Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Type: Pneumatic, Bore Size: 100mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke 1: 10mm, +: None, Stroke 2: -, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch)
Magnet: -, Mounting: -, Type: -, Bore Size: -, Port Thread: -, Stroke 1: -, +: -, Stroke 2: -, Body Option: -, Auto Switch Groove: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Stroke Options: -
Magnet: None, Mounting: Standard, Through-hole, Bore Size: 40mm, Stroke 1: 10mm, +: None, Stroke 2: -, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Adjustable
Magnet: None, Mounting: Standard, Through-hole, Bore Size: 50mm, Stroke 1: 10mm, +: None, Stroke 2: -, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Adjustable
Magnet: None, Mounting: Standard, Through-hole, Bore Size: 63mm, Stroke 1: 10mm, +: None, Stroke 2: -, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Adjustable
Magnet: None, Mounting: Standard, Through-hole, Bore Size: 80mm, Stroke 1: 10mm, +: None, Stroke 2: -, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Adjustable
Magnet: Built-in Magnet, Mounting: Standard, Through-hole, Bore Size: 32mm, Stroke 1: 10mm, +: None, Stroke 2: -, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 80mm, Stroke 1: 10mm, +: None, Stroke 2: -, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Adjustable
Magnet: Built-in Magnet, Mounting: Standard, Through-hole, Bore Size: 100mm, Stroke 1: 10mm, +: None, Stroke 2: -, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options
Magnet: Built-in Magnet, Mounting: Standard, Through-hole, Bore Size: 40mm, Stroke 1: 10mm, +: None, Stroke 2: -, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
magnet V V V V V V V CJ2-A Air cushion 10, 16 V V 10-, 11Clean series*1 6 to 16 V V*9 v v 25ACopper (Cu) and Zinc (Zn)-free*5 10, 16 V v v v v v v XB6 Heat resistant cylinder (10 to 150C)*3, 4 v v v v v XB7 Cold resistant cylinder (40 to 70C)*3, 4 v v v v v 6 to 16 XB9 Low speed cylinder (10 to 50 mm/s)*4 XB13 Low speed cylinder (5 to 50 mm/s) 6 XC3 Special port position*2, 4 6 to 16 v XC8
125 to 300 Oversized rod cylinder 125 to 200 Heat-resistant cylinder (10 to 150 C) Cold-resistant cylinder 125 to 300 Low-speed cylinder (5 to 50 mm/s) Large-bore air-hydro cylinder 180 to 200 Special port location With heavy duty scraper Note) Heat-resistant cylinder (10 to 110 C) Stainless steel 125 to 300 Tie-rod, cushion valve, tie-rod nut and similar parts made of stainless steel XC7 XC8
Fluoro rubber for seal/Built-in hard plastic magnet, 20 to 100 only -X202 Same overall length dimension as Series CQ1, Except 16, 25 -X203 Same L dimension from rod cover as Series CQ1, 20, 32 only -X293 Same overall length as Series CQ1W, Except 16, 25 -X144 Change of port location, 12 to 25 only -X271 Fluoro rubber for seals -X525 Long stroke of adjustable extension stroke cylinder (-XC8