Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 32mm, Port Thread Type: F (Built-in One-touch Fittings), Stroke: 150mm, Body Option: M (Rod End Male Thread), Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 32mm, Port Thread Type: F (Built-in One-touch Fittings), Stroke: 250mm, Body Option: M (Rod End Male Thread), Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, IE, 25MM CQ2 DBL-ACT AUTO-SW, .74282 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, ME, 40MM CQ2 DBL-ACT AUTO-SW, .00000 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, LE, 32MM CQ2 DBL-ACT AUTO-SW, 1.04719 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, ME, 40MM CQ2 DBL-ACT AUTO-SW, 1.14823 lb
CK1 Load voltage Auto switch model Lead wire length (m) Pre-wired connector Applicable load DC AC Band mounting Rail mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line Perpendicular In-line Indicator light Type Special function Electrical entry Wiring (Output) C(L)K M9NV M9N M9NV M9N V V V v v IC circuit 3-wire (NPN) C(L)KU 5 V,12 V 3-wire (PNP) M9PV M9P M9PV M9P V V V v
Lead wire length (m) Indicator light Applicable model Load voltage Auto switch model Electrical entry Flexible (2) lead wire (-61) Pre-wire connector Applicable load Type Electrical entry Wiring (Output) Special function 5 (Z) 0.5 (Nil) 3 (L) 10 16 20 25 AC DC 6 Perpendicular In-line Standard M9NV M9N 3-wire (NPN) IC circuit IC circuit 5 V 12 V F8N Standard M9PV M9P Solid state switch 3
Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Band mounting Rail mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line Perpendicular In-line Indicator light Type Special function Electrical entry Wiring (Output) M9NV M9N M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V,12 V 3-wire (PNP) M9PV M9P M9PV M9P V V V v v Grommet Solid
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Band mounting Rail mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line Perpendicular In-line Indicator light Type Special function Electrical entry Wiring (Output) M9NV M9N M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V 3-wire (PNP) M9PV M9P M9PV M9P V V V v v Grommet Solid
(Example) CDQ2L40-200DCZ Long Stroke Load voltage Lead wire length (m) Auto switch model Indicator light 0.5 (Nil) 3 (L) 5 (Z) None (N) Applicable load Pre-wired connector 1 (M) Type Special function Wiring (Output) Electrical entry DC AC Perpendicular In-line M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV M9N M9P M9B M9NW M9PW M9BW M9NA 5 V, 12 V 12 V 5 V, 12 V 12 V 5 V, 12 V 12 V 3-wire (NPN) 3
For 10, 16, 20 Lead wire length (m) Auto switch model Pre-wire connector Applicable load Perpendicular In-line Load voltage Indicator light Electrical entry Special function Wiring (Output) Type 0.5 (Nil) 3 (L) 5 (Z) DC AC A96 A93 M9N M9P M9B F9NW F9PW F9BW A96V A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 3-wire (NPN equivalent) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP)