LAT Applicable Stroke Table*4 V: Standard Model Stroke [mm] LZ 200 300 400 500 600 700 800 900 1000 1200 1500 LEJS40 V V V V V V V V V V LEJS63 V V V V V V V V V V LC3F2 *4 Please consult with SMC for non-standard strokes as they are produced as special orders. For auto switches, refer to pages 142 to 144.
/D-M9P(V)/D-M9B(V) For details about certified products conforming to international standards, visit us at www.smcworld.com.
Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Perpendicular In-line 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Type Special function Electrical entry Wiring (Output) M9NV M9N V V V v v IC circuit 3-wire (NPN) Solid state auto switch 5 V, 12 V 3-wire (PNP) M9PV M9P V V V v v 2-wire 12 V M9BV M9B V V V v v 3-wire (NPN) 5 V, 12 V M9NWV M9NW
300 400 500 600 0 200 400 600 800 1000 1200 Speed: V [mm/s] Speed: V [mm/s] LEFS32/Ball Screw Drive Horizontal Vertical 30 50 Lead B Lead B 40 Work load: W [kg] Work load: W [kg] 20 30 Lead A Lead A 20 Lead H 10 Lead H 10 0 0 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 Speed: V [mm/s] Speed: V [mm/s] LEFS40/Ball Screw Drive Horizontal Vertical 70 Lead B 30 60 Lead B Work load:
For details, refer to page 443. 413
CHA Series How to Mount and Move the Auto Switch
How to Mount and Move the Auto Switch Auto switch mounting screw M2.5 x 0.45 x 4 L Watchmakers (precision) screwdriver
If this is not done, the tie-rods or piston rod assembly will be damaged. 75
Series C96 How to Mount and Move the Auto Switch 1 Tie-rod Mounting Type Mounting Bracket
BQ-1 BQ-2 BQ2-012 Weight (g) 1.5 1.5 5 259
CHQB/CHQWB Series How to Mount and Move the Auto Switch
A72H A73H 200 V A72 A73 A73C Yes 100 V Relay, PLC 12 V 2-wire Connector 24 V Diagnostic indication (2-color indication) A79W Grommet 3-wire (NPN) 3-wire (PNP) F79 F7P J79 F79W F7PW J79W M9NV M9PV M9BV F9NWV F9PWV F9BWV M9N M9P M9B F9NW F9PW F9BW F7NV F7PV F7BV J79C F7NWV F7BWV 5 V, 12 V IC circuit Grommet 2-wire 12 V Connector Relay, PLC Yes 24 V 3-wire (NPN) 3-wire (PNP)
A72H A73H 200 V A72 A73 A73C Yes 100 V Relay, PLC 12 V 2-wire Connector 24 V Diagnostic indication (2-color indication) A79W Grommet 3-wire (NPN) 3-wire (PNP) F79 F7P J79 F79W F7PW J79W M9NV M9PV M9BV F9NWV F9PWV F9BWV M9N M9P M9B F9NW F9PW F9BW F7NV F7PV F7BV J79C F7NWV F7BWV 5 V, 12 V IC circuit Grommet 2-wire 12 V Connector Relay, PLC Yes 24 V 3-wire (NPN) 3-wire (PNP)
A C F U U M V E A V L Heater (Option) (Maintenance space) Auto switch (Option) B J XLA XL H XLQ XLQ G XM XY DXSA A XVD XGT CYV A (mm) Model A 120 133 178 190 B 38 48 66 79 C 1 1 2 2 D 12 11 11 E 30 40 55 75 F 17 26 41 52 G 40 39 63 68 H 87 91 129 142 J XLAQ-16 XLAQ-25 XLAQ-40 XLAQ-50 40 50 65 70 Note) The heater (Option) is not available with XLAQ-16. 471 Aluminum One-touch Connection and
M9 M9V F9W(V) B Electrical entry is in the direction C (mm) Proper mounting position Proper mounting position Proper mounting position D-M9 D-F9W D-M9V D-F9WV D-M9 D-F9W D-M9V D-F9WV D-M9 D-F9W D-M9V D-F9WV Model Model Model A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C
M9 M9V F9W(V) B Electrical entry is in the direction C (mm) Proper mounting position Proper mounting position Proper mounting position D-M9 D-F9W D-M9V D-F9WV D-M9 D-F9W D-M9V D-F9WV D-M9 D-F9W D-M9V D-F9WV Model Model Model A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C
Type Load voltage Wiring (Output) 3 (L) 1 (M) 0.5 (Nil) Auto switch model Band mounting DC AC Applicable load Lead wire length (m) Indicator light Electrical entry 5 (Z) M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC A93 100 V Yes 12 V 24 V 2-wire Grommet Reed auto switch Note 1) Lead wire length symbols: 0.5 mNil M9BW 1 m M M9BWM 3 m L M9BWL 5 m Z M9BWZ
Lead wire length (m) Auto switch model Electrical entry direction Load voltage Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 3 (L) Applicable load AC DC 12 V In-line A93 Reed auto switch 2-wire Grommet Yes Relay, PLC 100 V 24 V M9N 3-wire (NPN) 12 V Solid state auto switch Grommet Yes Relay, PLC 24 V M9B 2-wire 12 V Lead wire length symbols 0.5 mNil
Example) AR30-03BG-NR-A-X406 Nq Body size 20 25 30 40 Symbol Description Nw Pipe thread type Nil Rc V V V V N NPT V V V V F G V V V V + 01 1/8 V 02 1/4 V V V V 03 3/8 V V V 04 1/2 V 06 3/4 V + Ne Port size a Mounting Nil Without mounting option V V V V B Note 2) With bracket V V V V H With set nut (for panel mount) Note 3) V V V V + Option Note 1) Nr b Pressure gauge Nil Without pressure
Mounting Symbol Description Single rod Double rod B Basic v v L Axial foot v v F Rod flange v v G Head flange v v C Single clevis v D Double clevis v T Center trunnion v v Pivot bracket Number of auto switches Nil No bracket N Pivot bracket Cylinder stroke [mm] Refer to page 26 for standard strokes.
Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Tie-rod mounting Band mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Wiring (Output) Type Special function Electrical entry 3-wire (NPN) 24 V 5 V, 12 V M9N V V V v v IC circuit 3-wire (PNP) M9P V V V v v 2-wire 12 V M9B V V V v v Terminal conduit 3-wire (NPN) Grommet G39 2-wire 12 V
Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Tie-rod mounting Band mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Wiring (Output) Type Special function Electrical entry M9N V V V v v 3-wire (NPN) G59 V V v v 24 V 5 V, 12 V IC circuit 3-wire (PNP) M9P V V V v v G5P V V v v Grommet 2-wire 12 V M9B V V V v v K59 V V v v Terminal
Magnet: Built-in, Mounting: Basic, Bore: 16mm, Stroke: 15mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.