Mounting style B E Front nose mount Double end XB6-X6009* XB7-X6009* *XB6-X6009 contains XB6 seals and grease. XB7-X6009 contains standard XB7 seals and grease. Bore Size 075 088 106 125 150 200 3/4 7/8 1-1/16 1-1/4 1-1/2 Number of auto switches Nil S n L 2 pcs. 1 pc. n pcs.
DRail mounting Direct mounting 20D-A7H/A80H D-A73C/A80C D-F7BAL/F7BAVL D-F7/J79 D-F7V/J79C D-F7W/F79F D-F7WV D-J79W D-M9 D-M9V D-F9W D-F9WV D-F9BA D-A7/A80 D-A79W D-A9 D-A9V Bore size (mm) A 9 13 11 13.5 B 6 8.5 11.5 14.5 A 9.5 13.5 11.5 14 B 6.5 9 12 15 A 6.5 10.5 8.5 11 B 3.5 6 9 12 C 8 12 10 12.5 D 5 7.5 10.5 13.5 C 12 16 14 16.5 D 9 11.5 14.5 17.5 C 11 15 13 15.5 D 8 10.5 13.5 16.5 32
DRail mounting Direct mounting 20D-A7H/A80H D-A73C/A80C D-F7BAL/F7BAVL D-F7/J79 D-F7V/J79C D-F7W/F79F D-F7WV D-J79W D-M9 D-M9V D-F9W D-F9WV D-F9BA D-A7/A80 D-A79W D-A9 D-A9V Bore size (mm) D 8 10.5 13.5 16.5 C 11 15 13 15.5 D 9 11.5 14.5 17.5 C 12 16 14 16.5 D 5 7.5 10.5 13.5 C 8 12 10 12.5 B 3.5 6 9 12 A 6.5 10.5 8.5 11 B 6.5 9 12 15 A 9.5 13.5 11.5 14 B 6 8.5 11.5 14.5 A 9 13 11 13.5 32
150 0400 N 0200 R XC10 Stroke B Dual Operation Double Rod Auto Switch Mounting Bore Stroke A Cushions Both Ends N w/o Cushions H Head End R Rod End Dimensions PC P + A Stroke P + B Stroke Y Y 4-EE (NPTF) R K DD AA D Across Flats D Across Flats KK KK EA MM MM B B E/2 4-NT ND Deep SN + Stroke (A + B) Stroke B Stroke A G C A TN C G A E XT XT LD + Stroke (A + B) WF WF ZZ + Stroke (A + B) (in
Note) A B A B Specifications are the same as standard products with the exception of lead wire specifications. Lead wire: For D-F8, F9 type 2.7, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue) For other model nos. 3.4, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue) Dimensions are identical with D-F5 type, G5 type, J59 type, K59 type.
A B Hs Hs Hs Hs Hs Hs Hs Hs Hs Hs D-M9lV D-M9lWV D-M9lAV D-A9lV D-M9lV D-M9lWV D-M9lAV D-A9lV 17 B A A B D-H7l D-H7lW D-H7BA D-H7NF D-C7l D-C80 D-F7l D-F7lW D-J79 D-J79W D-F7BA D-F79F D-A7lH D-A80H 17 A B A B D-F7lV D-F7lWV D-F7BAV D-A7l D-A80 D-A79W D-H7C 17 A B A B D-C73C D-C80C D-J79C D-A73C D-A80C 17 Auto Switch Made to Order B A B A 102 C85/C75 Series Auto Switch Proper Mounting
D-Y7BAL D-A3 D-A44 D-G39 D-K39 D-A5 D-A6 D-A59W D-F5NTL D-P5DWL Bore size (mm) A B A B A B A B A B A B A B 32 1 3.5 1.5 4 0 0.5 9.5 12 4.5 7 2 4.5 0 0.5 CL 40 1 3.5 1.5 4 0 0.5 9.5 12 4.5 7 2 4.5 0 0.5 50 1.5 4 2 4.5 0 1 10 12.5 5 7.5 2.5 5 0 1 CL1 63 1.5 4 2 4.5 0 1 10 12.5 5 7.5 2.5 5 0 1 80 5.5 7 6 7.5 2.5 4 14 15.5 9 10.5 6.5 8 2.5 4 MLGC 100 5.5 7 6 7.5 2.5 4 14 15.5 9 10.5 6.5 8 2.5
Series MNB Cylinder with Lock Double Acting, Single Rod Proper Auto Switch Mounting Position D-F5W D-J59W D-F5 D-J5 D-F5BAL D-F59F D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W, D-Y7WV D-Y7BAL D-A3 D-A44 D-G39 D-K39 D-A5 D-A6 D-A59W D-F5NTL D-P5DWL Bore size (mm) A B A B A B A B A B A B A B 32 1 3.5 1.5 4 0 0.5 9.5 12 4.5 7 2 4.5 0 0.5 CL 40 1 3.5 1.5 4 0 0.5 9.5 12 4.5 7 2 4.5 0 0.5 50 1.5 4 2 4.5
Dimensions Meter-out type Meter-in type F E D B A C J G K H L B Model A MIN. MAX. MIN. MAX.
-XB7 Cold resistant (40C) Applicable Model Standard, Double acting, Single rod C(D)U XB7 Enter the applicable model number.
Outside Inside the controller 10k (a) 1k (a) IN0
A B For details about certified products conforming to international standards, visit us at www.smcworld.com.
For mounting tool adapter 3 x M3 x 0.5 depth 4 Hexagon socket head cap screw M3 x 14 (3 included) MHZ +0.022 0 depth 6 MHF 3 x 3 (A, B, C common view) MHL 6 x M2 x 0.4 thread depth 4 (A, B, C common view) MHR View D Open: 16, Closed: 10 Open: 22, Closed 14 MHK 15: MHR2-15-A310 1 2 Use MA3 0-AM3 for the tool adapter.
Be careful not to exchange the power cable (brown) with the output cable (black). 9-15-37 38 Solid State Switch Direct Mounting Style D-Y59 /D-Y69 /D-Y7P(V) A B A B For details about certified products conforming to international standards, visit us at www.smcworld.com.
0.2 0.1 0.2 C and b values are for controlled flow with the needle fully open and free flow with the needle fully closed.
WQ Edition B Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.
CM3 Auto Switch Proper Mounting Position (Centralized piping type, With end lock) CG1 (mm) Auto switch model D-H7l D-H7C D-H7lW D-H7BA D-H7NF CG3 D-C7l D-C80 D-C73C D-C80C D-G39A D-K39A D-A3lA D-A44A D-M9l(V) D-M9lW(V) D-M9lA(V) D-A9l(V) D-G5NT D-B5l D-B64 D-B59W JMB MB A B A B A B A B A B A B A B A B Bore size MB1 20 10.5 (8) 9.5 (7) 6.5 (4) 5.5 (3) 0.5 () 0 () 6 (4) 5 (3) 2.5 (0.5) 1.5
Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-A9(V) BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) D-M9A(V) Note 2) BMA3-020S (A set of b, c, d, e) BMA3-025S (A set of b, c, d, e) BMA3-032S (A set of b, c, d, e) BMA3-040S
The front cylinder B (rod end) must be equal to 5 to allow the full stroke.
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.