170 4 x 11 32 32 Drain port Rc 1/4 120 180 312 460 Connected to VBA20A Connected to VBA22A Tank IN port Rc 3/8 Booster regulator IN port Rc 3/8 Booster regulator IN port Rc 3/8 EXH: Rc 3/8 EXH: Rc 3/8 (454) 442 (417) Tank OUT port Rc 1/2 (367) (367) OUT OUT 278 180 180 170 4 x 11 4 x 11 32 32 120 180 180 120 Drain port Rc 1/4 312 16 Series VBAT Dimensions: Standard Product (For Japanese

Station 2 52 43 Station 20 340 331 Station n L1 L2 3 68 59 4 84 75 5 100 91 6 116 107 7 132 123 8 148 139 9 164 155 10 180 171 11 196 187 12 212 203 13 228 219 14 244 235 15 260 251 16 276 267 17 292 283 18 308 299 19 324 315 41 Series SYJ5000 C6 N7 Type 42: Side Ported/SS5YJ5-42Stations -01, [ ]: AC C6 N7 Grommet (G) For 01 For (Built-in one-touch fitting) 65.2 [67.4] Approx. 300 (Lead

Cylinder series Bore size (mm) Technical Data 20 25 32 40 CDM2, CDBM2 CDLM2 BM3 020 BM3 025 BM3 032 BM3 040 Part No. of auto switch mounting band Cylinder series Bore size (mm) 20 25 32 40 50 63 80 100 125 140 160 180 200 CDA1, CDBA1, CDV3 BD1 -04M BD1 -05M BD1 -06M BD1 -08M BD1 -10M CDVS, CDLA, CE2, CNA CDL1 BS1 -125 BS1 -140 BS1 -160 CDS1 BS1 -180 BS1 -200 BD1 -01M BD1 -02M BD1 -02 BD1

Coordinate system in degrees 0 (-360) The coordinate is determined by referring to the position of 0 degree. + direction: 0 90 180 270 0 direction: 0 -90 -180 -270 -360 The positions of 270 degrees and -90 degrees are the same. The positions of 0 degree, 360 degrees and -360 degrees are the same.

[mm] D Model L B A n C E LEJB40S;;-200;-; 542 206 260 6 1 200 80 LEJB40S;;-300;-; 642 306 360 6 1 200 180 LEJB40S;;-400;-; 742 406 460 8 2 400 80 LEJB40S;;-500;-; 842 506 560 8 2 400 180 LEJB40S;;-600;-; 942 606 660 10 3 600 80 LEJB40S;;-700;-; 1042 706 760 10 3 600 180 LEJB40S;;-800;-; 1142 806 860 12 4 800 80 LEJB40S;;-900;-; 1242 906 960 12 4 800 180 LEJB40S;;-1000;-; 1342 1006 1060 14

CRQ2 L H Shock absorber for low energy Shock absorber for high energy MSQ Port location/Rotation MRQ Standard type 180 2 3 4 5 Rotation 180 90 90 180 D3: Standard type, 90 2: Standard type, 180 Symmetric type 90 Standard type Connecting port Connecting port Refer to the table to the right. 20Connecting port position 5: Symmetric type, 90 4: Symmetric type, 180 Symmetric type Connecting port

L H Low energy shock absorber High energy shock absorber Connecting port position and rotation Port location/Rotation Standard type 180 2 3 4 5 Rotation 180 90 90 180 3: Standard type, 90 2: Standard type, 180 Symmetric type 90 Standard type Connecting port Connecting port Refer to the table to the right.

-125, BS5-160 BS5-180, BS5-200 When D-F5BAL auto switch is shipped mounted on a cylinder, the above stainless steel screws are used.

Lx = 250 mm, Ly = 180 mm, Lz = 1000 mm 4.

If more precise repeatability of the rotation angle is required, use the product with an external stopper, with repeatability of 0.01 (180 and 90 with adjustment of 2) or by directly stopping the workpiece using an external object utilizing the pushing operation. When using angle adjustment, the initially set rotation angle may change.

VZ5140-5LZ1 pc. 90 100 180 190 270 280 90 100 180 190 270 280 Vane type CRQ2X MSQX S D Single vane Double vane MRQ Auto switch Nil Without auto switch (built-in magnet) For the applicable auto switch model, refer to the table below.

