mounting position CY1HT25 6 5 A B Auto switch model CY1HT32 9 6 D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV Note) Operating ranges are standards including hysteresis, and are not guaranteed.
Piping is available from 2 directions. 4 90 Standard Transfer direction Port Port 90 With 50 to 80, the direction of the roller lever is selected in the part number.
(Tolerance 30%) 5.3-20 Reed Switch/Direct Mounting D-90/D-97 Applicable Actuator Series Grommet Lead wire: Parallel cord Series Bore size (mm) CDJP-lD 6, 10, 15 CDU 6, 10, 16, 20, 25, 32 Specifications PLC: Programmable Logic Controller D-90 (Without indicator light) D-90 Auto switch model number Application Relay/IC circuit/PLC AC DC 5V AC DC 12V AC DC 24V Load voltage Max. load current
90 Max. 25 8 16 250 270 Rod flange (F) [mm] Bore size [mm] R TF FB E2 UF W MF 4 x FB 32 32 64 7 50 79 16 10 40 36 72 9 55 90 20 10 50 45 90 9 70 110 25 12 63 50 100 9 80 120 25 12 80 63 126 12 100 153 30 16 100 75 150 14 120 178 35 16 E2 R W MF TF UF 125 90 180 16 Max. 157 Max. 224 45 20 Head flange (G) [mm] Bore size [mm] MF ZF 32 10 130 40 10 145 50 12 155 63 12 170 80 16 190 100 16 205
D-Y7WV 95 90 10 100 D-Y7BAL 125 120 115 20 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.
As a rule, turn the screw an additional 90 after tightening resistance is felt. FB 50 Stroke 66 67.5 109 109 117.5 117.5 121 141 51 Stroke or more 97.5 99 114 114 129 129 148 166 20 25 32 40 50 63 80 100 66 67.5 71.5 78 83 88 102.5 120 19 20 22 22 23 23 24 29 * Other dimensions are same as standard.
38 73 16.5 25.5 90 87 115 10 11 M6 x 1.0 M14 x 1.5 Rc 1/8 7 40 70 100 42 73 16.5 25.5 0.5 1 90 97 115 12 11.5 M8 x 1.25 M20 x 1.5 Rc 1/8 8.7 40 75 122 50 91 18.5 28.5 0.5 1 110 119 138 12 10.5 M8 x 1.25 M20 x 1.5 Rc 1/4 8.7 65 105 145 64 99 20.5 35.5 1 1 120 142 155 PA dimensions are for split from center.
(with indicator light) D-Y69B D-Y7P D-Y59A In-line D-Y69A Perpendicular D-Y7PV Perpendicular D-Y59B Auto switch part no.
MY1 HT MY1 W MY1 W MY1CW (Cam follower guide type) 16, 20 25, 32, 40, 50, 63 MY2C MY2 H/HT MY3A MY3B MY3M B A B A Proper Auto Switch Mounting Position (mm) D-Z7/Z80 D-Y59/Y7P D-Y7W D-Y7BA D-M9V D-M9WV D-M9AV D-A9 D-Y69/Y7PV D-Y7WV D-M9 D-M9W D-M9A Bore size (mm) A B A B A B A B A B 16 20 25 32 40 50 63 74 86 70 90 94 106 90 110 102 118 102 118 97 123 97 123 132 148 132 148 127 153
(same side) 65 60 D-Y59/Y69/Y7P/Y7PV 1 or 2 pcs. (different sides) 20 20 2 pcs. (same side) 65 70 Solid state switch D-Y7W/Y7WV 20 25 1 or 2 pcs. (different sides) 75 70 2 pcs. (same side) D-Y7BAL 20 25 1 or 2 pcs.
With 2 pes (OiHerenl surta~es, 90 % 100 D-V6~ Same sunace). With j ;le. 10 D-Y7PV 10+ 30("2 2) 95 + 301 ";: 4) 100 + 3O In ;: 4) 90+30 D-Y7OWV With n pes. I" = 2. 4. 6. 8.. ) (n = 4.8, 12. 16") (n = 4, 8, 12. 16 .. ) (n = 4, 8, '2, 16 ..) With 2 pes. (DiUerent surfaCfls 115 20 120 ' 25 Same surface), With 1 pc (n '" 2. 4. 6, 8..
(with indicator light) D-Y59B D-Y7P D-Y7PV D-Y69A D-Y59A Perpendicular D-Y69B Auto switch part no.
D-Y69 D-Y7PV 5 2 pcs. 5 1 pc.
Main circuit of switch Main circuit of switch Main circuit of switch D-Y59B D-Y69B D-Y59A D-Y69A D-Y7P(V) Auto switch model OUT Black D0.5 9 10 10 Lead wire length (m) 3 50 53 53 205 83 87 87 DC () Blue D-Y7P, D-Y7PV Dimensions DC (+) Brown D-Y59A, D-Y7P, D-Y59B D-Y69A, D-Y7PV, D-Y69B Mounting screw M2.5 x 4l Slotted set screw Mounting screw M2.5 x 4l Slotted set screw OUT Black Indicator
32 32 43 43 64 64 78 39 43 49 59 71 82 106 +0.058 0 +0.058 0 129 151 185 208 237 263 298 10 10 14 14 22 22 25 33 33 45 45 65 65 75 MB-B03 +0.070 0 MB-B05 +0.070 0 +0.084 0 +0.084 0 +0.084 0 MB-B08 MB-B12 B Rotation 90 Bore size (mm) A B A + B + 90 20 25 32, 40 50, 63 80 35 30 30 35 30 50 50 50 50 35 175 170 170 175 155 A MGJ MGP Clevis Pin MGQ 2 x d Dd9 d Note) Cotter pin Bore size (mm)
Main circuit of switch Main circuit of switch Main circuit of switch D-Y59B D-Y69B D-Y59A D-Y69A D-Y7P(V) Auto switch model OUT Black D0.5 9 10 10 Lead wire length (m) 3 50 53 53 205 83 87 87 DC () Blue D-Y7P, D-Y7PV Dimensions DC (+) Brown D-Y59A, D-Y7P, D-Y59B D-Y69A, D-Y7PV, D-Y69B Mounting screw M2.5 x 4l Slotted set screw Mounting screw M2.5 x 4l Slotted set screw OUT Black Indicator
Minimum Stroke for Auto Switch Mounting (mm) Auto switch Applicable auto switch model No. of auto switches mounted D-Z7, D-Z8 D-Y7W, D-Y7WV D-Y59, D-Y69 D-Y7P, D-Y7PV 5 10 5 10 10 15 1 pc. 2 pcs.
Moreover, due to the fact that bumpers are installed at each end of the piston, overall length is increased by 6mm for 32 and 40, 8mm for 50 and 63, and by 10mm for 80 and 100. 90 90 102 102 124 124 164 200 200 141 145 164 Width across flats Stroke range Bore size (mm) Effective thread length A D Ee11 F G H MB J K MM N P S V W ZZ C B 32 40 50 63 80 100 19.5 27 32 32 37 37 46 52 65 75 95
MK(2) Resistance RS Q G Adjustment dial RS H A RZQ Adjustment dial rotation angle MI W S 90 CEP1 Stopper direction can be changed within 90 CE1 CE2 The stopper lever can be rotated 90.
MK(2) Resistance RS Q G Adjustment dial RS H A RZQ Adjustment dial rotation angle MI W S 90 CEP1 Stopper direction can be changed within 90 CE1 CE2 The stopper lever can be rotated 90.