SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2KL16-200Z-M9NWM-B"

MGJ For the applicable auto switch model, refer to the table below. b d Table position detector arm MGP a Auto switch mounting bracket MGQ Cylinder Unit/Applicable Auto Switch/Refer to pages 1719 to 1827 for detailed specifications of auto switches.

ID20 ID30 ID40 ID60 Model 80 155 330 780 20 37 85 195 100 192 415 975 Recycled air flow rate Note) (L/min (ANR) Outlet air flow rate (L/min (ANR) Inlet air flow rate (L/min (ANR) Port size (Nominal size B) Weight (kg) 1 4 1 2 1 2 3 4 7 8.5 18.5 25 Supply dry air with a low dew point below 30C. Compact and lightweight without heater and electric control board.

Magnet: Built-in Magnet, Series: J2K, Mounting: Single Foot, Bore Size: 16mm, Stroke: 200mm, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: Single Knuckle Joint, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches

Extension locking F Retraction locking B CLJ2 CLM2 1 CLG1 Drop prevention Emergency stop CL1 A MLGC 2 B A CNG B MNB CNA A A CNS 3 B B CLS CLQ A RLQ A 4 B MLU B MLGP ML1C Mounting Caution 1. Be sure to connect the load to the rod end with the cylinder in an unlocked condition. If this is done in the locked state, it may cause damage to the lock mechanism. 2.

AS600 (258) AS420 (102) AS600 (258) AS600 (258) AS600 (258) AS800 (586) AS500 (123) 1-A 2-B 1-C 2-A 2-B 1-A 2-B 2-A 2-B 2-B 2-B 2-B 2-B 1-A 2-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B 2-A 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 20 8, 10 1/4 500 9.5 0 1,000 2,000 3,000 Maximum speed Vmax (mm/s) 50 12, 16 1/4, 3/8 1000 19 63 Composed effective area So (mm2) Composed effective area So (mm2)

7 o i Piston rod B-side piston Rod cover Piston rod B-side piston Rod cover Component Parts: Standard Piping No. Description No.

B side parallelism to A side 65 65 25 15 15 Mass (g) Refer to Graph (1). MXQ B side traveling parallelism to A side Note) The shock absorber service life is different from that of the MXQ cylinder depending on operating conditions.

): Dimension of the D-A96 D-A9V D-M9V D-M9WV D-M9AV Auto switch Auto switch Hs Hs A B A B 21.5 (23.5) 23.5 14.5 14.5 12.5 12.5 ( ): Dimension of the D-M9AV D-A7/A80 D-A73C/A80C D-A79W D-F7/J79 D-F7W/J79W D-F79F/F7BA Auto switch Auto switch Hs Hs Hs Hs A B A B D-A7H/A80H D-F7V/F7WV D-F7BAV D-J79C Auto switch Auto switch B A A B 10 Auto Switch Mounting Series CJ2Y Auto Switch Proper Mounting

O 2 x N 4.2 b Section b-b Use two through-holes for mounting. 50, 63 Flat washer: 4 positions (Included) 4 x RR 4 x RH Washer b' 4 x O 4 x N b' Section b'-b' Use four through-holes for mounting.

Auto switch mounting surface Bore size (mm) 20, 25 63, 80, 100 32, 40, 50 Port side Port side Port side C A C A C A B B B Auto switch mounting surface Auto switch mounting surface Auto switch mounting surface Auto switch model Port side A, B, C sides A, B, C sides Port, A, B, C sides BQ-2 BQ2-012 Two kinds of auto switch mounting brackets are used as a set.

Retraction stroke end E E1 H H G B F (C) A E E1 H H G B MXQR-BT8 MXQR-JT8 A F Stroke adjustment range (mm) A B C F G H J K 1) E E1 Applicable size Model MXQR 6 M2.5 x 9 M6 x 0.75 1 4 8 6 28.5 8.5 19 18 12 MXQR-BT6 1.4 MXQR-BT8 MXQR 8 M3 x 11 M8 x 1 5 12 40.8 8 10 24.5 24 20 7 MXQR-JT8 1.4 6 MXQR-BT12 MXQR12 M4 x 14 M8 x 1 12 40.8 10 14 29 28 18 7 5 MXQR-JT12 1.4 7 46.7 MXQR-BT16 MXQR16 M5

A B A B A B A B A B A B A B A B 40 50 63 80 100 6 4 3.5 1.5 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 ML2B 3.5 1.5 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 8.5 7.5 6 5 2.5 3 9 4.5 6.5 14 12.5 1.5 2 8 3.5 5.5 13 11.5 12 10 9.5 7.5 6 6.5 4.5 8 10 17.5 16 4 4.5 12.5 6 8 15.5 14 13.5 12.5 11 10 7.5 8 14 9.5 11.5 19 17.5 6.5 7 13 8.5 10.5 18 16.5 D-A9 and D-A9V cannot be mounted on 50.

D-Y7P/Y7PV D-Y7W D-Y7WV D-Y7BAL D-A5 D-A6 D-A3 D-A44 D-G39 D-K39 D-F5W D-J59W D-F5BAL D-F5 D-J5 D-F59F Auto switch model D-A9 D-A9V D-A59W D-F5NTL Bore size (mm) A B B B B A B B A B A A A A 125 140 160 4 4 8 8 1.5 1.5 0 0 2 2 4.5 4.5 9.5 9.5 4 4 8 8 1.5 1.5 0 0 2 2 4.5 4.5 9.5 9.5 4 4 8 8 1.5 1.5 0 0 2 2 4.5 4.5 9.5 9.5 The above shown are the proper auto switch mounting positions for detection

100.5 125.5 150.5 79.5 175.5 200.5 B A MXW8 W 11.5 7.5 7.5 32.5 7.5 7.5 V 120.5 145.5 170.5 99.5 195.5 220.5 A 51 31 31 31 31 B 104 124 149 174 199 MXW12 W 31 11 11 11 11 V 124 144 169 194 219 W V A 34.5 34.5 59.5 34.5 34.5 34.5 B 235.5 260.5 135.5 160.5 185.5 210.5 MXW16 W 14.5 14.5 39.5 14.5 14.5 14.5 V 225.5 280.5 155.5 180.5 205.5 230.5 A 43.5 43.5 43.5 43.5 68.5 43.5 43.5 B 293.5 318.5