Bore Size: 32mm, Stroke: 500mm, Piping Port Position: -, Auto Switch: -, Number: -
SA Y59B MF 200 32 Straight Type Number of auto switches 3-dimensional transfer single unit Bore size 2pcs. 1pc. "n" pcs. Nil S n Auto switch type 15 32 15mm 32mm Nil Without auto switch Refer to the table below for auto switch part numbers. Straight type Stroke Air supply unit Note 1) 200 250 300 350 400 450 500 600 1000 200mm 250mm 300mm 350mm 400mm 450mm 500mm 600mm 1000mm Qty.
177 188 47.3 143.5 to 500 Up to 300 Up to 300 Precautions on Trunnion Style, Flange Style 1.
[mm] Bore size Standard stroke Max. stroke 32 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 2000 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 2000 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 2000 100 25, 50, 80, 100, 125, 160
, 400, 450, 500, 600 Up to 1200 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 MB1 Up to 1800 CA2 Up to 1500 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 125 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800,
Chart (1) 400 st 500 st 600 st 700 st 400 st 500 st 600 st 700 st 10 5 4 300 st 300 st 3 200 st 200 st Load movement time: t (S) 2.
MNB CNA Maximum piston speed: 500 mm/s It can be used at 50 to 500 mm/s provided that it is within the allowable kinetic energy range. (The lock-up cylinder can operate at 50 to 200 mm/s.)
[mm] Bore size Standard stroke Max. manufacturable stroke Stroke range q Stroke range w 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 Up to 1000 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 Up to 1200 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500,
Fluid Air Proof pressure 1.05 MPa CL Maximum operating pressure 0.7 MPa Maximum piston speed: 500 mm/s It can be used at 50 to 500 mm/s provided that it is within the allowable kinetic energy range.
Maximum speed (mm/s) (Example) Find the upper limit of rod end load when an air cylinder of 63 is operated at 500 mm/s.
Standard 32 700 Clevis pin Single knuckle joint 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 Option Double knuckle joint (with pin) 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50 1000 Mounting Brackets/Part No. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 1000 Bore size (mm) 32 40 50 63 80 100 25, 50, 75,
-500 Basic weight1.287 kg Additional weight0.033/50 st Cylinder stroke500 st 1.287 + 0.033 x 500 50 = 1.617 kg Technical Data 1469 A CY3B Series Construction Basic type CY3B6 !
Standard Strokes [mm] Bore size [mm] Standard stroke [mm] 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Note) Intermediate strokes not listed above are produced upon receipt of order.
Calculation of Guide Load Factor 1 Operating Conditions Mounting Orientation Cylinder MY1MW40-500 Average operating speed a 200 mm/s Mounting orientation Horizontal mounting z 1. Horizontal mounting 2. Wall mounting y Wd: Workpiece (500 g) P.1230 x y Wc: MHL2-16D1(795 g) x z Wa: Connection plate t = 10 (880 g) x MY1MW40-500 3. Ceiling mounting 4.
Up to 500 Up to 1000 Up to 600 Up to 1000 Up to 600 Up to 1000 Up to 750 Up to 1000 Up to 750 Note) End boss is machined on the flange for E.
25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 2000 2000 2000 2000 2000 2000 Minimum Stroke for Auto Switch Mounting 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 Refer to Minimum Stroke
Horizontal Operation (Wall mounting) CY1L40 Model 10 (2.48 1.3 x 103 x ST) = 50 Note) Calculate with = 1 for all applications up to 10 300 mmST, 15 500 mmST, 20 500 mmST, 25 500 mmST, 32 600 mmST and 40 600 mmST.
ML2B25 0.3 0.4 0.5 ML2B32 ML2B32 ML2B32 ML2B32 1 0.2 0.3 0.4 0.5 ML2B25 ML2B25 ML2B25 ML2B25 0.2 0.5 0.4 0.3 0.1 0.1 0.2 0.05 0.05 0.1 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s) Dynamic Moment Moment generated by impact load at stroke end Reference formula [Dynamic moment at impact
1000 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 1900 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 1900 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 1900 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 1900 100 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 1900 125 2000 Made to Order (For details, refer to pages