Refer to pages starting with 181 for mounting. 80 180 280 60 160 260 Dimensions inside ( ) are for a 100 mm stroke. Positioning Time Guide Positioning time Positioning time (sec.) A: Acceleration time B: Constant velocity time C: Deceleration time D: Resting time (0.4sec.)

Refer to pages starting with 181 for mounting. 80 180 280 60 160 260 Dimensions inside ( ) are for a 100 mm stroke. Positioning Time Guide Positioning time Positioning time (sec.) A: Acceleration time B: Constant velocity time C: Deceleration time D: Resting time (0.4sec.)

MHC Model MHT Note) Opening/Closing stroke (mm) Cylinder bore (mm) Rotating angle () Weight (g) MHY Action Model MHW 306 90 MRHQ10D 4 10 305 180 MRHQ 593 90 MRHQ16D 6 16 Misc. 591 180 Double acting 1055 90 MRHQ20D 10 20 D1052 180 1561 90 20MRHQ25D 14 25 1555 180 307 90 MRHQ10S MRHQ10C 4 10 306 180 MRHQ16S MRHQ16C 594 90 6 16 592 180 Single acting 1060 90 MRHQ20S MRHQ20C 10 20 1057 180 1566

Allowable end load F (N) MGGL 80Stroke 2 900st (Ball bushing type) Deflection Y (mm) 800st 700st 1 600st 500st 400st 200st 300st st: Stroke (mm) 100st 0 0 20 40 60 80 100 120 140 160 180 200 220 Allowable end load F (N) MGGL 100Stroke 2 1000st (Ball bushing type) 900st Deflection Y (mm) 800st 1 700st 600st 500st 400st st: Stroke (mm) 200st 300st 100st 0 0 20 40 60 80 100 120 140 160 180

) 4, 2 (A, B) 1, 5, 3 (P , EA, EB) 4/2 5/3 (A/B EA/EB) b C [dm3/(sbar)] Cv C [dm3/(sbar)] Cv b Grommet 125 (75) 170 (120) Single Double Closed center Exhaust center Pressure center 2 position 0.83 0.79 0.21 0.32 0.19 0.21 VZ340--01 Rc 1/8 Rc 1/8 0.86 1.1 [0.60] 0.72 0.80 0.71 0.99 [0.47] 0.28 0.26 0.29 [0.38] 0.34 0.24 [0.44] 0.38 0.18 0.18 0.24 [0.12] 0.20 0.26 [0.18] 0.18 3 position 180

1A 1.9 180 50 or less 0.95 (0.43) center % 2.0 Pressure NVFR3500 NYFR3510 If. 2.2 180 50 or less 0.95 (0.43) center % 2.3 i!

(mm) Bore size (mm) 63 80 100 Stroke range (mm) S AK AL AP AA AB AG AH AI AJ B I J K L M N O P T U V A 14 12 60 200 25 25 228 250 158 180 228 65 117 135 180 66 100 1/4 72 30 192 108 M12 x 1.75 depth 23 75, 100, 125 150, 200 250, 300 14 16 70 230 30 27 262 284 178 200 262 75 138 160 214 76 115 3/8 89 35 224 128 M12 x 1.75 depth 28 16 16 80 280 32 30 300 326 200 226 304 85 153 190 245 80 125

Stroke range (mm) Bore size (mm) AP AL AK AJ AI AH AG AB AA V U T S N M L K J I B A O P 63 60 12 14 180 158 250 228 25 25 108 192 30 72 100 66 180 135 117 65 228 200 Rc 1/4 M12 x 1.75 depth 23 75, 100, 125 150, 200, 250 300 80 70 16 14 200 178 284 262 27 30 128 224 35 89 115 76 214 160 138 75 262 230 Rc 3/8 M12 x 1.75 depth 28 100 80 16 16 226 200 326 300 30 32 143 262 40 110 125 80 245 190

MSUA1-90* P402070-3A MSUA1-180* P402070-3B MSUA3-90* P402090-3A MSUA3-180* P402090-3B MSUA7-90* P402060-3A MSUA7-180* P402060-3B MSUA20-90* P402080-3A MSUA20-180* P402080-3B *None that the rotation angle should not be changed even though the rotary unit has been changed. For maintenance, order units with a part number suitable for the model being used.