SMC Corporation of America
Elite Part Number Search
Search Results "CNA2L80TN-1300-D-XC35"

B A C D Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.

D-Y69A, D-Y69B, D-Y7PV D-Y7NWV, D-Y7PWV, D-Y7BWV ( ) MY1CW 25, 32, 40, 50, 63 B A Solid state switch D-Y59 , D-Y69 , D-Y7P(V) D-Y7NW(V), D-Y7PW(V), D-Y7BW(V) A B A B Reed switch D-Z73, D-Z76, D-Z80 D-Y7BAL 63 50 40 32 25 Mounting position 40 32 25 Mounting position 25 Mounting position 32 40 50 63 A 323.5 278.5 157.5 127.5 97.5 157.5 127.5 97.5 97.5 127.5 157.5 278.5 323.5 A A B 136.5 121.5

K J F H K J (D) F H 2 x P Port size 2 x P Port size Conduit terminal: T DIN terminal: D M N E (N) (M) E C C 25 32 31.5 (44) A A G1/2 L L G1/2 OUT IN OUT IN Applications B B (D) F H (D) F H K J K J 2 x P Port size Cable 6 to 12 2 x P Port size With bracket e a g d Bracket h b i (mm) Model A B C D E F H J K Port size P N.C. 1/4, 3/8 1/2 3/4 1/1 40 52 65 70 22 29.5 36 40.5 20 26 32.5 35 30

Positioning Time Guide Positioning time A: Acceleration time B: Constant velocity time C: Deceleration time D: Resting time (0.4sec.)

SMC Pneumatics, Inc. 8 Series ASIII1F-T Dimensions (mm) 1in=25.4mm L4 D3 Applicable tubing O.D. d L3 D1 L2 M1 M1 D2 L1 Metric sizes Inch sizes Model d D1 D2 D3 L1 L2 L3 L4 M1 M1 Model d D1 D2 D3 L1 L2 L3 L4 AS1001F-01T 1/8" 8.4 38 4.5 26 AS1001F-23T 3.2 8.4 38 4.5 26 12.7 12.7 AS1001F-03T 5/32" 9.3 39.2 5.2 26.6 AS1001F-04T 4 10 4.5 0.7 9.3 39.2 5.2 26.6 10 4.5 0.7 AS1001F-05T 3/16" AS1001F

See the table below Belt tension Size Belt N Part number Bolts LEF25 LE-D-6-2 19.6 pull LEF32 LE-D-6-3 49.0 LEF40 LE-D-6-4 98.1 4. "Pulley plate" is installed. Bolts Size Tightening torque (Nm) M3 0.6310% M4 1.510% M5 310% 8.Troubleshooting When a fault occurs during the operation, the corresponding alarm or warning is displayed.

(per unit) Applicable model A B C D HRSE012-AHRSE018-AHRSE024-A240 (335) 505 (540) HRW HRS-TK003 HECR HRSE012-A--T HRSE018-A--T HRSE024-A--T 240 (335) 555 (590) HEC HEB HED HEA IDH Anchor bolt (M8) D C (Prepared by user) Anti-quake bracket Material: Zinc steel plate Mounting view A B w Bypass Piping Set Note) To be mounted by user.

Auto Switches: Proper Mounting Positions and Mounting Heights for Stroke End Detection D-M9m D-M9mW D-M9mAL D-A9m D-M9mV D-M9mWV D-M9mAVL D-A9mV 32 to 100 20 Approx. U 25 B A Approx. U 20 32 to 100 D-F7m D-J79 D-F7mW D-J79W D-F79F D-A7m D-A80 D-A7mH D-A80H D-F7NTL D-F7BAL D-J79C D-A79W D-F7mWV D-J7mV D-F7BAVL D-A73C D-A80C CHQ CHKm CHN Approx. U CHM B A Approx.

