must be shut off and the procedure started again.

Product ID ITV1010-IO-X395 *1 ITV1030-IO-X395 *1 ITV1050-IO-X395 *1 ITV2010-IO-X395 *1 ITV2030-IO-X395 *1 ITV2050-IO-X395 *1 ITV2090-IO-X395 *1 ITV3010-IO-X395 *1 ITV3030-IO-X395 *1 ITV3050-IO-X395 *1 ITV3050-IOF3N-DIT00375 *1: This becomes product ID added since FW Ver1.2.

Setting method Ex) In case that setting pressure is 0.3MPa on ITV2030(0.5MPa specification). (0.3MPa/0.5MPa) 1023 = 614 (Decimal) Binary data of 614( Decimal) is 10 0110 0110.

1A-X2 126 (Includes controller & connectors) (Includes controller & connectors) 110 100 29.5 Operating Pressure to 0.5MPa, Operating Temperature to 60C Media 2000 (41) 51 43 ( 100C coming soon ) 128.5 226.5 93 81.5 54 30 15 81.5 54 30 15 4 x M4 x 4 Mounting Holes For closed-loop liquid flow control above 3000 ml/min, SMC recommends the following combination. 4 x M4 x 4 Mounting Holes 20 ITV2030