Thread: NPT, Port: 3 [3/8" (2000, 3000)], Stations: 8 Stations, Pressure: 0.1 MPa, Protocol: Ethernet I/Pâ„¢
Thread: NPT, Port: 3 [3/8" (2000, 3000)], Stations: 8 Stations, Pressure: 0.5 MPa, Protocol: Ethernet I/Pâ„¢
Thread: NPT, Port: 3 [3/8" (2000, 3000)], Stations: 8 Stations, Pressure: 0.9 MPa, Protocol: Ethernet I/Pâ„¢
Thread: NPT, Port: 3 [3/8" (2000, 3000)], Stations: 6 Stations, Pressure: 0.5 MPa, Protocol: Ethernet I/Pâ„¢
regulator ITV2050-212S-X26 SMC REGULATOR SMC REGULATOR VBA UNLOCK LOCK RESET SET VE VY G 1 2 3 Stations AL Manifold base (3 stations) IITV20-02-3 (1) 1set (3 station manifold base part no.) 1set (Electro-pneumatic regulator part no.) (2) IITV20-02-3 ITV2030-312S-X26 P398020-13 ITV2050-212S-X26 1set (Blanking plate assembly part no.) 1set (Electro-pneumatic regulator part no.) (2) The
regulator ITV2050-212S-X26 SMC REGULATOR SMC REGULATOR VBA UNLOCK LOCK RESET SET VE VY G 1 2 3 Stations AL Manifold base (3 stations) IITV20-02-3 (1) 1set (3 station manifold base part no.) 1set (Electro-pneumatic regulator part no.) (2) IITV20-02-3 ITV2030-312S-X26 P398020-13 ITV2050-212S-X26 1set (Blanking plate assembly part no.) 1set (Electro-pneumatic regulator part no.) (2) The
Occupied byte Unit Unit part number Input Output EX600-SEN (32 outputs) 0 4 EX600-SEN (24 outputs) 0 3 SI unit EX600-SEN (16 outputs) 0 2 EX600-SEN (8 outputs) 0 1 EX600-DXB (8 inputs) 1 0 EX600-DXC (8 inputs) 1 0 EX600-DXC1 (8 inputs)(with open circuit detection) 1 0 Digital input unit EX600-DXD (16 inputs) 2 0 EX600-DXE (16 inputs) 2 0 EX600-DXF (16 inputs) 2 0 EX600-DYB (8 outputs) 0 1
To set pressure at 0.3MPa by ITV2030(for 0.5MPa type) (0.3MPa/0.5MPa)40952457DEC999(HEX) Pressure of 0.3MPa is set by sending input data of 999 to the electro-pneumatic regulator through the master PLC. 9 - Communication data allocation Set target value (from PLC to ITV) Resolution : 12bit (100%F.S.), Occupied byte : 2 Byte Target value (O area) Target value (Lower 12 bits) 12bit 0 0 0 0
To set pressure at 0.3MPa by ITV2030(for 0.5MPa type) (0.3MPa/0.5MPa)40952457DEC999(HEX) Pressure of 0.3MPa is set by sending input data of 999 to the electro-pneumatic regulator through the master PLC.
To set pressure at 0.3MPa by ITV2030( for 0.5MPa type) (0.3MPa / 0.5MPa)1023614 A pressure of 0.3MPa is set by sending input data of SET 614 to the electro-pneumatic regulator through the master PLC. Set pressure F. S. Set dat a Pressure 100% 75% 50% 25% 0% 0 256 512 767 1023 Input data 7 - Communication protocol The character-code used to communicate is ASCII.
To set pressure at 0.3MPa by ITV2030(for 0.5MPa type) (0.3MPa/0.5MPa)40952457DEC999(HEX) Pressure of 0.3MPa is set by sending input data of 999 to the electro-pneumatic regulator through the master PLC. 9 - Communication data allocation Bellow shows in the case of node address "1".
4 0 N 2 B S X80 2 0 3 0 ITV 33 DeviceNet compatible Model 2000 type 3000 type 2 3 Thread type Pressure range Rc(PT) NPT NPTF G(PF) Nil N T F Cable connector type 0.005 to 0.1MPa 0.005 to 0.5MPa 0.005 to 0.9MPa 1 3 5 Without Straight type 3m Nil S Option (bracket) Port size Without bracket Flat bracket L-bracket Nil B C 1/4 3/8 2 3 Specifications ITV2050 ITV3050 ITV2030 ITV3030 ITV2010 ITV3010
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com E SMC REGULATOR 2 OUT P G Connection thread type MPa IR N F PT NPT PF SUP 2 VEX G Manifold base (3 stations) 1 2 3 AMR IITV20-02-3 ITV2030-311S-X26 P398020-13 ITV2050-212S-X26 1 set (3 station manifold base part no.) 1 set (Electro-pneumatic regulator
BODY ASSEMBLY (KT-ITV2030-3R), INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, 21, IT2000 NO SIZEPART, 0.3784 lb
Part Number Description: CABLE(ITV2030-31N3L3-DIH00494) Product Line: I Product Line Description: INSTRUMENTATION Family Code: 823 Family Description: IT2000/ITV2000 E/P REGULATOR Class Code: 1X Part Code: 1 Reference Code: J Click here to report information errorImage shown may not match exact part number
Bit BYTE 64 (Maximum) Value The Bits 49 54 56 32 30 33 30 2D 49 4C 32 42 4E (hexadecimal number) indicate "ITV2030-IL2BN." (ASCII code) 20 - Setting using buttons ! Caution If the incorrect key is pressed or incorrect information is displayed during setting, power must be shut off and the procedure started again.
Product ID ITV1010-IO-X395 *1 ITV1030-IO-X395 *1 ITV1050-IO-X395 *1 ITV2010-IO-X395 *1 ITV2030-IO-X395 *1 ITV2050-IO-X395 *1 ITV2090-IO-X395 *1 ITV3010-IO-X395 *1 ITV3030-IO-X395 *1 ITV3050-IO-X395 *1 ITV3050-IOF3N-DIT00375 *1: This becomes product ID added since FW Ver1.2.
Setting method Ex) In case that setting pressure is 0.3MPa on ITV2030(0.5MPa specification). (0.3MPa/0.5MPa) 1023 = 614 (Decimal) Binary data of 614( Decimal) is 10 0110 0110.
1A-X2 126 (Includes controller & connectors) (Includes controller & connectors) 110 100 29.5 Operating Pressure to 0.5MPa, Operating Temperature to 60C Media 2000 (41) 51 43 ( 100C coming soon ) 128.5 226.5 93 81.5 54 30 15 81.5 54 30 15 4 x M4 x 4 Mounting Holes For closed-loop liquid flow control above 3000 ml/min, SMC recommends the following combination. 4 x M4 x 4 Mounting Holes 20 ITV2030
For example, for the ITV2030 (0.5 MPa type), to set the pressure to 0.3 MPa, send (0.3 MPa/0.5 MPa) × 4095 = 2457 (DEC) = 999 (HEX) data “999” from the master PLC to the regulator.
Note) DEC is decimal, and HEX is hexadecimal.
③ ITV series CC-Link compatible products come with Bus adapters.
The part number of the Bus adapter is “EX9-ACY0-MJ.”