Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 159, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 300mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 250mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 50mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 350mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 700mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 125mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
NPT or c port threads available as standard O Die cast aluminum covers for red!
S 1 p c . n n p c s . L Long leads uountng B Front Nose Mount C -Rear Pivot E -Double End K -Non-Rotating Rod R -Block Mount W-Double Rod Auto.Switch 853. D-853 Gsg D-G59 B54. D-854 K59 D-K59 864 .
dr to the current leakage llowing throuth the C-R element.
(Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Mounting Bracket)
Magnet: D (Built-in), Mounting: C (Single Clevis), Bore Size: 40mm, Stroke: 300mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: HN (Rear End Lock Non-locking Style), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: S (1 pc.), Auto Switch Mounting Bracket: C (Mounting Bracket
Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. End lock cylinder, CBG1, Double acting, single rod, 7 mounting styles available, Bore sizes *: 20, 25, 32,
C. KQB2 fittings can be used with fluid, and in environments having a large temperature change. Configuration variations have been improved to 17 models. Applicable tube sizes are +3.2 to +16 and 1/8" to 1/2".
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 40mm, Stroke: 200mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: HN (Rear End Lock Non-locking Style), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Mounting Bracket)