Standard Stroke Standard stroke (mm) Note) Bore size (mm) Symbol Specifications 25, 50, 75, 100, 125, 150 20 -XA Change of rod end shape 25, 50, 75, 100, 125, 150 25 25, 50, 75, 100, 125, 150, 200 32 25, 50, 75, 100, 125, 150, 200, 250 40 Note 1) Intermediate stroke except mentioned above is produced upon receipt of order.
Applicable Auto Switch Model Refer to p.5.3-2 to 5.3-75 for the detailed specifications of auto switches.
Auto Switch Specifications Connector PLC: Abbreviation of Programmable Logic Controller D-C73C (With indicator light) D-C73C Auto switch model Applicable load Relay, PLC Load voltage 24 VDC (4) Load current range 5 to 40 mA Contact protection circuit None Internal voltage drop 2.4 V or less Indicator light Red LED lights when ON.
MHS4-32D MHS4-32D 75 75 Pressure 0.6 MPa Pressure 0.6 MPa 60 60 0.5 MPa 0.5 MPa Gripping force (N) Gripping force (N) 0.4 MPa 0.4 MPa 45 45 0.3 MPa 0.3 MPa 30 30 0.2 MPa 0.2 MPa 15 15 0.1 MPa 0.1 MPa 0 0 10 10 20 20 30 30 40 40 50 50 Gripping point L (mm) Gripping point L (mm) F F Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-
Contact Protection Box: CD-P11, CD-P12 Auto Switch Hysteresis
Wn Y-axis Yn Z-axis Zn X-axis Xn Z X Wa 0 mm 5 mm 0.88 kg 65 mm 111 Wb 0 mm 42.5 mm 4.35 kg 150 mm 210 Y Y Wc 111 mm 42.5 mm 0.795 kg 150 mm Wd 210 mm 42.5 mm 0.5 kg 150 mm n = a, b, c, d 3.
Wn Mass mn X-axis Xn Y-axis Yn Z-axis Zn Z X Wa 0.88kg 65mm 0mm 5mm 111 Wb 4.35kg 150mm 0mm 42.5mm Y 210 Y Wc 0.795kg 150mm 111mm 42.5mm Wd 0.5kg 150mm 210mm 42.5mm n = a, b, c, d 3 Calculation of composite center of gravity m = mn = 0.88 + 4.35 + 0.795 + 0.5 = 6.525kg 1 m X = x (mn x xn) 1 6.525 = (0.88 x 65 + 4.35 x 150 + 0.795 x 150 + 0.5 x 150) = 138.5mm 1 m Y = x (mn x yn) 1 6.525
. *1RSQB12-10m 5 45 CQ-M3X45L RSQB16-10m 7.5 55 CQ-M3X55L -15m 60 X60L RSQB20-10m 7 Example) CQ-M3X55L 2 pcs. 55 CQ-M5X55L -15m 60 X60L -20m 65 X65L RSQB32-10m 9 Mounting bolt 60 CQ-M5X60L -15m 65 X65L -20m 70 X70L RSQB40-20m 9.5 C D 75 CQ-M5X75L -25m 80 CQ-M5X80L -30m 85 X85L RSQB50-20m 9 75 CQ-M6X75L -25m 80 X80L -30m 85 X85L *1 Be sure to use the attached flat washers when mounting 12
80 85 75 80 85 D 40 48 53 55 60 65 60 65 70 Mounting method: Mounting bolt for through-hole mounting style of RSQB is available as an option.
Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com B U A 36.7 D-H7 D-H7W D-H79F D-H7BAL B U A 29 D-H7C B U A 38.2 Proper Auto Switch Mounting Position Auto Switch Mounting Height D-C7 D-C8 D-H7 D-H7W D-H79F D-H7BAL U Auto switch model D-H7BAL D-H7W D-H7 D-H7C D-C7 D-C8 D-C73C D-C80 D-C73C D-C80C D-H7NF D-H7C
MM Relief port FX 20, 25 Eh8 D FZ I 20 to 32 Standard port Relief port Width across flats NA 4-FD 45 1.5 AL 32, 40 A F N K N S + Stroke FT H FY Z + Stroke ZZ + Stroke 40 (mm) 4 7 FD E 20-0.033 0 52 40 40 34 B FX FZ FY G FT 13 8 AL D K MM NA NN B1 B2 Bore size ZZ Z H H2 H1 S P N I F C2 A 66 60 60 60 75 75 75 11 8 8 8 40 32 25 20 24 22 22 18 50 45 45 41 8 8 8 6 6 5 22 17 17 13 41 32 32 26
Extension end 8 10, 20, 30, 40, 50, 75 Rubber stopper Retraction end Both ends 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Standard type Nil PNote 1) Axial piping type Note 1) The combination of axial piping type and both ends adjusters or retraction end adjusteris not
75 30 1 5.5 11 62 12.5 73 14 28 87 RJ0806LN CY1S20-Z M10 x 1 M6 x 1 Rc1/8 NPT1/8 G1/8 40 70 89 90 38 1.5 4.5 9 73 16.5 87 18.5 37 106 RJ1007LN CY1S25-Z M14 x 1.5 M6 x 1 Rc1/8 NPT1/8 G1/8 40 70 98 90 42 1.5 4.5 9 73 16.5 96 18.5 37 106 RJ1412LN CY1S32-Z M20 x 1.5 M8 x 1.25 Rc1/8 NPT1/8 G1/8 40 75 118 110 50 3 5.5 11 91 18.5 116 18.5 37 128 RJ2015HN CY1S40-Z M20 x 1.5 M8 x 1.25 Rc1/4 NPT1/
Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.
, 100,125,150, 25, 50, 75, 100, 125,150,200 Relief type Vacuum suction type 1/8 10-/21-CG1RN32 10-/21-CG1RN40 32 40 25, 50, 75, 100, 125,150,200 250,300 50 63 20 25 32 40 50 63 10-/21-CG1RN50 10-/21-CG1RN63 11-/22-CG1RN20 11-/22-CG1RN25 11-/22-CG1RN32 11-/22-CG1RN40 11-/22-CG1RN50 11-/22-CG1RN63 1/4 Non-lube Double acting Not available 25, 50, 75, 100,125,150, Single rod 25, 50, 75, 100
Information End Lock Cylinder Series CBJ2 / 16 Cylinder stroke (mm) 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes are available in 1 mm increments without stroke adjustment with a spacer. For types with auto switch, refer to Minimum Strokes for Auto Switch Mounting on page 2.
Auto Switch Specifications Connector PLC: Programmable Logic Controller D-C73C (With indicator light) D-C73C Auto switch model Applicable load Relay, PLC Load voltage 24 VDC Load current range (4) 5 to 40 mA Contact protection circuit None Internal voltage drop 2.4 V or less Indicator light Red LED illuminates when turned ON.
CL CL1 Rod Side Flange Style Bore size (mm) MLGC B BZ FT FD FX FZ FY Rod side flange style: CLG1FN Head side flange style: CLG1GN 25 30 30 36 65 75 75 82 38 45 45 52 52 60 60 66 5.5 5.5 6.6 6.6 57.5 6 7 7 8 20 25 32 40 CNG 69 69 76 MNB For long stroke, refer to page 9-2-32.
Low Friction: Double Acting Single Rod Series CJ2Q 10, 16 How to Order Bore size 10 16 10mm 16mm Mounting Basic Axial foot Front flange Double clevis Standard stroke (mm) B L F D 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 CJ2Q L 16 60 Standard L 16 60 C73 CDJ2Q With auto switch Number of switches With auto switch (Built-in magnet) 2 1 n S n Auto switch
Wn Mass mn X-axis xn xa xb xc xd Y-axis yn ya yb yc yd Z-axis zn za zb zc zd X 1 mt = x (mn x xn)w Wa Wb Wc Wd ma mb mc md Y 1 mt = x (mn x yn)e D1 mt = x {mn x (A + zn)} r Z -X (n = a,b,c,d) Refer to the following sections 1 to 4 to calculate the center of gravity and the total load.