SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2F63-900-D"

D-G5P D-K59 D-5NTL D-H7A1 D-H7A2 D-H7B D-H7C D-G59W D-G5PW D-K59W D-G59F D-G79 D-H7PW D-H7BAL D-H7LF D-H7NF D-G5BAL D-H7PW D-H7BW 24VDC 110VAC 220VAC 24VDC 24VDC 110VAC 220VAC 24VDC 110VAC Yes/2 Wire D-B54 Yes/2 Wire D-B53 No/2 Wire D-B64 D-B73 D-C73 D-C73C D-B76 D-C76 D-B80 D-C80 D-C80C Yes/2 Wire Yes/2 Wire 20mA 4~8VDC 50mA 40mA 20mA 24V 48V 110V No/2 Wire ACCESSORIES SWITCH BANDS FOR

Construction/Parts/Dimensions AN500 to 900 End plate (Carbon steel) Tension bolt (Carbon steel) (mm) Dimensions Sound absorbing material (Resin sintered body) Model Port size R, NPT AN500-06 AN600-10 AN700-12 AN800-14 AN900-20 A B D A Cover (Carbon steel) 3/4 107 46 36 Body (Aluminum alloy) 1 127 50 41 1 1/4 186 74 50 Hexagonal flats D 1 1/2 217 74 55 2 256 86 65 Port size B 4 Series AN Specific

D-M9WV D-M9AL D-M9AVL 16, 20 U 25 B A D-A7 D-A80 D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F79F D-F7NTL D-F7BAL D-A73C D-A80C D-J79C D-A79W D-F7WV D-F7V D-F7BAVL 16, 20 U A B 32 to 50 U A B 32 to 50 D-A9 D-M9 D-M9W D-M9AL D-A9V D-M9V D-M9WV D-M9AVL U B A 1384 Stopper Cylinder / Fixed Mounting Height Series RSQ Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height

Auto Switch Mounting Height [mm] D-F5m D-F5mW D-J59 D-J59W D-F59F D-F5BAL D-F5NTL Auto switch model D-Y59m D-Y7P D-Y7mW D-Y7BAL D-Z7m D-Z80 D-M9mV D-M9mWV D-M9mAV D-A9mV D-M9m D-M9mW D-M9mA D-A9m D-Y69m D-Y7PV D-Y7mWV D-A5m D-A6m D-A59W D-G39 D-K39 D-A3m D-A44 D-P4DW Bore size Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 32 24.5 23 30.5 23 32.5 25 35 24.5 25.5 23 26.5 23 67 27.5

CG1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Auto Switch Mounting Height (mm) MB D-Z7/Z-80 D-Y59 D-Y7P D-Y7W D-F5, D-J5 D-F59F D-F5W, D-J59W D-F5BAL, D-F5NTL D-A5 D-A6 D-A59W D-A3 D-G39 D-K39 D-Y69 D-Y7PV D-Y7WV Bore size D-Y7BAL D-A44 D-P5DWL MB1 (mm) Ht Hs

RHC RZQ D-X Individual -X 961 Series REAS Auto Switch Proper Mounting Position (Detection at Stroke End) B A (mm) A dimension B dimension Auto switch model D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/F7WV D-F7BA D-F79F D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/FWV D-F7BA D-F79F D-F7NTL D-A73/A80 D-F7NTL D-A73/A80 Bore size (mm) 10 35 35.5 45 44.5 40.5

15 Auto switch model Bore size (mm) D-A9 A dimension D-M9 B dimension C dimension D dimension D-A9 D-M9 D-A9 D-M9 D-A9 D-M9 21.5 76.5 72.5 56.5 60.5 17.5 15 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 A dimension D-Y5 D-Y6 D-Y7 B dimension C dimension D dimension Auto switch model D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8

case of 15. 25, 32 A dimension D-Y5 D-Y6 D-Y7 B dimension C dimension D dimension Auto switch model D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 Bore size (mm) 25 22 103 103 47 47 78 78 22 32 30.5 117.5 117.5 55.5 55.5 92.5 92.5 30.5 Operating Range Bore size (mm) Auto switch model 32 25 15 D-A9 8 D-M9 3 D-Z7/Z8 9 9 D-Y5/Y6/Y7 6 7 Since this

Cylinder Speed Chart Bore size Series CS1/CS2 Pressure 0.5 MPa, Load factor 50% Cylinder stroke 300 mm Average velocity (mm/s) System 125 140 160 180 200 250 300 1000 Vertically upward movement Horizontal movement 900 800 700 600 500 400 300 200 100 0 A 800 900 1000 700 600 500 400 300 200 100 0 B 900 1000 800 700 600 500 400 300 200 100 0 C 800 900 1000 700 600 500 400 300 200 100 0 D 800

