L k Imaginary stroke L' = (Stroke) + k + L k: Distance between the center and end of the plate 6 (Example) q When using CXSJM6-10 and L = 15 mm: Imaginary stroke L' = 10 + 2.75 + 15 = 27.75 Therefore, the graph used for your model selection should be the one for CXSJM6-30 6 ). 2.75 mm 10 4 mm 15 5 mm 20 6 mm 25 w When using CXSJL25-50 and L = 10 mm: Imaginary stroke L' = 50 + 6 + 15 = 71
L k Imaginary stroke L' = (Stroke) + k + L k: Distance between the center and end of the plate 6 (Example) q When using CXSJM6-10 and L = 15 mm: Imaginary stroke L' = 10 + 2.75 + 15 = 27.75 Therefore, the graph used for your model selection should be the one for CXSJM6-30 6 ). 2.75 mm 10 4 mm 15 5 mm 20 6 mm 25 w When using CXSJL25-50 and L = 10 mm: Imaginary stroke L' = 50 + 6 + 15 = 71
K V 1 10 XLA S P1P2 XL XL Conductances combined When each of the separate conductances are given as C1, C2 and Cn, the composite conductance C is expressed as: C=1/(1/C1+1/C2++1/Cn) when in series, and C=C1+C2++Cn, when in parallel.
K V 1 10 XLA S P1P2 XL XL Conductances combined When each of the separate conductances are given as C1, C2 and Cn, the composite conductance C is expressed as: C=1/(1/C1+1/C2++1/Cn) when in series, and C=C1+C2++Cn, when in parallel.
For further details, refer to mounting positions under Replacement heaters/Part Nos. on page 46. 24 High Vacuum Angle Valve Series XLD, XLDV Dimensions (mm) 1in=25.4mm XLDV-25/With solenoid valve 11 C Fn (KF flange) Fb (K flange) C Port R (exhaust port) K K 2.5 41.5 Initial exhaust solenoid valve Main exhaust solenoid valve G A B 8 10.5 Port P (pressure port) A Max 10.5 (except connector
For further details, refer to mounting positions under Replacement heaters/Part Nos. on page 46. 24 High Vacuum Angle Valve Series XLD, XLDV Dimensions (mm) 1in=25.4mm XLDV-25/With solenoid valve 11 C Fn (KF flange) Fb (K flange) C Port R (exhaust port) K K 2.5 41.5 Initial exhaust solenoid valve Main exhaust solenoid valve G A B 8 10.5 Port P (pressure port) A Max 10.5 (except connector
Conductances combined When each of the separate conductances are given as C1, C2 and Cn, the composite conductance C is expressed as: C=1/(1/C1+1/C2+...1/Cn) when in series, and C=C1+C2+...Cn, when in parallel.
Dimensions Panel mount union reducing: LQ1P-R Panel thickness (Max. t) J W1 W2 M1 M2 B side A side H2 H1 E2 E1 L1 L2 Class 4 and 5 Panel hole diameter K Metric Size Model A side B side E1 E2 H1 H2 J K L1 L2 M1 M2 Min. port size t W1 W2 Applicable tubing O.D.
G Za2 D2 Ea Ea Eb Eb 4-MM E1 E1 E2 E2 C2 P Q2 Section Za2 detail (Adjustable range) B2 F2 D G Section Z detail (Adjustable range) F B3 B2 B1 C1 Zb2 JJ B F Z H K2 Counter bore depth H H L Thread length A2 Section Za2 detail (Adjustable range) A A 2 x 2 x LD J C Mounting direction (1) Mounting direction (2) C2 (mm) (mm) Adjustable range Applicable cylinder MY1B25 MY1B32 MY1B40 Mounting direction
direction (2) C2 C K 20 20 JJ M8 x 1.25 M10 x 1.5 LD 11 14 L 7.5 9.5 E4 2.5 2.5 P 16 19 Q E3 2.5 2.5 Model MY-J50 MY-J63 Applicable bore size MY1B50 MY1B63 (mm) 8 9.5 Mounting direction (2) Common G H 3.2 4.5 4.5 Applicable bore size Model D J 35 40 47 MM 5.5 6.5 6.5 A 63 76 92 B C 39 47 56 F 100 124 144 MY1B25 MY1B32 MY1B40 MY-J25 MY-J32 MY-J40 40 55 74 78 94 112 60 80 100 F Mounting direction
Note 2) The direction of rod end width across flats (K) differs depending on the products.
: Moment center position distance compensation amount My L1 A2 L3 C2 (mm) B2: Moment center position distance compensation amount MXW8 MXW12 MXW16 MXW20 MXW25 23 29 37 49 63 A2: Moment center position distance compensation amount Mr (mm) (mm) W Mp MXW8 MXW12 MXW16 MXW20 MXW25 39 48 58 75 97 MXW8 MXW12 MXW16 MXW20 MXW25 10 10 14 20 28 W W 8-7-2 3 Long Stroke Slide Table Series MXW Dynamic
: Correction value for moment center distance L1 A2 L3 C2 My (mm) A2: Correction value for moment center distance MXW 8 MXW12 MXW16 MXW20 MXW25 23 29 37 49 63 B2: Correction value for moment center distance (mm) Mr (mm) W Mp 10 10 14 20 28 W MXW 8 MXW12 MXW16 MXW20 MXW25 39 48 58 75 97 MXW 8 MXW12 MXW16 MXW20 MXW25 W Dynamic moment Moment due to impact of load at end of stroke.
BM Bellows type with groove UM Flat type with groove KJH C2 06 Pad diameter Applicable tubing O.D. 63 63 80 80 04 4 06 6 03 5/32" 07 1/4" When changing the pad diameter, replace also the plate together. !
Type: Pressure Monitor, Sensor, Monitor Structure: Integrated, Output Method: Analog, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Pressure Resistant(kPa): 100, Operating Temperature Range(°C): 18~28, Response Differential(kPa): ±3, Pipe Connection Direction: Back, Plumbing Thread Nominal: [1/4] 1/4, Rated Pressure Range(kPa): -100 to 0, Compatible Fluid: Air,
Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: 02 (R 1/4), Option: None, Attachment: C (Clear Cover w/o Protrusion, is not Removable)
) [ ] lamp Lights up when AL.01 Tank level drop failure or AL.02 Tank level dropalarm is generated.
C37 Series 200 Symbol Port size PB 300 SUS M5 01 02 M5 1/8 (6A) 1/4 (8A) Thread type Nil F N Rc G NPT Piping to 3 Port Valve N.O. Port Caution Socket Electricity 1. Surge voltage A high voltage which is momentarily generated in the shut-off unit by shutting off the power. Cover Others 1. Material NBR: Nitrile rubber FKM: Fluoro rubber = FPM Trade names: Viton, Dai-El, etc.
Materials Thread type Symbol Nil A G H Manifold material Seal material NBR FKM NBR FKM Rc G NPT Nil F N Brass 1 D side 2 3 4 5 U side Stainless steel OUT port size Stations Series 20 Port size M5 1/8 (6A) 1/4 (8A) Symbol 02 : 10 2 stations : 10 stations 30 10 M5 01 02 Note) IN port sizes are as follows. 10: 1/8 (6A) 20: 1/4 (8A) 30: 3/8 (10A) How to Order Valves (for Manifold) VDW 2 3 5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Performance/Specifications General specifications LC5-1-T1-02 Part no.