parallel L Left side parallel Symbol Type NZ Mounting type Z NY Mounting type Y NX Mounting type X NW Mounting type W NV Mounting type V NU Mounting type U NT Mounting type T NM1 Mounting type M1 NM2 Mounting type M2 * Refer to the applicable stroke table. w Size 25 32 40 Applicable Stroke Table : Standard Stroke [mm] Model 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850
MODE B6 MODE Load Load B7 BUSY B7 BUSY Load Load B8 AREA B8 AREA Load Load B9 SETON B9 SETON Load Load B10 INP B10 INP Load Load B11 SVRE Load B11 SVRE Load Load B12 *ESTOP Load B12 *ESTOP *ALARM B13 Load *ALARM B13 Load 14 No.JXC-OMW1019-A 5.
indication) D-A3lC Terminal conduit D-A3/A44 D-G39/K39 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M D-A44C DIN terminal D-G5l/K59 Grommet D-B5/B6 D-B59W D-G5l/K59 D-G5lW/K59W D-G5BAL D-G59F/G5NTL D-G5NT Grommet (With timer) D-G5lW/K59W Grommet (2 color indication) BA-04 BA-05 BA-06 BA-08 BA-10 D-G5BAL Grommet (2 color, Water resistant) D-G59F Grommet (2 color, With diagnostic output) D-G39/K39
D-B5/B6/A3A/A44A/G39A/K39A cannot be mounted on the bore size 20 and 25 cylinder with an air cushion. Note) Adjust the auto switch after confirming the operating condition in the actual setting.
A5 IN3 A5 IN3 A6 DRIVE A6 DRIVE A7 SVON A7 SVON Internal resistance 10 [k] Internal resistance 10[k] A8 NC A8 NC A9 NC A9 NC Main circuit Main circuit Output signal power Output signal power supply supply A10 NC A10 NC 24 VDC 24 VDC DC2(+) B1 DC2(+) B1 DC2(-) B2 DC2(-) B2 BUSY B3 BUSY B3 B4 ALARM B4 ALARM B5 OUT0 B5 OUT0 B6 OUT1 B6 OUT1 Maximum Output current Maximum Output current B7 NC
OUT1<B6> DC2(-)
Stainless steel mounting screw kit: BBA3 for D-B5, D-B6, D-G5, and D-K5 Stainless steel mounting screw kit: BBA4 for D-C7, D-C8, and D-H7 When the type D-H7BAL switch is shipped already mounted on a cylinder, the above stainless steel screws are used.
BBA3: D-B5/B6/G5/K5 types Note 3) Refer to page 1047 for details on the BBA3. When the D-G5BA type auto switch is shipped independently, the BBA3 is attached. Set part no.
Refer to pages starting with 181 for mounting. 3-8H10 depth 10 30 A B Stroke Model LG1H202PC-500-F LG1H202PC-600-F LG1H202PC-700-F LG1H202PC-800-F LG1H202PC-900-F LG1H202PC-1000-F 350 450 550 650 750 850 370 470 570 670 770 870 500 600 700 800 900 1000 95 B 100 95 8-6.2 110 95 20 95 A Positioning Time Guide Positioning time Positioning time (sec.)
Applicable strokes: 150, 250, 350, 450, 550, 650, 750, 850, 950 Example) LJ1H1011SC-150-F2-X2 Allowable Moment (Nm) Allowable dynamic moment Allowable static moment LJ1H10 Model Mounting orientation Load movement direction Pitching Rolling Yawing 10.2 12.8 10.2 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep 2000 a = 1000 L1 (mm) Pitching m : Transfer load (kg) a : Work piece
AM250C to 550C, 650, 850 Mist Separator Drain discharge is possible only manually.
Refer to pages starting with 181 for mounting. 3-8H10 depth 10 30 A B Stroke Model LG1H202PC-500-F LG1H202PC-600-F LG1H202PC-700-F LG1H202PC-800-F LG1H202PC-900-F LG1H202PC-1000-F 350 450 550 650 750 850 370 470 570 670 770 870 500 600 700 800 900 1000 95 B 100 95 8-6.2 110 95 20 95 A Positioning Time Guide Positioning time Positioning time (sec.)
BBA3: For D-B5/B6/G5/K5 BBA4: For D-C7/C8/H7 D-G5BAL/H7BAL switch is set on the cylinder with the stainless steel screws above when shipped.
Elbow fitting assembly (Downward) B4: 4 elbow fitting assembly B6: 6 elbow fitting assembly 5 (EA) 1 (P) 3 (EB) 4 position dual 3 port valve: N.C./N.C. A 4 Back pressure check valve (A) 4 (B) 2 Nil K None A 2 B SOL.b SOL.a 3 (R) 5 (R) Built-in The built-in back pressure check valve type has an effective area approximately 20% smaller.
Elbow fitting assembly (Downward) B4: 4 elbow fitting assembly B6: 6 elbow fitting assembly 5 (EA) 1 (P) 3 (EB) 4 position dual 3 port valve: N.C./N.C. A 4 Back pressure check valve (A) 4 (B) 2 Nil K None A 2 B SOL.b SOL.a 3 (R) 5 (R) Built-in The built-in back pressure check valve type has an effective area approximately 20% smaller.
B6 OUT5 B7 BUSY This terminal is ON during the movement of the electric actuator. (During the positioning operation, etc.). Caution During the pushing operation without movement (no movement but the electric actuator generating the pushing force), BUSY is OFF. BUSY signal stays on for 50ms or longer after operation starts.
Hs 8.5 8.5 Auto switch Auto switch 16 16 A 36.7 B A 38.2 B D-B5, D-B6, D-B59W D-A3, D-G3, D-K3 Approx. Hs Auto switch 36 Approx. Hs 12 Auto switch 24.5 34 SMC AUTO SWITCH SMC AUTO SWITCH A 49 A 33 6.5 B D-G5, D-K5, D-G5W, D-G5BA, D-K9W, D-G59F, D-G5NT D-A44 12 Auto switch Approx. Hs 36 Approx.
B 2 2(B) 4(A) B Elbow fitting assembly (Downward) B4: 4 elbow fitting assembly B6: 6 elbow fitting assembly 1(P) 5(EA) 3(EB) A 4 4 position dual 3 port valve: N.C./N.O.
BBA3: D-B5/B6/G5/K5 types Note 3) Refer to page 1681 for details on the BBA3.
BBA3: For D-B5/B6/G5/K5 BBA4: For D-C7/C8/H7 The above screw made of stainless steel is used for D-H7BAL switch when cylinder mounting is shipped. BBA4 is attached when switch is shipped. 4.9-7 Series REC How to Select Model Selection Procedures Provisional selection accordling to absorbed energy Please refer to graph q.