Auto Switch Mounting Height (mm) D-Z7/Z80 D-Y5/Y6 D-Y7P D-Y7PV D-Y7W D-Y7WV D-Y7BAL Hs D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL Hs Auto switch model D-A9 D-A9V D-M9 D-M9W D-M9AL D-M9V D-M9WV D-M9AVL D-A3 D-G39 D-K39 D-A5 D-A6 D-A59W D-A44 Bore size (mm) Ht Ht Ht Ht Ht Hs Hs Hs Hs Hs D125 140 160 180 200 69 69.5 71.5 69.5 69 69.5 116 126 75.5 69.5 74.5 70 -X 76 76 77.5 76 76 76 124 134

Hs 33 Proper auto switch mounting positions Auto switch mounting height (mm) (mm) Auto switch models D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W Auto switch models D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F5F D-F5NTL D-A5/A6 D-A3 D-A44 D-G39 D-K39 D-F5W D-J59W D-F5BAL D-F5 D-J5 D-A59W D-F5NTL D-F5F Bore size (mm) Bore size (mm) A B A B A B B A B Hs Hs Ht Hs Ht Hs A 125 125 0 0 2 2 4.5 4.5 8.5 8.5 9.5

(2.5 to 40 mA). # The optimum operating range can be D-M9NAV D-M9NA D-M9BA D-M9BAV D-M9PAV D-M9PA Auto switch model In-line Perpendicular In-line Perpendicular In-line Perpendicular Electrical entry determined by the color of the light.

model D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-A5 D-A6 D-A3 D-A44 D-G39 D-K39 D-F5W D-J59W D-F5BAL D-F5 D-J5 D-F59F D-A59W D-F5NTL Bore size (mm) Bore size (mm) A B A B A B A B Hs Hs Ht Hs Hs Ht 125 125 2 75.5 69.5 74.5 70 116 126 4.5 4.5 9.5 9.5 0 0 2 140 140 2 81 76.5 80 76.5 124 134 4.5 4.5 9.5 9.5 0 0 2 160 160 2 89 87.5 88 87.5 134.5 144.5 4.5 4.5 9.5 9.5 0 0 2 180 180 7.5 97.0

See the table below Belt tension Size Belt N Part number Bolts LEF25 LE-D-6-2 19.6 pull LEF32 LE-D-6-3 49.0 LEF40 LE-D-6-4 98.1 4. "Pulley plate" is installed. Bolts Size Tightening torque (Nm) M3 0.6310% M4 1.510% M5 310% 8.Troubleshooting When a fault occurs during the operation, the corresponding alarm or warning is displayed.

Hs Proper auto switch mounting positions Auto switch mounting height (mm) (mm) Auto switch models D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W Auto switch models D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F5F D-F5NTL D-F5W D-J59W D-F5BAL D-F5 D-J5 D-A5/A6 D-A3 D-A44 D-G39 D-K39 D-A59W D-F5NTL D-F5F Bore size (mm) Bore size (mm) A B A B A B B A B Hs Hs Ht Hs Ht A Hs 125 125 0 0 2 2 4.5 4.5 8.5 8.5 9.5 9.5

D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W Auto switch model D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-F59F D-F5W D-J59W D-F5BAL D-F5 D-J5 D-A5/A6 D-A3 D-A44 D-G39 D-K39 MLGP D-A59W D-F5NTL RLQ Bore size (mm) Bore size (mm) MLU A B A B A B A B Hs Hs Ht Hs Hs Ht 125 125 0 0 2 2 4.5 4.5 9.5 9.5 116 126 75.5 69.5 74.5 70 ML1C 140 140 0 0 2 2 4.5 4.5 9.5 9.5 124 134 81 76.5 80 76.5 160 160

D: With auto drain (N.O.) P Q S R Drain cock Gray: N.C.

901 to 1000 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 600 601 to 700 701 to 800 801 to 900 134 CP96 Series Dimensions Basic: CP96S (D) B C (JJ) W Bore size Stroke With rod boot at both ends PL 2 x EE port PL Cushion valve Width across flats SW Width across flats SW WB WA WB WA KK D D e e d d KK 2 x 4 x RT L9 VD BG A L12 BG VD G f A L12 l 2 x h + L8 +

407 578 11-LEFG40-S-450 654 457 628 11-LEFG40-S-500 704 507 678 10 4 600 11-LEFG40-S-550 754 557 728 11-LEFG40-S-600 804 607 778 Model L A B n D E 11-LEFG40-S-650 854 657 828 12 5 750 11-LEFG40-S-700 904 707 878 11-LEFG40-S-750 954 757 928 11-LEFG40-S-800 1004 807 978 14 6 900 11-LEFG40-S-850 1054 857 1028 11-LEFG40-S-900 1104 907 1078 11-LEFG40-S-950 1154 957 1128 16 7 1050 11-LEFG40-S-