Q: 8 Y K P K P ZPT20F10-0-A14 ZPT40F10-0-A14 18.5 39 51.5 118 136.5 13 140 5 12.5 20 22 40 43 13 15.5 36 48.5 50 115 13 133.5 13 137 12.5 52.5 50 ZPT25F10-0-A14 ZPT50F10-0-A14 19.5 40 119 137.5 141 6 13.5 25 28 50 53 ZPT32F10-0-A14 16 36.5 49 115.5 134 135.5 13 32 35 Additional Dimensions by Stroke (mm) Additional Dimensions by Stroke (mm) K P Q: 6 Q: 8 K P 5.1 K P Q: 6 Q: 8 K P 5.1 Stroke
VQ1000 Series P.1.10-124 P.1.10-128 P.1.10-132 Plug-in Plug lead VQ2000 Series P.1.10-124 P.1.10-128 P.1.10-132 VQ0 Series P.1.10-170 P.1.10-174 VQ1000 Series P.1.10-170 P.1.10-174 P.742 1.10-114 Manifold Variations T L C S Port size SUP EXH port Cylinder port kit kit kit Lead wire Direct electrical entry style Serial transmission unit Terminal box (Terminal block) SY P, R A, B Enables single-wire
Type 90-VG342 P.9 3 Port Solenoid Valve Direct Operated Poppet Type 90-VT317 P.10 90-VHK Finger Valve P.11 Actuators Air Filters/Pressure Control Equipment Air Cylinder: Standard Type Double Acting, Single Rod 90-CDJ2 P.12 90-AF30 to 90-AF60 90-AFM30/90-AFM40 90-AFD30/90-AFD40 90-AR30/90-AR40 90-AR25K to 90-AR60K 90-AW30K to 90-AW60K 90-IR1000/2000/3000 90-ITV2000 P.48 P.49 P.49 P.50 P.50
Model Port size A B C D M N P R B B E F G H J K L AL 58 90 117 117 154 164 195 200 205 M5 X 0.8 11 17 25 35 37.5 40.5 48 48 48 70 103.5 140 150 184.5 189.5 268 282 282 26 56.8 60.8 60.8 65.5 69.5 75.5 75.5 78 25 40 53 53 70 70 90 95 95 29 45 58.5 58.5 77 82 97.5 102.5 102.5 25 30 41 41 50 50 70 70 70 4.5 5.5 7 7 9 9 12 12 12 20 24 35 35 40 40 50 50 50 17.5 22 34.2 34.2 42.2 46.2 55.2 55.2
= 2, 4, 6, 8 110 + 50 (n 2) n = 2, 4, 6, 8 Same side 1 10 90 100 110 20 90 100 110 75 90 100 110 Different sides With 2 Same side (n 2) 2 90 + 50 (n 4) 2 n = 4, 8, 12, 16 100 + 50 (n 4) 2 n = 4, 8, 12, 16 100 + 50 (n 4) 2 n = 4, 8, 12, 16 20 + 50 n = 2, 4, 6, 8 Different sides D-B59W With n 75 + 50(n 2) n = 2, 3, 4 90 + 50(n 2) n = 2, 4, 6, 8 100 + 50 (n 2) n = 2, 4, 6, 8 110 + 50
N.O. + P. 4-4-37 SYJ300 Push-turn locking slotted type Note) For AC For AC 0.36 2 3 (A R) M5 x 0.8 With light/surge voltage suppressor 100 VAC Hz 110 VAC Hz 200 VAC Hz 220 VAC Hz 50 60 50 60 50 60 50 60 P. 4-4-4 SYJ500 Push-turn locking lever type DIN terminal 1.2 2 3 (A R) 1/8 (SYJ500, 700 only) P. 4-4-18 SYJ700 M8 connector 2.7 2 3 (A R) 1/8, 1/4 P. 4-4-37 Note) All AC voltage
m P 0.1 x m + m P D 1.6 x D 5.0 x D 5.0 x m m mv P Pv m > mv P > Pv Determination of allowable load mass & pressure Inclined operation (Refer to page 1236
Symbol Specifications DC AC (0.35 W) p Nil Standard p p (0.9 W) B Note) High speed response type High pressure type (Metal seal type only) (0.9 W) p K Note) Note) Option Electrical entry Light/surge voltage suppressor Coil voltage Electrical entry Symbol 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Y YO YZ YS Note) DIN terminal DIN
VQZ2000) VVQZ3000-R-5-02 (for VQZ3000) P.959 P.959 P.959 P.959 Port plug VVQZ1000-CP (for VQZ1000) VVQZ2000-CP (for VQZ2000) VVQZ3000-CP (for VQZ3000) Name plate [-N] (Applicable to VQZ2000/3000) VVQZ2000-N5(for VQZ2000) VVQZ3000-N5(for VQZ3000) DIN rail AXT100-DRBlanking plug KQ2P-23 KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 Stations Stations + + + P.959 P.960 P.960 P.960 Silencer (for EXH port) Perfect
MXS 75 to 124 stroke 50 to 74 stroke MXQ 100 100 200 63 P=0.5MPa P=0.5MPa MXF 80 50 40 50 100 MXW 40 Load weight m (kg) Load weight m (kg) 30 40 50 32 MXP 20 30 MG 10 20 MGP 5 4 3 10 MGQ 5 10 100 200 20 30 40 50 1 100 10 200 20 30 40 50 2 3 4 5 MGG Eccentric distance l (mm) Eccentric distance l (mm) MGC Over 75 stroke Over 125 stroke MGF 100 100 63 200 P=0.5MPa P=0.5MPa CY1 80 100 50 Load
(R1)5 1 (P) 3(R2) Coil voltage CE-Compliant SQ 3-position exhaust center 1 2 Note) 3 4 Note) 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC 2(B) (A)4 4 VFS (R1)5 1 (P) 3(R2) 3-position pressure center VFR 2(B) (A)4 5 (R1)5 1 (P) 3(R2) VQ7 Note) 200 and 220 VAC: F/L kit only Note) For sub-plate single unit type, refer to page 417.
