SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2WF12-15DMZ-M9PAVLS"

Magnet: Built-in, Rod Type: Standard, Mounting: Foot, Bore Size: 50mm, Stroke: 40mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: M9PAV--Solid State, Water Resist., 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 3m, Number: 1 pc.

Magnet: Built-in, Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 25mm, Stroke: 10mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: M9PAV--Solid State, Water Resist., 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 3m, Number: 1 pc.

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.08~1.0, Support bracket: Through-hole, Port thread type: Metric, Body Options: Rod end male thread,

Series: Standard w/ Magnet, Mounting: MX0, Basic, Bore Size: 2", Stroke: 6", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9PAV--Solid State, Water Resist., 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 3m, Number: 1 pc., X Option: -

Series: Standard w/ Magnet, Mounting: MX0, Basic, Bore Size: 2", Stroke: 16", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9PAV--Solid State, Water Resist., 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 3m, Number: 1 pc., X Option: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, ROTARY, CLAMP, ACTUATOR, MKA/MKB CLAMP CYLINDER, FE, 12MM MKA/MKB DBL ACT-AUTO-SW, .38580 lb

Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: M9PAV--Solid State, Water Resist., 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.), Environmental

Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rod End Male Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: M9PAV--Solid State, Water Resist., 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Environmental Options: Stainless

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: -, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: -, Valves: -, Operating Pressure(MPa): 0.08~1.0, Operating Pressure(MPa): -, Specification

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: -, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: -, Valves: -, Operating Pressure(MPa): 0.08~1.0, Operating Pressure(MPa): -, Specification

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder, Bore sizes *: 12, 16, 20, 25

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, FX, 12MM CQ2-Z DBL-ROD AUTO-SW, .40417 lb

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20,