Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -,
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto
Magnet: Built-in, Mounting: Basic Style, Bore Size: 20mm, Stroke: 100mm, Cushion: Air Cushion, Rod Boot: None, Lock Style: Rear End Lock Locking Style, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Basic Style, Bore Size: 20mm, Stroke: 125mm, Cushion: Air Cushion, Rod Boot: None, Lock Style: Rear End Lock Locking Style, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Basic Style, Bore Size: 20mm, Stroke: 25mm, Cushion: Rubber Bumper, Rod Boot: Heat Resistant Tarpaulin, Lock Style: Rear End Lock Locking Style, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Basic Style, Bore Size: 20mm, Stroke: 25mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: Rear End Lock Locking Style, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Mechanically Jointed Rodless Cylinder/Basic Type Series MY3A/3B 16, 20, 25, 32, 40, 50, 63 How to Order B M9BW 16 300 HL Basic MY3 Type Short type (Rubber bumper) Standard type (Air cushion) Number of auto switches A Nil S n 2 pcs. 1 pc. n pcs. B Made to Order For details, refer to page 14.
24 24 24 28 105 105 117 117 40 44 44 44 121 122 124 124 48 48 48 52 15 17 29 29 33 34 36 38 25 27 39 39 45 46 48 50 110 110 120 120 124 124 124 128 60 60 77 77 83 84 86 88 200 200 200 200 200 200 200 200 Note) Refer to the Manufacture of Intermediate Strokes in Best Pneumatics No. 2-2 for intermediate strokes excluding the standard strokes.
~ 2200 Setting of OUT1 output set value 2 R/W HYS mode hysteresis S16 200 Y 0 ~ 2400 Setting of OUT1 hysteresis 3 R/W Wind mode lower limit set value S16 1000 Y -200 ~ 2200 Setting of OUT1 output set value (lower limit of window comparator) 4 R/W Wind mode upper limit set value S16 2000 Y -200 ~ 2200 Setting of OUT1 output set value (upper limit of window comparator) 1240 0X04D8 5 R/W Wind
CCT40-200 SCCS, #1 CCT63-200 SCCS, #2(#2+#13) CCT100-200 SCCS, #3(#3+#14) CCT63 SCCS, #13 CCT100 SCCS, #14 CCT100-200 SCCL, #1(#1+#12) CCT160-200 SCCL, #2(#2+#13) CCT100 SCCL, #12 CCT160 SCCL, #13 4.12-7 Air-hydro Converter Series CCT How to Order CCT 63 100 Effective oil level stroke (mm) Air-hydro converter Converter nominal size/stroke (mm) 63 100 160 50, 100, 200, 300, 400, 500
Maximum Allowable Moment MY1B/M1 MY1B/M2 MY1B/M3 200 300 400 500 40 50 100 30 200 20 50 40 30 100 10 20 40 50 3 4 5 30 10 20 Moment Nm Moment Nm Moment Nm 2 5 4 3 10 1 MY1B40 MY1B40 5 4 3 2 MY1B40 MY1B40 MY1B40 MY1B40 0.3 0.4 0.5 MY1B32 1 2 MY1B32 MY1B32 MY1B25 0.2 1 0.5 0.4 0.3 MY1B25 MY1B25 0.1 0.4 0.5 0.2 0.3 0.05 0.04 0.03 0.2 0.1 0.02 0.06 0.1 100 200 300 400 500 1000 1500 100 200 300