SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2F100TN-75-D-XC35"

Dimensions and the most sensitive positions are same as the conventional types. s D-M9N (s-vvire, NPN output) M-F9N -^ D-W9P *8 c-"*t"*r D-FQB 17 D-MgN D-MgP Nwtypes D-MgB nil;'Y,r dCl D-MgP (3-wke, PNP output) D-MgB (2-wire) Range of load 5 t o wire:4 timesrn" New types tr{lur$ D-FgB 5 to 40mA D.M9B 2.5 to 40mn lead wire is available as siandard. 41ime6 more bl f e x b e Indicator Light:

MP2 Double detatchable head side clevis style (D) XD + Stroke A UB P + Stroke 2-EE MR MAX KK MM B CD (PIN) TH LR CB E WF LF + Stroke F Bore Size (in) MM KK A B CB CD E EE F LF+ LR MR P+ TH UB WF XD+ 500 (5") 1.000 3/4-16 1.13 1.500 1.280 .750 5.50 1/2 NPT .63 4.50 .94 .95 2.88 2.75 2.500 1.38 7.75 600 (6") 1.375 1-14 1.63 2.000 1.530 1.000 6.50 3/4 NPT .75 5.00 1.31 1.32 3.13 3.25 3.000 1.63

D-A9/M9/M9W auto switches are shipped together (not assembled). (However, auto switch mounting brackets are assembled when being shipped.) Solid state auto switches marked with are produced upon receipt of order. D-A9V/M9V/M9WV and D-M9A(V)L cannot be mounted. Do not indicate suffix N for no lead wire on D-A3A/A44A/G39A/K39A models.

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 75mm, Bellows/Cushion: Cushion Both Sides

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 350mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 100mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 250mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 125mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 300mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 50mm, Bellows/Cushion: J (Nylon Tarpaulin+Cushion Both Sides), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 50mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 200mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 700mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No