Model A B C D Y Y A B C D Flat Model ZPT10D-6-A10 10 12 15 24 6 Flat with ribs U C ZPT13 -6-A10 U C ZPT16 -6-A10 U C ZPT16D-6-A10 ZPT10 -6-A10 16 18 16 25 7 10 12 15 12 21 1.7 1.8 3 13 Dimensions by Stroke 16 18 12.5 21.5 1.2 3.5 10 16 G Model Dimensions by Stroke E F E F 10, 13 16 ZPTD10-6-A10 35.5 73.5 23 36.5 74.5 G Model E F E F ZPTD20-6-A10 45.5 111.5 46.5 112.5 51 U C ZPT 20-6-A10 U
Action D B T Port thread type Double acting Double acting with spring loaded Single acting (Spring extend) 20 to 50 Nil TN TF Rc NPT G Note) TF for 20 indicates M5.
Width across flat Effective area (mm2) Connection thread Rc Weight (g) d L1 L2 M Model H2 H1 H2 H1 I.D. 2.5 3 4 6 7.5 8 9 10 13 d KFG2F0425-02 KFG2F0403-02 KFG2F0604-02 KFG2F0806-03 KFG2F1075-03 KFG2F1008-03 KFG2F1209-03 KFG2F1210-03 KFG2F1613-04 4 4 6 8 10 10 12 12 16 1.8 2.3 3.3 5.3 6.8 7.3 8 9 12 1.6 2.6 6 17 30 35 45 57 101 1/4 1/4 1/4 3/8 3/8 3/8 3/8 3/8 1/2 17 8 25.9 24 16.4 5 17 19
6 02 ( ) 1 4 02 ( ) 03 ( ) 04 ( ) 02 ( ) 03 ( ) 04 ( ) Port no.
6 10.4 14 (13) AS221FSG-01-08 (S) 8 13.2 22.4 29.5 14.2 15 (14) AS221FSG-01-10 (S) 10 15.9 25.3 32.4 15.6 16 (15) AS221FSG-02-23 (S) 3.2 12 19.1 26.2 19.1 43.9 42.4 40.8 39.3 13.3 20 21.5 6.5 15 1/8 13 (12.7) 7.2 20.9 30.2 (30.3) 22.6 49.7 48.3 44.2 42.8 13.3 21.5 24 7.8 16.2 23 (24) AS221FSG-02-04 (S) 4 8.2 AS221FSG-02-06 (S) 6 10.4 23.4 32.7 (32.8) AS221FSG-02-08 (S) 8 13.2 23.9 33.2 (
SWITCHES D-C7, D-C8, D-H7 ACCESSORIES SWITCH BANDS FOR SWITCHES D-B7, D-B8, D-G7, K7 ACCESSORIES SWITCH BANDS FOR SWITCHES D-B5, D-B6, G5, K5 BMA2-020 20 BMA2-025 25 BMA2-032 32 BMA2-040 40 BMA2-050 50 BMA2-063 63 BM1-01 20 BM1-02 25 BM1-32 32 BM1-04 40 BM1-05 50 BM1-06 63 BA-01 20 BA-02 25 BA-32 32 BA-04 40 BA-05 50 BA-06 63 BA-08 80 BA-10 100 Courtesy of Steven Engineering, Inc. !
AD48 AD47 AD38 AD37 Y300 AKM3000-(01) 02 IS1000M-30 Y310-(01) 02 Float type auto drain Y400 AKM4000-(02) 03 IS1000M-40 Y410-(02) 03 02 VHS40-03 04 02 E400-03 04 06 02 IS1000E-4003 04 06 Y44-02 03 Y500 Y600 Spacer Check valve Note 6) Note 7) Pressure switch Note 7) IS1000M-60 IS1000M-50 Y510-(02) 03 Y610-03 (04) Y610-(03) 04 T-interface Note 6) Note 7) Y110-M5 VHS50-06 10 VHS20-01 02 VHS30
M plug connector 2 position double: VZS3250-M(Z)-01 02 3 position closed center: VZS3350-M(Z)-01 02 3 position exhaust center: VZS3450-M(Z)-01 02 3 position pressure center: VZS3550-M(Z)-01 02 DIN terminal 2 position double: VZS3250-D(Z)-01 02 3 position closed center: VZS3350-D(Z)-01 02 3 position exhaust center: VZS3450-D(Z)-01 02 3 position pressure center: VZS3550-D(Z)-01 02 164 (3 position
8 stations 4 stations 02 2 stations 02 2 stations 02 2 stations (2) (2) (2) Applicable up to 20 solenoids.
