a v e Meial 0 3 3 0 3 9 N4ela 0 3 1 NC Va ve Base Mounted N O V a v e N C Valve lvleta 0 59 N O V a v e 3-port Base Mounted Valve conneclor with 300mrn lead wre M lpe plug teminalwithout lead wire Also Available 50700/5070 Manifolds Manifold 7mm width compacl 3 and 5 port valves with low power consumption of 0.35W (0.1W with power saving circuit) size (A port) 3-port Body Ported ffi ' Dc

5 V, 12 V IC circuit Grommet 12 V IC circuit Relay, PLC Yes Diagnostic indication (2-color display) 5 V, 12 V Grommet 12 V Water resistant (2-color display) 2-wire 3-wire (NPN equiv.)

D-A9(V)/M9(V)/M9W(V) Bore size (mm) Auto switch model 12 to 100 D-A9/A9V D-M9/M9V D-M9W/M9WV BMG2-012 BMG2-012 MGJ Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted. For detailed specifications, refer to pages 1719 to 1827.

Operating current of load (OFF condition) > Leakage current Auto switch operating range (mm) _ Time load applied (ms) V (mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches: Without auto switch

Silrc" lrcyrinder -NCM seies Stainless Steel Cylinders Stainless Steel Body for Low Breakway Friction Double Rod/Double End Mounting 6 Available Mounting Options Non-Rotating Option Auto Switch Capable Air Cylinder: Standard Type Series:NCM Series NCM How Toordcr NC DMrB075-02 00 C S J 851 xB6 T r I Lo**" Auto-Switch Capable I xB6 -High Temp. I XB7 -Low Temp.

Stainless Steel Body for Low Breakway Friction Double Roc/Double End Mounting 6 Available Mounting Options Non-Rotating Option Auto Switch Capable Air Cylinder: Standard Type Series:NCM Series NCM How Toordcr NC DMrB075-02 00 C S J 851 xB6 T r I Lo**" Auto-Switch Capable I xB6 -High Temp. I XB7 -Low Temp.

Data Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL Auto Switch Mounting Bracket Part No.

D-M9NW(V), D-M9PW(V), D-M9BW(V), D-M9NA(V)L, D-M9PA(V)L, D-M9BA(V)L Reed D-A90(V), D-A93(V), D-A96(V) Solid state D-M9N(V), D-M9P(V), D-M9B(V), D-M9NW(V), D-M9PW(V), D-M9BW(V), D-M9NA(V), D-M9PA(V), D-M9BA(V) Reed D-A90(V), D-A93(V), D-A96(V) How to Mount and Move the Auto Switch How to Mount and Move the Auto Switch Cylinder tube Auto switch mounting screw Watchmakers

(Up to 20 mA)/3 V or less (Up to 40 mA) 0.8 V or less Red LED illuminates when turned ON.

switch Grommet Diagnostic indication (2-color) Z76 Z73 Z80 F59 F5P J51 J59 F59W F5PW J59W F5BAL IC IC 3-wire 5 V Yes AC 100 100 V or less 12 V 5 V, 12 V Relay, PLC No PLC 24 V 2-wire Terminal conduit 12 V Yes 100 V, 200 V Relay, PLC DIN terminal 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC 24 V 100 V, 200 V 2-wire 12 V 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC Diagnostic indication (2