of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Electric Conductiviy Sensor - HRS012
For the HRS012/018/024/030 option “T” (high-pressure pump) and the HRS050/060, after 8000 hours, alarm code “AL28” (pump maintenance) will be activated.
We recommend that you check for leaks and replace the mechanical seal at this time. Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.
For the HRS012 to 060 and the HRSE series, alarm code “AL29” (fan motor maintenance) will be activated every 20,000 hours of operation (Note 1). Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.
This is an accessory for the HRS012 to 060.
If it is lost or damaged, it can be ordered as an individual part.
The default setting for alarm code “AL09” is continued operation for the HRS012 to 060.
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: J (Automatic Water Supply Function)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: T (High-pressure Pump)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: BJMW
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: Automatic Water Supply Function
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: High-pressure Pump
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: Earth Leakage Breaker
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: BJMW
40 12, 16, 20 25, 32, 40 50, 63, 80 100 10, 16 20, 25 32 6, 10 15, 20 25, 32 6, 10 15, 20 25, 32 12, 16 20, 25 32, 40 20, 25, 32 40, 50, 63 80, 100 32, 40 50, 63 80, 100 20, 25, 32 40, 50, 63 80, 100 20, 25 32, 40 50 6, 10 16 6, 10 16, 20 10, 15 25 Bore size (mm) 5 to 50 mm/s 7 to 50 mm/s 5 to 50 mm/s 5 to 50 mm/s Piston speed Air cushion on both ends Shock absorber (CX2: Option) Rubber
mA, 4 to 20 mA 12 bit resolution Input signal range 10 to 10 V, 5 to 5 V 20 to 20 mA 16 bit resolution EX600-AXA 15 V 22 mA Note 2) Max. rated input signal 50 100 k Input impedance 0.05% F .S.
Pn081 Pn100 2 Speed Loop Gain 10 to 20 0.1 Hz 400 Immediately Tuning 2 Speed Loop Integral Time Constant Pn101 15 to 51200 0.01 ms 2000 Immediately Tuning Pn102 2 Position Loop Gain 10 to 20 0.1/s 400 Immediately Tuning Pn103 2 Moment of Inertia Ratio 0 to 20 1% 100 Immediately Tuning 5.8.1 Pn104 2 2nd Speed Loop Gain 10 to 20 0.1 Hz 400 Immediately Tuning 2 2nd Speed Loop Integral Time
0.035 0.10 0.04 0.030 0.08 MXS12-100 MXS12-75 MXS12-50 MXS12-75 0.03 0.025 MXS12-30 MXS12-40 MXS12-50 MXS12-75 MXS12-20 MXS12-10 MXS12-100 MXS12-40 MXS12-30 MXS12-20 Table deflection mm Table deflection mm Table deflection mm 0.06 0.020 0.02 MXS12-100 MXS12-10 0.015 0.04 MXS12-50 MXS12-40 MXS12-30 0.010 0.01 MXS12-20 MXS12-10 0.02 0.005 20 40 60 80 100 120 0 0 0 20 40 60 80 100 120 60 20
This allows for viable connections to take place without necessarily specifying whether the manifold station is double, single, or mixed wiring. 19 20 19 20 19 20 19 20 19 20 19 20 19 20 19 20 COM Station 1 Double wiring Station 2 Single wiring Station 3 Double wiring Station 4 Single wiring Dual 3-port valves, 4 positions VQC1000/2000 (Rubber seal only) Model A side B side JIS symbol Two