OUT2 setting/(CH1 only) MPa or kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE Normally Open Normally Closed SET SET 8 Series PSE Operation : Initial Setting 4 Response time setting MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE 5ms 20ms 160ms 640ms SET Press SET button.
Function plate (order made) Without vacuum switch Double solenoid Air operated Valve unit Vacuum pump specification full set One pilot Digital Vacuum Switch Specifications/Series ZSE4 ZSE426 65 25 Model NPN open collector 30V, 80mA Analog output 1 to 5V (5%FS) load impedance 1k PNP open collector 80mA Output specifications Indicator light Response frequency Lights up when ON, Green 200Hz (5ms
Primary pressure normal Set value P1 P2 Time ON Switch output 1, 2 OFF Time [ ] Switch output response time when auto shift is input. 5ms or more 10ms or less Hi Auto shift input Lo 3 types of piping Different piping methods are possible to accommodate the installation location.
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire) DIGITAL FLOW SWITCH. Flow Sensor for Air. 10.00000 lb. F29.
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, 10 lb
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, 10 lb
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, F29, 10 lb
V O Speed Max. 10ms ON OFF BUSY ON OFF BUSY Max. 30ms Max. 60ms V O Speed Timing for alarm reset Response time with respect to controller input signals ON OFF ALARM -RESET Max. 5ms The following factors exist for delay of response with respect to controller input signals.
Quick response: valve response time: 5ms; vacuum response time: 28ms, Compact & lightweight: 0.101 lbs (46g) single unit weight, Air pressure and release pressure can be adjusted separately, Simple installation and removal, Available with pressure sensor or vacuum pressure switch, VACUUM SWITCH ASSEMBLY, VACUUM SERIES, OTHER OTHER MISC., 21, OTHER NO SIZE RATING, 0.04409 lb
high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Fluid: Air/inert gas, Operating pressure range: 0.01-0.6MPa, Effective area (Cv/effective orifice): 7.2mm 2 -17.5mm 2 (0.4/ 3-1/ 4.8), Coil rated voltage: 12, 24VDC; 100, 110, 200VAC, Response time: 5ms
high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Fluid: Air/inert gas, Operating pressure range: 0.01-0.6MPa, Effective area (Cv/effective orifice): 7.2mm 2 -17.5mm 2 (0.4/ 3-1/ 4.8), Coil rated voltage: 12, 24VDC; 100, 110, 200VAC, Response time: 5ms
Quick response: valve response time: 5ms; vacuum response time: 28ms, Compact & lightweight: 0.101 lbs (46g) single unit weight, Air pressure and release pressure can be adjusted separately, Simple installation and removal, Available with pressure sensor or vacuum pressure switch, Compact Vacuum Unit, Ejector, VACUUM EJECTOR, 60 lb
Quick response: valve response time: 5ms; vacuum response time: 28ms, Compact & lightweight: 0.101 lbs (46g) single unit weight, Air pressure and release pressure can be adjusted separately, Simple installation and removal, Available with pressure sensor or vacuum pressure switch, Compact Vacuum Unit, Vacuum Pump, VACUUM EJECTOR, 60 lb
Conditions and explanations for auto shift function Keep constant pressure for 5ms or more from the close signal of auto shift input. At auto shift input, the pressure at that time is memorized to [C_5] as corrected value, and the switch operates with the value which applied compensation value to setting value. Display indicates [ooo] for approx.1 sec.
(PSE32(T)/35(T)) C_5 1 2 30 1 3 ( ) 2 ( ) 3 4 1 4 -19No.PS-OMG0001CN-H 1OUT1 AP1 (OUT1 1) 2OUT1 OUT1 3OUT1 A1L A1H 4OUT2 P_1H_1(n_1H_1)AP2 (OUT2 1) 5OUT2 OUT2OUT1OUT2 A2LA2H 6 P_3H_2(P_3 n_3) OUT1 (OUT1P_1n_1) P_1A(AB)/4 A H_1(AB)/2 B OUT2P_1n_1H_1P_3n_3H_2 () 1 2 FSt 2 (5R.D.) 3 FSt (3 ) 4 FSC() 5 -20No.PS-OMG0001CN-H 12 5ms [C_5] ooo1 [C_5] OUT1("A1) OUT1P
Ambient temperature 0 to 50C (No freezing) Ambient humidity 35 to 85% RH (No condensation) MTS Square wave noise from a noise simulator (pulse duration 1s) 100V AC line 1500V, 24V DC line 36V I/O line 600V Noise resistance CC Vibration resistance Endurance 10 to 55Hz; amplitude 0.75mm; X, Y, Z for 2 hours each Impact resistance Endurance 10G; X, Y, Z directions, 3 times each Output delay time 5ms
Quick response: valve response time: 5ms; vacuum response time: 28ms, Compact & lightweight: 0.101 lbs (46g) single unit weight, Air pressure and release pressure can be adjusted separately, Simple installation and removal, Available with pressure sensor or vacuum pressure switch VACUUM EJECTOR. VACUUM EJECTOR. 46.00000 lb. M02.
The PFMV5 is a small flow sensor with a rapid response time of less than 5ms. The PFMV5 series is mountable in a space-saving location since the straight piping length is not required. The PFMV3 voltage monitor for the PFMV5 series can cover a full range of sensors (6 ranges). The sensor connector offers easy connection and removal of wiring.
The PFMV5 is a small flow sensor with a rapid response time of less than 5ms. The PFMV5 series is mountable in a space-saving location since the straight piping length is not required. The PFMV3 voltage monitor for the PFMV5 series can cover a full range of sensors (6 ranges). The sensor connector offers easy connection and removal of wiring.
Quick response: valve response time: 5ms; vacuum response time: 28ms, Compact & lightweight: 0.101 lbs (46g) single unit weight, Air pressure and release pressure can be adjusted separately, Simple installation and removal, Available with pressure sensor or vacuum pressure switch, BRACKET, VACUUM EJECTOR