JIS symbol Auto switch model D-A3, D-A44 D-G39, D-K39 D-A5, D-A6, D-A59W, D-F5, D-J5 D-F5W, D-J59W, D-F5NT, D-F5BA, D-F5F D-B5, D-B6 Bore size (mm) 40 50 63 80 100 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M BA-04 BA-05 BA-08 BA-10 BT-04 BT-06 BT-06 BT-08 BT-08 Standard Strokes Bore size (mm) Standard strokes (mm) 40 50 63 80 100 125 160 25 to 1000 25 to 1000 25 to 1000 25 to 1300 25 to 1500

in Area C in the case of 15. 25, 32, 40, 50, 63 (mm) Auto switch model A B C D D-Y5 D-Y7P D-Y7W D-A9 D-Y5 D-Y7P D-Y7W D-A9 D-Y5 D-Y7P D-Y7W D-A9 D-Y5 D-Y7P D-Y7W D-A9 D-M9 D-F9W D-Z7 D-Z80 D-M9 D-F9W D-Z7 D-Z80 D-M9 D-F9W D-Z7 D-Z80 D-M9 D-F9W D-Z7 D-Z80 Bore size (mm) 25 32 40 50 63 18 21.5 23.5 27.5 29.5 99 108.5 124.5 148.5 158.5 43 46.5 48.5 52.5 54.5 74 83.5 99.5 123.5 133.5 23 26.5

Auto Switch Proper Mounting Position Applicable Cylinders: MK2 Series D-M9 D-M9V D-M9W D-M9WV D-M9AL D-M9AVL D-A72/A7H D-A80H/A73C D-A80C/F7/F79F D-J79/F7V/J79C D-F7BA/F7W D-J79W/F7WV A Auto switch model D-A79W D-F7NTL D-A9 D-A9V D-A73 D-A80 D-P4DWL B B A A B A B A B B B A A Bore size 12 7 34 29 4 26 8 4 6.5 30 26 28.5 20 14 9 34.5 30 6 27 10 6 8.5 31 27 29.5 25 15.5 10.5 38 33.5 7.5

1, Metal joint q, w End plate (D) !2, Metal joint q, w, O-ring e, r, t, y, u End plate (D) !

For details, refer to page 443. 413 CHA Series How to Mount and Move the Auto Switch Solid state D-F59, D-F5P D-J59, D-F5BA D-F59W, D-F5PW, D-J59W D-F59F, D-F5NT Reed D-A53, D-A54, D-A56, D-A64, D-A67 D-A59W Solid state D-M9N(V), D-M9P(V), D-M9B(V) D-M9NW(V), D-M9PW(V), D-M9BW(V) D-M9NA(V), D-M9PA(V), D-M9BA(V) Auto switch mounting screw

JIS symbol Auto switch model D-A3, D-A44 D-G39, D-K39 D-A5, D-A6, D-A59W, D-F5, D-J5 D-F5W, D-J59W, D-F5NT, D-F5BA, D-F5F D-B5, D-B6 Bore size (mm) 40 50 63 80 100 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M BA-04 BA-05 BA-08 BA-10 BT-04 BT-06 BT-06 BT-08 BT-08 Standard Strokes Bore size (mm) Standard strokes (mm) 40 50 63 80 100 125 160 25 to 1000 25 to 1000 25 to 1000 25 to 1300 25 to 1500

Example) D-F9NL Main switch circuit Main switch circuit Output Black [White] () Blue [Black] D-F9P (+) Brown [Red] Auto Switch Dimensions (mm) 1in=25.4mm Output Black [White] D-F9N, D-F9P, D-F9B () Blue [Black] D-F9B (+) Brown [Red] L dimension (mm) Part No.

, D-Z76, D-Z80 Auto Switch Specifications Grommet D-Z7 (with indicator light) D-Z73 D-Z76 Auto switch part no.

Switches / Direct Mount Type D-Y7NW (V)/Y7PW (V)/D-Y7BW (V) Auto Switch Specifications D-Y7mW, D-Y7mWV (with indicator light) D-Y7NW D-Y7NWV D-Y7PW D-Y7PWV D-Y7BW D-Y7BWV Auto switch part no.