Cooling Capacity: Cooling Capacity: 3800W/4200W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: Applicabe to DI Water Piping

Cooling Capacity: 012 [1000/1200, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: Applicabe to DI Water Piping

Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: Applicabe to DI Water Piping

Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: Applicabe to DI Water Piping

Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: Applicable to Deionized Water Piping


Alarm code “AL28” (pump maintenance) will be activated every 20,000 hours (every 8000 hours for option “T” and the HRS050/060) of operation.
Consider requesting maintenance from a maintenance company.
We can recommend service providers if needed.


For the HRS012/018/024/030 option “T” (high-pressure pump) and the HRS050/060, after 8000 hours, alarm code “AL28” (pump maintenance) will be activated.
We recommend that you check for leaks and replace the mechanical seal at this time. Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.

Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030; SMC recommends Bypass Piping Set HRS-BP004 for Models HRS-040, HRS050

Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030; SMC recommends Bypass Piping Set HRS-BP004 for Models HRS-040, HRS050

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values. 

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc

Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: None

Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: None

Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: None