SMC Corporation of America
Elite Part Number Search
Search Results "CVQL32-25M-M9PWM-5MS"

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, 10 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, 10 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, F29, 10 lb

V O Speed Max. 10ms ON OFF BUSY ON OFF BUSY Max. 30ms Max. 60ms V O Speed Timing for alarm reset Response time with respect to controller input signals ON OFF ALARM -RESET Max. 5ms The following factors exist for delay of response with respect to controller input signals.

Quick response: valve response time: 5ms; vacuum response time: 28ms, Compact & lightweight: 0.101 lbs (46g) single unit weight, Air pressure and release pressure can be adjusted separately, Simple installation and removal, Available with pressure sensor or vacuum pressure switch, VACUUM SWITCH ASSEMBLY, VACUUM SERIES, OTHER OTHER MISC., 21, OTHER NO SIZE RATING, 0.04409 lb

high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Fluid: Air/inert gas, Operating pressure range: 0.01-0.6MPa, Effective area (Cv/effective orifice): 7.2mm 2 -17.5mm 2 (0.4/ 3-1/ 4.8), Coil rated voltage: 12, 24VDC; 100, 110, 200VAC, Response time: 5ms

high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Fluid: Air/inert gas, Operating pressure range: 0.01-0.6MPa, Effective area (Cv/effective orifice): 7.2mm 2 -17.5mm 2 (0.4/ 3-1/ 4.8), Coil rated voltage: 12, 24VDC; 100, 110, 200VAC, Response time: 5ms

Quick response: valve response time: 5ms; vacuum response time: 28ms, Compact & lightweight: 0.101 lbs (46g) single unit weight, Air pressure and release pressure can be adjusted separately, Simple installation and removal, Available with pressure sensor or vacuum pressure switch, Compact Vacuum Unit, Ejector, VACUUM EJECTOR, 60 lb

Quick response: valve response time: 5ms; vacuum response time: 28ms, Compact & lightweight: 0.101 lbs (46g) single unit weight, Air pressure and release pressure can be adjusted separately, Simple installation and removal, Available with pressure sensor or vacuum pressure switch, Compact Vacuum Unit, Vacuum Pump, VACUUM EJECTOR, 60 lb

Conditions and explanations for auto shift function Keep constant pressure for 5ms or more from the close signal of auto shift input. At auto shift input, the pressure at that time is memorized to [C_5] as corrected value, and the switch operates with the value which applied compensation value to setting value. Display indicates [ooo] for approx.1 sec.

(PSE32(T)/35(T)) C_5 1 2 30 1 3 ( ) 2 ( ) 3 4 1 4 -19No.PS-OMG0001CN-H 1OUT1 AP1 (OUT1 1) 2OUT1 OUT1 3OUT1 A1L A1H 4OUT2 P_1H_1(n_1H_1)AP2 (OUT2 1) 5OUT2 OUT2OUT1OUT2 A2LA2H 6 P_3H_2(P_3 n_3) OUT1 (OUT1P_1n_1) P_1A(AB)/4 A H_1(AB)/2 B OUT2P_1n_1H_1P_3n_3H_2 () 1 2 FSt 2 (5R.D.) 3 FSt (3 ) 4 FSC() 5 -20No.PS-OMG0001CN-H 12 5ms [C_5] ooo1 [C_5] OUT1("A1) OUT1P

Ambient temperature 0 to 50C (No freezing) Ambient humidity 35 to 85% RH (No condensation) MTS Square wave noise from a noise simulator (pulse duration 1s) 100V AC line 1500V, 24V DC line 36V I/O line 600V Noise resistance CC Vibration resistance Endurance 10 to 55Hz; amplitude 0.75mm; X, Y, Z for 2 hours each Impact resistance Endurance 10G; X, Y, Z directions, 3 times each Output delay time 5ms

Quick response: valve response time: 5ms; vacuum response time: 28ms, Compact & lightweight: 0.101 lbs (46g) single unit weight, Air pressure and release pressure can be adjusted separately, Simple installation and removal, Available with pressure sensor or vacuum pressure switch VACUUM EJECTOR. VACUUM EJECTOR. 46.00000 lb. M02.

The PFMV5 is a small flow sensor with a rapid response time of less than 5ms.  The PFMV5 series is mountable in a space-saving location since the straight piping length is not required. The PFMV3 voltage monitor for the PFMV5 series can cover a full range of sensors (6 ranges). The sensor connector offers easy connection and removal of wiring.  

The PFMV5 is a small flow sensor with a rapid response time of less than 5ms.  The PFMV5 series is mountable in a space-saving location since the straight piping length is not required. The PFMV3 voltage monitor for the PFMV5 series can cover a full range of sensors (6 ranges). The sensor connector offers easy connection and removal of wiring.  

Quick response: valve response time: 5ms; vacuum response time: 28ms, Compact & lightweight: 0.101 lbs (46g) single unit weight, Air pressure and release pressure can be adjusted separately, Simple installation and removal, Available with pressure sensor or vacuum pressure switch, BRACKET, VACUUM EJECTOR

D-J51: 5ms or less MHZ2 Lead Wire Length MHZJ2 How to specify lead wire length MHQ (Example) MHL2 L D-A73 MHR Lead wire length 0.5m 3m L 5m Z N MHK MHS None Applicable to only connector type switch D-C MHC2 Note 1) Lead wire length Z: 5m Applicable to Reed switch: D-B53/B54, D-C73 (C)/C80C, D-A73 (C) (H)/A80C MHT2 Solid state switch: Made to order (Except D-F9, F9lV, F7lWV) D-A53/A54, D-Z73

D-J51: 5ms or less Change of Lead Wire Color Lead Wire Length Lead wire colors of SMC auto switches have been changed in order to meet Nippon Electric Control Equipment Industries Association Standard No. 402. How to Order Ex.)

Momentary Power Failure ECC-PNAL-***-A 10ms Power Supply ECC-PNAL-***-A 100 240V AC~, +10% -15%, 50 60 Hz Description Code Specication ECC-PNAL-20MT-D, 28.8V DC 5.0 W ECC-PNAL-20MR-D, 28.8V DC 7.0 W ECC-PNAL-20MR-A, 264V AC~ 8.0 W ECC-PNAL-10MT-D, 28.8V DC 2.0 W ECC-PNAL-10MR-D, 28.8V DC 3.0 W ECC-PNAL-10MR-A, 264V AC~ 4.0 W ECC-PNAL-6MR-A, 264V AC~ 3.0 W 24 V DC < 7.0 Amp ECC-PNAL-***-D 5ms

Possible response time settings: 5ms, 20ms, 160ms, 640ms Maximum Minimum 0 OFF The controller equalizes the pressures measured during the specified response time. It then compares the equalized pressure and the set pressure to output switch signals accordingly.