SMC Corporation of America
Elite Part Number Search
Search Results "CDUKW6-10D"

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 30 M26 x 1.5 21 83 4 x 30l Polished round 20 37 38 40 20 83 61 100 Y-10D +0.3 +0.1 MB Knuckle pin, cotter pin and flat washer are included.

Magnet: D (Built-in), Bore Size: 6 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 30 mm

Magnet: D (Built-in), Bore Size: 6 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 15 mm

Magnet: D (Built-in), Bore Size: 6 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 5 mm

Magnet: D (Built-in), Bore Size: 6 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 40 mm

Magnet: D (Built-in), Bore Size: 6 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 20 mm

Magnet: Built-in, Bore Size: 6 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 30 mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Bore Size: 6 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 15 mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Bore Size: 6 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 20 mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.18~0.7, Cushion: Rubber cushion

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.18~0.7, Cushion: Rubber cushion

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.18~0.7, Cushion: Rubber cushion

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.18~0.7, Cushion: Rubber cushion

Part Number Description: FINGER ASSY/MHQ2-10D S C   Product Line: A   Product Line Description: ACTUATOR   Family Code: 506   Family Description: MHQ/MHP GRIPPERS   Class Code: E1   Part Code: 2   Reference Code:  J   This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number

MH*-OMC0028 PRODUCT NAME Parallel Type Air Gripper MODEL / Series / Product Number MHL2-10D* MHL2-16D* MHL2-20D* MHL2-25D* MHL2-32D* MHL2-40D* Contents 1. Safety Instructions 2. Product Specifications 3. Operating method or operation 3-1. Operating environment 3-2. Air supply 3-3. Lubrication 3-4. Mounting 3-5. Finger attachment 3-6. Selection 3-7.

Double piston construction achieves compact design with strong gripping force. q r Mounting is possible from 4 directions. e w Model Bore size Gripping force (N) q w MHF2-8D MHZ2-10D 8 10 19 11 MHF2-12D MHZ2-20D 12 20 48 42 w e r MHF2-16D MHZ2-25D 16 25 90 65 MHF2-20D MHZ2-32D 20 32 141 158 12-3-3 4 Series MHF2 Model Selection Model Selection Selection Procedure Confirm gripping force Confirm

*Through-hole mounting is not used when mounting the auto switch for the 90-MHZJ2-10D. *When using the perpendicular auto switch for 10, the fitting and auto switch could mutually interfere.

An auto switch for detecting the location can be mounted. 10D MHZ2-16D 20D 10DN MHZ2-16DN 20DN Tool stand Added to the standard tool adapter The height for setting a tool can be adjusted. An auto switch for detecting a tool can be mounted. (Series MA3 only) (Series MA3 only) Rotary actuated type MHR2-10 15 Refer to AHC system Series MA. 12-12-17

Double piston construction achieves compact design with strong gripping force. q r Mounting is possible from 4 directions. e w Model Bore size Gripping force (N) q w MHF2-8D MHZ2-10D 8 10 19 11 MHF2-12D MHZ2-20D 12 20 48 42 w e r MHF2-16D MHZ2-25D 16 25 90 65 MHF2-20D MHZ2-32D 20 32 141 158 12-3-3 4 Series MHF2 Model Selection Model Selection Selection Procedure Confirm gripping force Confirm

Double piston construction achieves compact design with strong holding force. q r Mounting is possible from 4 directions. e w Model Bore size Holding force (N) q w MHF2-8D MHZ2-10D 8 10 19 11 MHF2-12D MHZ2-20D 12 20 48 42 w e r MHF2-16D MHZ2-25D 16 25 90 65 MHF2-20D MHZ2-32D 20 32 141 158 Features 2 Series MHF2 Model Selection Model Selection Selection procedure Confirm gripping force Confirm