Magnet: Built-in, Mounting: Double Clevis, Bore Size: 40mm, Port Thread Type: Rc, Stroke: 35mm, Body Option: C+M, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.1~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.1~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.1~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.1~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.1~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.1~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.1~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.1~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.1~1, Cushion: None, Specification: Built-in magnet, Support bracket
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
Note) The old D-F9BAL improved water resistance type auto switch (special order product equivalent in shape to “Z”: D-M9BAL(Z)-881) is still available.
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 40mm, Port Thread Type: Rc, Stroke: 100mm, Body Option: CM (C+M), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: Built-in, Mounting: Double Clevis, Bore Size: 40mm, Stroke: 75mm, Option: Rubber Bumper, Rod End Male Thread, Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.1~1, Cushion: None, Specification: Built-in magnet, Support bracket
Magnet: -, Mounting: -, Bore Size: -, Port Thread Type: -, Stroke: -, Body Option: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.1~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2-Z COMPACT CYLINDER, ME, 40MM CQ2-Z DBL-ACT AUTO-SW, .00000 lb