Output type Load voltage Lights when ON 2 color indicator Relay, PLC D-F9N D-F9NV NPN type 8mA or less 0.4V or less 28VDC or less 10A or less at 24VDC D-F9NW D-F9NWV D-F9P D-F9PV 12mA or less 24VDC (10 to 28VDC) 50mA or less Lights when ON 2 color indicator 10mA or less PNP type 1.5V or less D-F9PW D-F9PWV Lights when ON 4.5V or less D-F9B D-F9BV 1mA or less at 24VDC 24VDC (10 to 28VDC) 24VDC
Output type Load voltage Lights when ON 2 color indicator Relay, PLC D-F9N D-F9NV NPN type 8mA or less 0.4V or less 28VDC or less 10A or less at 24VDC D-F9NW D-F9NWV D-F9P D-F9PV 12mA or less 24VDC (10 to 28VDC) 50mA or less Lights when ON 2 color indicator 10mA or less PNP type 1.5V or less D-F9PW D-F9PWV Lights when ON 4.5V or less D-F9B D-F9BV 1mA or less at 24VDC 24VDC (10 to 28VDC) 24VDC
Auto switches / Proper mounting position for stroke end detection Electrical entry direction: Inward Electrical entry direction: Outward B D C A (mm) D-Z73 D-Y59A,D-Y59B A B C D Bore size D 0.5 4 0.5 3 5 5 C 16.5 23 34 46 46.5 56 6 20.5 27 38 50 50.5 60 -1 2.5 -1 1.5 3.5 3.5 32 15 21.5 32.5 44.5 45 54.5 4.5 8 4.5 7 8.5 9 10 15 20 25 Note 1) The above mentioned values are indicated as a guide
For D-A93, only outward electrical entry (D dimension) is available. Dimensions in parentheses apply to 12-CXSJ6. CXSJ10 / CXSJ10 11122122Note 2) D B Note 3) (mm) D-M9 34 (35.5) 3.5 (2) 24 (25.5) 6.5 (8) D-A93 30 (31.5) 25.5 (27) 5 (6.5) Symbol A B C D Note 1) The above mentioned values are indicated as a guide for auto switch mounting positions for stroke end detection.
, D-F9WV D-F9P B, D-F9W D-A9V D-F9N D-F9V Number of auto switches 2 pcs. 15 Note) 20 Note) 10 10 5 10 Note) 15 Note) 20 Note) 5 5 1 pc.
Port thread type (for 32) Nil TN TF Rc NPT G Action D Double acting M5 for 15 to 25.
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Bellows/Cushion: Cushion Both Sides
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 600mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Magnet: Built-in Magnet, Mounting: Center Trunnion, Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Center Trunnion, Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Center Trunnion, Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Center Trunnion, Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: J59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Center Trunnion, Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: J59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -, Made to Order: -