-02 KPGL08-01 KPGL08-02 KPGL10-02 KPGL10-03 KPGL12-03 KPGL12-04 KPQL04-M5 KPQL04-01 KPQL04-02 KPQL06-M5 KPQL06-01 KPQL06-02 KPQL08-01 KPQL08-02 KPQL10-02 KPQL10-03 KPQL12-03 KPQL12-04 17 21 25 18.5 23.5 27.5 26 30 33 34.5 37 39.5 8 15.3 22 26 15.8 23.2 27.2 24.4 28.4 29.9 31.9 33.1 37.1 8 10 14 8 10 14 12 14 4 10 19 6 12 20 13 21 26 36 38 65 4 4 4 18 10.4 20.7 D1 10 L2 A D2 8 H 6 10 10 19.5
U side D side U D Made to order 24 VDC 12 VDC Nil 12V Total number of ejector/valve stations SUP/EXH block assembly mounting position A, B port size (Valve only) 02 U D side D B U side 2 to 10 stations 2 4 One-touch fitting 6 One-touch fitting C4 C6 Mixed M When creating the mixed specifications, complete the stations table on the right.
(mm)
connector (M): SYJ74-M01 02 01 02 DIN terminal (D): SYJ74-D01 02 M8 connector (WO): SYJ74-WO01 02 VZ VS VFN Applicable cable O.D. 3.5 to 7 Approx. 300 (Lead wire length) 89.6 Max. 10 58 [65] 91.5 84 42.6 62.5 72.7 M8 x 1 45 69.1 [76.1] Approx. 300 (Lead wire length) Pg7 80.6 [82.8] 90.6 70.8 [73] 79.7 72.3 65.8 23 15 23 15 23 15 23 15 48 48 48 48 12 12 12 12 20 20 20 20 54.5 54.5 54.5 54.5
U side Intermediate connector block assembly wiring example D side U side Connector block Intermediate connector block 20 19 20 19 D side 7 7 8 8 5 5 6 6 3 3 4 4 U side D side 2 1 2 1 FREE LOCK SOL.b SOL.a SOL.a SOL.b SOL.b SOL.a SOL.a SOL.b COM COM SOL.a SOL.b SOL.b SOL.a SOL.a SOL.b SOL.b SOL.a Station 3 Station 4 Station 1 Station 2 (Station 4) Double solenoid (Station 3) Double solenoid
) D side 2 6 6 (12) 10 (16) 3 5 5 (10) 9 (12) 4 4 (8) 8 (8) 5 3 (4) 4 (4) Note) The max. number of mounted valves applies to double wiring.
side U side SOL.A 5 Station 5 SOL.B 18 SOL.A 6 Station 6 SOL.B 19 SOL.A 7 Station 7 SOL.B 20 SOL.A 8 Connector terminal no.
side U side SOL.A 5 Station 5 SOL.B 18 SOL.A 6 Station 6 SOL.B 19 SOL.A 7 Station 7 SOL.B 20 SOL.A 8 Connector terminal no.
layout Note 2) (Up to 21 solenoids possible) 20 20 20 stations 20 stations PG: Flat ribbon cable connector (20 pins) PH: Flat ribbon cable connector (10 pins) Connector entry direction Note Symbol Note Symbol Stations Stations 1: Perpendicular connector 2: Lateral connector 02 02 2 stations 2 stations Double wiring Double wiring LOCK FREE FREE 08 04 8 stations 4 stations LOCK 02 02 2 stations
(19) AS221F-02-04(S)A 4 8.2 AS221F-02-06(S)A 6 10.4 23.4 32.7 (32.8) AS221F-02-08(S)A 8 13.2 23.9 33.2 (33.3) 14.2 19 (20) AS221F-02-10(S)A 10 15.9 26.9 36.2 (36.3) 15.6 20 (21) AS321F-02-06(S)A 6 1/4 17 (17.5) 13 13.3 40 (40) AS321F-02-08(S)A 8 13.2 22.7 33 14.2 41 (41) AS321F-02-10(S)A 10 15.9 26.7 37 35.7 15.6 42 (42) AS321F-02-12(S)A 12 18.5 29.7 40 34.5 17 43 (43) AS321F-03-06(S)A 6
1/4 3/8 1/2 02 03 04 VPA300 VPA500 VPA700 2 stations 20 stations 20 Manifold Option Description Part no.