Operator Piping specification: -F02 After hand tightening, tighten the fitting using a spanner on the flat surfaces of the fitting. The tightening torque must be 4 to 5 Nm. The operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment.
D The setting time from when the pressure applied to the pressure switch reaches the set value, to when the ON-OFF output actually begins working. Delay time setting can prevent the output from chattering. Delay time Shows how precisely the pressure can be displayed or set by the digital pressure switch.
output specifications Example 1) 0.4 MPa setting with 6 stations IRM10-6G-16 Example 2) 0.2 MPa setting 2 pcs., 0.4 MPa setting 2 pcs., 0.8 MPa setting 1 pc. with 5 stations IRM20-5G-021221 AMR Output specifications NPN open collector 1 output PNP open collector 1 output NPN open collector 1 output + Analog voltage output NPN open collector 1 output + Analog current output Symbol A B C D
l~1 "fd" , ,01 R(PT)1IB M5 X 0.8 With One-touch fillings R{PT)1/4 Rc(PT)lIB 03 'I R(PT)318 02 Rc(PT)1/8 R(PT)1/2 Rc{PT)1/4 04 R(PT)lf4 F02 G(PF)118 f03 R(PT)3/8 G(PF)lIB F04 R(PT)112 G(PF)li4 NOI NPT1/8 lO-32UNF N02 NPTl14 NPT1/8 NPT3/8 N03 NPT1/8 NPT1/2 NPTli4 1'04 Needle Valve/Flow Rate Characteristics ASP330F ASP430F 400 6 'E o,7,08,OY; E 06 12 ~300 200 3 'E ( 0 4 % r !
Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: F01 (Screw-in G1/8), VAC: F02 (Screw-in G1/4), EXH: F02 (Screw-in G1/4)
Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: S (-90 kPa), SUP: F01 (Screw-in G1/8), VAC: F02 (Screw-in G1/4), EXH: F02 (Screw-in G1/4)
Port size 02 R1/4 N02 NPT1/4 F02 G1/4 Suffix for actuator* S Hard steel roller R Red Color of push button, selector B Black G Green Y Yellow Construction Non-actuated Actuated Force e u w R port 3 port only Port 2 Port 2 Port 1 Port 1 q t y r Component Parts No.
Body Size: 4 (1/4 Basis), Port Size: F02 [Cylinder Side (R(PT)1/4) Pilot Port (G(PF)1/8)], Applicable Tube OD: Ø6, Lock Nut: J (Round)
Body Size: 4 (1/4 Basis), Port Size: F02 [Cylinder Side (R(PT)1/4) Pilot Port (G(PF)1/8)], Applicable Tube OD: Ø8
Body Size: 4 (1/4 Basis), Port Size: F02 [Cylinder Side (R(PT)1/4) Pilot Port (G(PF)1/8)], Applicable Tube OD: Ø6
Body Size: 4 (1/4 Basis), Port Size: F02 [Cylinder Side (R(PT)1/4) Pilot Port (G(PF)1/8)], Applicable Tube OD: Ø8, Lock Nut: J (Round)
DIN rail is not suitable for port size F02 (G1/4). Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2011 SMC Corporation All Rights Reserved DIN rail mounting screw
DIN rail is not suitable for port size F02 (G1/4). This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenace of such equipment. Only those persons are allowed to perform assembly, operation and maintenance.
Standard specifications Optional specifications Set pressure max. 0.5MPa 3 P P Approx. 133 Set pressure max. 0.9MPa 5 P P Connection Rc(PT) 1/4 02 P P eL-bracket rT-bracket Connection Rc(PT) 3/8 03 P P Connection Rc(PT) 1/2 04 P Bracket B p p Accessories 178 Bracket C p p Connection NPT1/4 N02 p p qAF3000 wAFM3000 eITV2000 Connection NPT3/8 N03 p p Connection NPT1/2 N04 p Connection G(PF) 1/4 F02
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: F02 (G1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: F02 (G1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]
Number of Ports: 3 Port, Body Option: Side Mounting, Port Size: F02 (G 1/4), Actuator Type: 32 (Push Button, Extended), Suffix: R (Red)
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)