No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, PACKING MTRL SET HRZ008-L*, REFRIGERATED THERMO-COOLER, 737
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Compressor Set (HRZ008-L/L1), REFRIGERATED THERMO-COOLER, 737
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Tank Assembly for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Condenser Assy for HRZ008-L(1), REFRIGERATED THERMO-COOLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Circulating Pump for HRZ008-L-F, REFRIGERATED THERMO-COOLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Circuit Protector for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Motor Breaker for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Motor Breaker Assy for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Magnetic Contactor for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Magnetic Contactor for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Pump Inverter for HRZ008-L-F, REFRIGERATED THERMO-COOLER, 737
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Pump Inverter for HRZ008-L1-F, REFRIGERATED THERMO-COOLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Compressor for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER, 737
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Tank Cover R for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Tank Cover L for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Tank Insulation for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER
CRATE FOR HRZ008, HRZ004, AMAT, REFRIGERATED THERMO-COOLER, 737, 149 lb
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Casters (496, 498, HRZ008-L/L1, & HRZD), REFRIGERATED THERMO-COOLER
Ht BY IA 43 25 40 Max.Wc 36 35 13 D 30 Width across flats K Ws Width across flats 44 Clevis width CLK1A: 16.5 R15 0.050 0.093 +0.027 0 Shaft: 12d9 Hole: 12H8 F +0.3 0 +0.4 0 CLK1B: 19.5 Z + Stroke S + Stroke 1.5 27 2 40 57 97 ZZ + Stroke Approx.
Ht BY IA 43 25 Max.Wc 40 36 35 13 D 30 Width across flats K Ws Width across flats 44 R15 Clevis width CLK1A: 16.5 0.050 0.093 +0.027 0 Shaft: 12d9 Hole: 12H8 F +0.3 0 +0.4 0 CLK1B: 19.5 Z + Stroke S + Stroke 1.5 27 2 40 57 97 ZZ + Stroke Approx.