SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2WB40TN-200-D"

# # ( ) Hw Ht Hv D-A7, D-A80 D-F7, D-J79, D-J79W, D-F7W, D-F79F, D-F7BAL, D-F7NTL D-A7H, D-A80H D-A73C, D-A80C D-F7V, D-F7WV, D-F7BAV D-J79C !# $% ! !% ! # " Slide Unit: Built-in Shock Absorber Slide Bearing Type Series CXWM 16 Basic Type: CXWM16Stroke/50 to 200 Max.

Auto Switch Proper Mounting Height (Standard type) [mm] Auto switch model D-F5l D-J59 D-F59F D-F5lW D-J59W D-F5BA D-F5NT D-Y59l D-Y7P D-Y7lW D-Y7BA D-Z7l D-Z80 D-M9l D-M9lW D-M9lA D-A9l D-A9lV D-M9lV D-M9lWV D-M9lAV D-A5l D-A6l D-A59W D-Y69l D-Y7PV D-Y7lWV D-P3DWA D-P4DW D-G39 D-K39 D-A3l D-A44 Bore size Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 32 24.5 23 27.5 23

Over 25 st 50 st or less Over 50 st 200 st or less Over Over 25 st 50 st or less Over 50 st 200 st or less 158.5 Over 200 st 8 200 st 80 100 80 100 104.5 126.5 104.5 191.5 25 32 62 95 119.5 145.5 178.5 201.5 30 3.5 29.5 62.5 85.5 20 Series MGP Auto Switch Mounting 1 Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto switch D-A9 D-A9V D-M9 D-M9V D-M9W

Size M4 x 0.7 x 8 L Q'ty 1 BTBT-03, BT-04, BT-05 BT-06, BT-08, BT-12 D-A5, A6 D-F5, J5 D-Z7, Z8 D-Y5, Y6, Y7 BA4-040, BA4-063, BA4-080 BMB4-032, BMB4-050 2 Set screw M4 x 0.7 x 6 L 2 BMB5-032 BA7-040, BA7-063, BA7-080 D-A9 D-M9 BBA1 D-A5, A6 D-F5, J5 BT-16, BT-18A, BT-20 BS4-125, BS4-160 BS4-180, BS4-200 BS5-125, BS5-160 BS5-180, BS5-200 D-Z7, Z8 D-Y5, Y6, Y7 3 Set screw M4 x 0.7 x 8 L 2

200 212.5 225 225 237.5 237.5 250 L5 21 18 21 24 20.5 23.5 20.5 23.5 29 Plug-in Connector Connecting Base JSY1000/3000/5000 Series Type 10/Side Ported (Applicable to 6 fittings) EX120 EX260 EX250 EX600 EX245 Chart Valve Lead Wire D-sub Flat Ribbon Dimensions: JSY1000 Series D-sub Connector (IP20/Compact Type) JJ5SY1-10FC C6(D) 1 2 U D B Stations Connector Connecting Base U side D side Light

Bore Model No. 150 (1.5) 200 (2) 250 (2.5) 325 (3/25) 400 (4) D-A5, D-F5 D-A6, D-J5 NBT-150 NBT-200 NBT-200 NBT-325 NBT-325 M8-3pin M8-4pin M12-4pin Connector Style 1 2 1 4 Pin arrangement 2 1 3 4 4 3 3 JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 300m/s2 Applicable standards Impact resistant IP degress of protection Insulation resistance Withstand voltage IP-67 (IEC529 standard) 100Mor

Note 4) D-Z7 and D-Y types cannot be mounted. 25 to 63 (mm) Auto switch model D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W A B C D D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-A9 D-M9 D-M9W D-A9 D-M9 D-M9W D-M9 D-M9W D-A9 D-M9 D-M9W D-A9 Bore size (mm) 25 32 40 50 63 19 23 18 98 94 99 42 38 43 75 79 74 22.5 26.5 21.5 107.5 103.5 108.5 45.5 41.5 46.5 84.5 88.5 83.5

No. 1 1 Size M4 x 0.7 x 8L CHN BT-mm BT-03, BT-04, BT-05 BT-06, BT-08, BT-12 D-A5, A6 D-F5, J5 CHM D-Z7, Z8 D-Y5, Y6, Y7 BA4-040, BA4-063, BA4-080 BMB4-032, BMB4-050 2 Set screw M4 x 0.7 x 6L 2 CHSm D-A9 D-M9 BMB5-032 BA7-040, BA7-063, BA7-080 BBA1 CH2m D-A5, A6 D-F5, J5 BT-16, BT-18A, BT-20 CHA D-Z7, Z8 D-Y5, Y6, Y7 BS4-125, BS4-160 BS4-180, BS4-200 BS5-125, BS5-160 BS5-180, BS5-200 When

There may be large variations depending on the surrounding environment (variations on the order of 30%). 12 Solid State Switches/Direct Mount Type D-Y59 /D-Y69 /D-Y7P(V) A B A B Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch part no.