U B E Applicable Tube OD P Q R S 4 4 23.3 15.8 10.4 H O W T O O R D E R ZPR P A D H O R I Z O N TA L T Y P E 6 6 24.3 16.8 12.8 8 8 26.2 18.7 15.2 W I T H B U F F E R ZPR D I M E N S I O N S PA D D I A M E T E R S 40, 50 P A D D I A M E T E R M O U N T I N G T H R E A D 16 16 20 20 25 25 32 32 40 40 50 50 02 2 04 4 06 6 08 8 10 10 13 13 Symbol Thread Dia 2~8 10~16 40~50 20~32 A8 M8X1 Male
P Signals and terminal status can be monitored. P Parameters can be set.
/60 Hz 50/60 Hz 3-position (Closed center) Double Single Metal seal (F/L kit only) VQ100 0.72 0.72 Base Mounted Series VQ1000 Rubber seal 1.0 0.65 Plug-in VQ101 P. 15 P. 7 Metal seal (F/L kit only) Series VQ2000 2.6 2.0 VQ200 Rubber seal 3.2 2.2 VQ201 P. 15 P. 11 1 Series VQ1000 Series VQ2000 A variety of common wiring methods are standardized.
0.3 x Wcos + Wsin D 5.0 x P 0.3 x W + W D 5.0 x P 20Data W W > Wv P > Pv Determination of allowable load weight & pressure Inclined operation (For vertical operation, refer to page 8-15-50.)
A AL B1 C CD CX CZ D E F H H1 I J K KA L MM NA Standard Long stroke GA GB P GA GB P 80 Up to 300 301 to 1500 20 16 (20) 3/8 17.5 16 (17.5) 3/8 40 37 32 50 18 28 56 25 40 3 71 13 89 M10 x 1.5 10 22 35 M22 x 1.5 86 100 Up to 300 301 to 1500 20 16 (20) 1/2 17.5 16 (17.5) 1/2 40 37 41 60 22 32 64 30 50 3 71 16 110 M12 x 1.75 10 26 43 M26 x 1.5 106 (mm) (mm) With Air Cushion With Rod Boot (mm
P.12 to P.15 3 ( Size ) 16, 25, 40 XLFV (With solenoid valve) High speed operation O-ring Seal 2 x 105 to 10-5 10-10 10-10 High volume operation 2 ( Size ) 50, 63, 80 XLG Double acting P.16 to P.19 XLGV (With solenoid valve) XLD Standard Reduces particulates Single acting (N.C.)
PI Control Level 1 P control 4 Switches the speed control from PI control to P control.
P. 192 Refrigerator P. 192 Relay P. 198 Relief valve P. 195 RS232C P. 198 RS485 P. 198 RTD (Resistance Temperature Detector) P. 196 S Sealing mechanism P. 194 SEMI F47 P. 199 SEMI S2 P. 199 SEMI S8 P. 199 Signal input/output, I/O P. 199 Solenoid valve P. 195 Solid state relay (SSR) P. 198 Specific heat/Specific heat capacity P. 195 Specific resistance P. 195 Specified CFC P. 192 SV P. 196
P.12 to P.15 3 ( Size ) 16, 25, 40 XLFV (With solenoid valve) High speed operation O-ring Seal 2 x 105 to 10-5 10-10 10-10 High volume operation 2 ( Size ) 50, 63, 80 XLG Double acting P.16 to P.19 XLGV (With solenoid valve) XLD Standard Reduces particulates Single acting (N.C.)