SMC Corporation of America
Elite Part Number Search
Search Results "IP8000-030-BF"

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4-FD MM BZ GB lRY EA BF FY D E W AL FT C B M A K F RT N N FX FZ BY S + Stroke H ZZ + Stroke BW With rod boot 180, 200, 250 BZ BV e BG BE f l 15 h + l 4-MA Effective thread depth MB (To attach eyebolt) ZZ1 + l + Stroke Bore size (mm) Stroke range (mm)

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rc P 4-FD Width across flats KA Width across flats B1 CNA GB Head side cylinder port PH MM CNS FY 0.15 E 0 0.05 BZ BC BF D I CLS H1 CLQ AL C 0.1 FX 0.15 8-J BN FT A K S + Stroke H ZZ + Stroke F FZ NA MLGP BC RLQ MLU e ML1C DZZ + l + Stroke h + l f 8 l

D I H1 AL C0. 1 FX 0. 15 8-J A K S + Stroke H ZZ + Stroke F BN FT FZ NA BC e ZZ + l + Stroke h + l f 8 l With rod boot (mm) Stroke range with rod boot Standard Long stroke Bore size (mm) Stroke range without rod boot Standard Long stroke 20 25 32 40 A AL B1 BC BF BN BP BZ C D E F GA GB GC GK GL GR GQ H1 20 to 200 18 15.5 13 38 38 93 1/8 44.5 14 8 12 2 85 10 (12) 18 5.5 6 4 8 5 to 200 201

FY W AL FT C N N M RT A K 43 B FX FZ BY S + Stroke H ZZ + Stroke With rod boot 75 l 40 15 h + l ZZ1 + l + Stroke (mm) Bore size (mm) Stroke range (mm) 125 140 160 A AL B BA BB BC BF BY BZ C D FT FX FY FZ GA GB GC J 50 47 145 75 18 145 110 136 115 36 14 190 100 230 16 107 58 M14 x 1.5 to 1400 50 47 161 78 18 2 160 110 146 128 36 20 212 112 255 16 114 64 M14 x 1.5 to 1400 56 53 182 95 23

D I H1 AL C0. 1 FX 0. 15 8-J A K S + Stroke H ZZ + Stroke F BN FT FZ NA BC e ZZ + l + Stroke h + l f 8 l With rod boot (mm) Stroke range with rod boot Standard Long stroke Bore size (mm) Stroke range without rod boot Standard Long stroke 20 25 32 40 A AL B1 BC BF BN BP BZ C D E F GA GB GC GK GL GR GQ H1 20 to 200 18 15.5 13 38 38 93 1/8 44.5 14 8 12 2 85 10 (12) 18 5.5 6 4 8 5 201 to 350

DIA BF BF Red lights up when bus failure is detected. SI unit SI unit EX250 : Contact each manufacture about Communication cable and Bus Tee. Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof.

Note 1 Pilot valve unit P565010-7 2 Base seal P56501012-3 IP8000/8100 (2) Base seal 3 Cover seal P56501013 2 Series IP8000/8100 Piping IP8000 / Lever type Double action Single action When the input signal is increased, the stem moves as allow mark. When the input signal is increased, the stem moves as allow mark.

IP8000 E/P positioner is more compact than the IP6000 with improved visibility of the pressure indicator.  Other features include an improved enclosure protection IP65, interchangeable mounting, excellent shock and vibration performance, and a 1/2 split range available by simple span adjustment.  The IP200 cylinder positioner provides accurate and stable positioning of air cylinders.  

IP8000 4 F 50140mm G (A) IP8000/IP8100 5 H IP8100 J 420mADC IP8100 JR 420mADC 6 1 1 ExdBT5 -2060 -2080 ExdBT5 2 IP8000-011-AG 3A90cm B180cm 4 5ABAB (A) 6J 26 13.

-A-10/20-* . 9-1 9.1.2 HRR012/018/024/030-W-10/20-* . 9-3 9.1.3 Refrigerant with GWP reference . 9-5 9.1.4 Communication specification . 9-5 9.2 Outline dimensions . 9-6 9.2.1 HRR012/018-A-10/20. 9-6 9.2.2 HRR012/018-W-10/20. 9-7 9.2.3 HRR024/030-A-20. 9-8 9.2.4 HRR024/030-W-20. 9-9 9.3 Flow Chart . 9-10 9.3.1 HRR012/018/024/030-A-10/20.9-10 9.3.2 HRR012/018/024/030-W-10/20-.9-10 9.4 Cooling

(load power for the valve is not supplied or outside tolerance range) The configuration information registered in the master and the number of output points does not match (BF flashing). RDReceive Data 4 SF 2 Red ON BUS IN: M12 4-pin socket D-coded (SPEEDCON) 1 OFF No.

SF and BF Indicators Yes Over current detection 2 DI (Input signal "n+4") FS LED 3 1 BF SF Description 3 0V (US1) Fieldbus Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.

V +24 V for SI unit operation LED Description 8 Mounting hole Mounting hole for connection to the valve manifold SI0 V 0 V for SI unit operation 4 SF System fault 5 Unused Accessories BF BUS fault Hexagon socket head cap screw 2 pcs.

Check the number of input/output is set correctly. 1 BF LED is lights up Check the power for output (24 VDC) is powered at a specified voltage. Check the power supply voltage for output is above 20 V. Check the input unit is connected after the input port. 2 DIA LED is lights up : Refer to "Operation Manual" for detail of troubleshooting. 22

The HF2-BF series currently includes port sizes of 1/4, 3/8, and 1/2 with flow rates up to 800 L/min.

No change in external dimensions of this product Pump Capacity HRR012/018--10-T/MT 0.6 Circulating fluid pressure [MPa] 0.5 Allowable operating range 0.4 Outlet: 60 Hz 0.3 Outlet: 50 Hz Return port 0.2 Return port (Option Z1) Allowable operating range 0.1 Return port (Option Z) 0 0 10 5 15 20 25 Circulating fluid flow rate [L/min] HRR012/018/024/030-mm-20-MT HRR012/018/024/030-mm-20-T 0.6

ISG121-030 ISG221-030 Stainless steel 316 None 0.02 to 0.35 Cable gland ISA2 ISG121-031 ISG221-031 Stainless steel 316 Yes 0.02 to 0.45 Type A IS ISG130-030 ISG230-030 Brass, Phosphor bronze None 0.03 to 0.4 20a ISG130-031 ISG230-031 Brass, Phosphor bronze Yes 0.03 to 0.6 20b ZSM 0.1 to 1.0 1.5 0.02 ISG131-030 ISG231-030 Stainless steel 316 None 0.03 to 0.4 20c PF2 ISG131-031 ISG231-031

ISG121-030 ISG221-030 Stainless steel 316 None 0.02 to 0.35 Cable gland ISA2 ISG121-031 ISG221-031 Stainless steel 316 Yes 0.02 to 0.45 Type A IS ISG130-030 ISG230-030 Brass, Phosphor bronze None 0.03 to 0.4 20a ISG130-031 ISG230-031 Brass, Phosphor bronze Yes 0.03 to 0.6 20b ZSM 0.1 to 1.0 1.5 0.02 ISG131-030 ISG231-030 Stainless steel 316 None 0.03 to 0.4 20c PF2 ISG131-031 ISG231-031