There may be large variations depending on the surrounding environment (variations on the order of 30%). 12 Solid State Switches/Direct Mount Type D-Y59 /D-Y69 /D-Y7P(V) A B A B Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch part no.

CG1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Auto Switch Mounting Height (mm) MB D-Z7/Z-80 D-Y59 D-Y7P D-Y7W D-F5, D-J5 D-F59F D-F5W, D-J59W D-F5BAL, D-F5NTL D-A5 D-A6 D-A59W D-A3 D-G39 D-K39 D-Y69 D-Y7PV D-Y7WV Bore size D-Y7BAL D-A44 D-P5DWL MB1 (mm) Ht Hs

Auto Switch Mounting Height (Except low friction, air-hydro cylinders) (mm) D-B5 D-B64 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G5BAL D-G59F Auto switch model D-A9 D-M9 D-M9W D-M9AL D-F5 D-J59 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-Z7 D-Z80 D-Y59 D-Y7P D-Y7BAL D-Y7W D-Y69 D-Y7PV D-Y7WV D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W D-A3C D-G39C D-K39C D-A44C D-A9V D-M9V D-M9WV D-M9AVL D-P4DWL Bore

(When using 10-SS5Y-60-D, block disk is assembled on D side.) sheet. (When using 10-SS5Y-60-D, block disk is assembled on D side.)

M Special specifications Mixed M D D side In the case of mixed specifications (M), indicate separately on the manifold specification sheet.

Mounting Position and Mounting Height [First angle projection] (Band mounting type) (Rail Mounting type) D-C7 D-C80 D-A7 D-A80 ( ): In case of D-A72 D-A7H D-A80H D-C73C D-C80C D-H7 D-H7W D-H7BAL D-H7NF D-A73C D-A80C D-H7C D-A79W D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F Auto Switch Mounting Position (mm) 1 to 50 st 51 to 100 st 101 to 150 st 151 to 200 st 151 to 200 st Bore Single acting/Spring

Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com D-H7 D-H7W D-H7BAL D-H7NF D-A73C D-A80C D-H7C D-A79W D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F Auto Switch Mounting Position (mm) 1 to 50 st 51 to 100 st 101 to 150 st 151 to 200 st 151 to 200 st Bore Single acting/Spring extended Auto switch model B

-m LECSS2-m L11 L21 For single phase 200 VAC For three phase 200 VAC L1 CNP1 NFB MC CNP3 L1 CNP1 NFB MC CNP3 Single phase 200 to 230 VAC Three phase 200 to 230 VAC L2 L2 U U U Motor V U Motor V L3 L3 V V W M N W M N() W W P1 P1 PE PE P2 P2 CNP2 CNP2 P P(+) Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power

120 201 to 300st 200 200 301 to 400st 300 300 20 to 39st 29 29 40 to 124st 39 39 125 to 200st 77 77 201 to 300st 117 117 301 to 400st 167 167 20 25 20 to 400 WA WB Bore size (mm) Standard stroke (mm) 25 to 49st 24 24 24 28 28 48 50 to 124st 48 48 48 52 52 72 125 to 200st 124 124 124 128 128 148 201 to 300st 200 200 200 200 200 220 301 to 400st 300 300 300 300 300 320 25 to 49st 33 34 36 38

Up to 200 Up to 300 Up to 300 Up to 300 1-7-38 Direct Mount: Double Acting Series CG1R Auto Switch Mounting Position and Mounting Height CJ1 CJP CJ2 CM2 C85 C76 CG1 MB MB1 CP95 C95 C92 CA1 CS1 Auto Switch Mounting Position Mounting Height (mm) Auto switch model D-C7, C8 D-C73C, C80C D-C7, C8 D-H7 D-H7W D-H7F D-H7BAL D-B5, B6 D-B59W D-G5, K5 D-G5W D-K59W D-G5NTL D-G59F D-G5BAL D-B5, B6 D-G5W