Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BT (B + T)
Type: -, Cooling Method: -, Cooling Capacity: 2,600/3,200 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / High pump head specification
25 25 30 35 45 60 12,5 12 15 16 20,5 20,5 20 20 130 145 155 170 190 205 245 280 7 9 9 9 12 14 16 18 10 12 12 16 16 20 25 30 65 75 80 90 110 140 164 204 15 18 18 23 23 28 30 35 142 160 170 190 210 230 275 315 45 52 60 70 90 110 130 170 26 28 32 40 50 60 70 90 26 28 32 40 50 60 69,5 89,5 9 12 12 16 16 20 25 30 32 36 45 50 63 75 90 115 10 11 12 13 15 18 15 20 3,2 3,2 3,2 3,2 4,5 6 9 11 144
-12 BT-12 BT-16 BT-18A BT-20 10 10 10 10 10 CJP 17 17 17 17 17 CJ2 D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL D-A3/A44 D-G39/K39 BS1-125 BS1-140 BS1-200 BS1-160 BS1-180 7.5 13 12 7 8 CM2 D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL CG1 D-F5/J5/F5W D-J59W/F5BAL D-F5NTL/F59F BS4-125 BS4-125 BS4-160 BS4-180 BS4-200 5 5 5.5 6 6 MB D-G39/K39 [Stainless Steel Mounting Screw Kit] 11 11 10 10 10
247 280 292 Z 101 111 115 138 144 Z 93 103 107 129 135 ZZ 221 231 239 271 283 40 50 63 80 100 15 0.032 0.059 15 0.032 0.059 18 0.032 0.059 25 0.040 0.073 25 0.040 0.073 38 20 20 20 24 24 45 50 57 69.5 79.5 23 23 28 35 43 85 95 110 140 162 77.5 87.5 102 124.5 144.5 115 125 146 190 212 8 0 0 0 0 18 18 18 20 20 43.5 49 63 73 The minimum stroke of the one with rod boot is 20 mm or more. 10-15
, making it possible to hold a cylinder intermediate stopping position for an extended time.
Nil S n L Auto switch type Nil Without auto switch Cylinder bore size (stroke mm) Refer to the table below for auto switch part numbers. 6 8 12 16 20 25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Nil F R Note 2) Standard With buffer With
40 10 95 17 56.5 20 13 15 12 11 to 600 35 32 86 27 115 1/4 1/4 64 16 25 20 40 10 102 17 67 20 18 12 15 11 to 600 40 37 102 32 139 1/4 1/4 78 20 31.5 25 52 14 123 21 83 20 23 18 17 13 to 750 40 37 116 41 160 1/4 1/4 92 25 35.5 30 52 14 144 21 98 22 25 20 19 16 to 750 (mm) Bore (mm) 40 50 63 80 100 K J KA L MM N P Q H S T U V W Z ZZ RR 6 M8 X 1.25 14 30 M14 X 1.5 27 1/4 37 to 39.5 51 10 153
MG Bore size (mm) 40 Bore size (mm) 40 Model Model 50 63 80 100 50 63 80 100 MGP D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5NTL D-F5BAL/F59F D-A3/A44 D-G39/K39 D-B5/B6 D-B59W D-G5/K59 D-G5W/J59W D-G5BAL D-G59F/G5NTL D-A3C/A44C D-G39C/K39C MGQ BT-04 BT-04 BT-06 BT-08 BT-08 BA-04 BA-05 BA-06 BA-08 BA-10 MGG MGC BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M BA3-040 BA3-050 BA3-063 BA3-080 BA3-100 To order
MGC Bore size (mm) 40 Bore size (mm) 40 Model Model 50 63 80 100 50 63 80 100 MGF D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5NTL D-F5BAL/F59F D-A3/A44 D-G39/K39 D-B5/B6 D-B59W D-G5/K59 D-G5W/J59W D-G5BAL D-G59F/G5NTL D-A3C/A44C D-G39C/K39C CY1 BT-04 BT-04 BT-06 BT-08 BT-08 BA-04 BA-05 BA-06 BA-08 BA-10 MY1 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M BA3-040 BA3-050 BA3-063 BA3-080 BA3-100 To order
For detailed specifications, refer to page 10-20-1.
mm Lead 150 Slide screw 20 mm Lead 500 10 mm Lead Ball screw Horizontal specification Maximum speed 1000 600 500 930 740 20 mm Lead 100W mm/s 500 Slide screw 20 mm Lead 180 10 mm Lead Ball screw 100W Nm Rated thrust 90 20 mm Lead 50 Slide screw 20 mm Lead Rolled 0.05 Repeatable positioning accuracy Ball screw Ground 0.02 mm 0.1 Rolled Slide screw Motor output Horizontal specification
The Volume Flow of 9.44 l/min applies to an element (Valve, fining, tub etc.) with an equivalent orifice "S" of 1 mm'. lf an lement has for example an "S' ot 4,5 mm', the flow would be 4.5 times higher, in this case 4.5 . 54.44 limin = 245 Umln Example 2: Given an element wilh an 'S'ol 12 mm", a working pressure of 7 bar and an air consumption ot 600 ymin.
The Volume Flow of 9.44 l/min applies to an element (Valve, fining, tub etc.) with an equivalent orifice "S" of 1 mm'. lf an lement has for example an "S' ot 4,5 mm', the flow would be 4.5 times higher, in this case 4.5 . 54.44 limin = 245 Umln Example 2: Given an element wilh an 'S'ol 12 mm", a working pressure of 7 bar and an air consumption ot 600 ymin.
When in the locked state, do not apply a load accompanied by an impact shock, strong vibration or turning force, etc. Use caution, because an external action such as an impacting load, strong vibration or turning force, may damage the locking mechanism or reduce its life. 2. Consider stopping accuracy and the amount of over-run when an intermediate stop is performed.
106 120 17 20 The minimum stroke with rod boot is 30 mm or more.
Cooling Capacity: 030 [Cooling Capacity: 2500/2900 W (50/60 Hz)], Pipe Thread: N (NPT with PT-NPT Conversion Fitting Set), Option: None
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.