Piping: G1/4, ISO1179, Output: 67 [PNP Open Collector 2 Outputs (Pin no.: 2,4)], Display Unit: -, Option 1: -, Option 2: -
Piping: G1/4, ISO1179, Output: 27 [NPN Open Collector 2 Outputs (Pin no.: 2,4)], Display Unit: -, Option 1: -, Option 2: -
Piping: G1/4, ISO1179, Output: 65 [PNP Open Collector 1 Output (Pin no.: 4)], Display Unit: -, Option 1: -, Option 2: -
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Operating Humidity Range(%): 35~85, Number of Inputs: 1, Number of Outputs: 2, Power Supply Type: DC, Power Supply Voltage(V): [12 to 24] 12 to 24 ±10%, Liquid contact parts material: Resin + Metal, Display: Digital, Drive Component: Digital, Lamp: Presence, Acquired Standards: CE, Protection Structure: IP67, Unit Specifications: SI unit fixed, Bracket: None, Calibration Certificate included: N/A,
(%): 35~85, Number of Inputs: 1, Number of Outputs: 2, Power Supply Type: DC, Power Supply Voltage(V): [12 to 24] 12 to 24 ±10%, Liquid contact parts material: Resin + Metal, Display: Digital, Drive Component: Digital, Lamp: Presence, Acquired Standards: CE, Protection Structure: IP67, Unit Specifications: With unit conversion function, Bracket: None, Calibration Certificate included: N/A,
Piping: G1/4, ISO1179, Output: 65 [PNP Open Collector 1 Output (Pin no.: 4)], Display Unit: P [Pressure Unit: PSI (Initial Value), With Unit Display Switching Function], Option 1: L [Lead Wire with M12 Connector (5m), Right-Angled], Option 2: With Bracket
Piping: G1/4, ISO1179, Output: 65 [PNP Open Collector 1 Output (Pin no.: 4)], Display Unit: Fixed SI Unit, MPa, Option 1: None, Option 2: With Bracket
Piping: G1/4, ISO1179, Output: 65 [PNP Open Collector 1 Output (Pin no.: 4)], Display Unit: P [Pressure Unit: PSI (Initial Value), With Unit Display Switching Function], Option 1: None, Option 2: With Bracket
Piping: G1/4, ISO1179, Output: 43 [NPN Open Collector 1 Output (Pin No.:4)+PNP Open Collector 1 Output (Pin no.:2)], Display Unit: With Unit Display Switching Function, Option 1: L [Lead Wire with M12 Connector (5m), Right-Angled], Option 2: With Bracket
Piping: G1/4, ISO1179, Output: 43 [NPN Open Collector 1 Output (Pin No.:4)+PNP Open Collector 1 Output (Pin no.:2)], Display Unit: P [Pressure Unit: PSI (Initial Value), With Unit Display Switching Function], Option 1: -, Option 2: -
Piping: G1/4, ISO1179, Output: 43 [NPN Open Collector 1 Output (Pin No.:4)+PNP Open Collector 1 Output (Pin no.:2)], Display Unit: P [Pressure Unit: PSI (Initial Value), With Unit Display Switching Function], Option 1: L [Lead Wire with M12 Connector (5m), Right-Angled], Option 2: With Bracket
Piping: G1/4, ISO1179, Output: 65 [PNP Open Collector 1 Output (Pin no.: 4)], Display Unit: P [Pressure Unit: PSI (Initial Value), With Unit Display Switching Function], Option 1: -, Option 2: -
Piping: G1/4, ISO1179, Output: 43 [NPN Open Collector 1 Output (Pin No.:4)+PNP Open Collector 1 Output (Pin no.:2)], Display Unit: With Unit Display Switching Function, Option 1: L [Lead Wire with M12 Connector (5m), Right-Angled], Option 2: -