(Red Green Red) PLC: Abbreviation of Programmable Logic Controller D-G5W, D-K59W (With indicator light) CJ1 D-G59W D-G5PW D-K59W Auto switch model Wiring type 3-wire 2-wire CJP Output type NPN PNP Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC CJ2 Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less CM2 Load voltage 28 VDC or less 24 VDC (10
(Red Green Red) PLC: Abbreviation of Programmable Logic Controller D-G5W, D-K59W (With indicator light) D-G59W D-G5PW D-K59W Auto switch model Wiring type 3-wire 2-wire Output type NPN PNP Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load
(Red Green Red) PLC: Abbreviation of Programmable Logic Controller D-G5W, D-K59W (With indicator light) CL D-G59W D-G5PW D-K59W Auto switch model Wiring type 3-wire 2-wire CL1 Output type NPN PNP Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC MLGC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less CNG Load voltage 28 VDC or less 24 VDC (10
(Red Green Red) PLC: Abbreviation of Programmable Logic Controller D-G5W, D-K59W (With indicator light) D-G59W D-G5PW D-K59W Auto switch model Wiring type 3-wire 2-wire Output type NPN PNP Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load
(Red Green Red) PLC: Abbreviation of Programmable Logic Controller D-G5W, D-K59W (With indicator light) D-G59W D-G5PW D-K59W Auto switch model Wiring type 3-wire 2-wire Output type NPN PNP Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load
Information End Lock Cylinder Series CBJ2 / 16 Cylinder stroke (mm) 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes are available in 1 mm increments without stroke adjustment with a spacer. For types with auto switch, refer to Minimum Strokes for Auto Switch Mounting on page 2.
Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-G5W, D-K59W (With indicator light) The proper operating range can be determined by the color of the light.
Load voltage Lead wire length (m) Applicable load Auto switch model Tie-rod mounting Band mounting Indicator light Wiring (Output) Pre-wired connector Special function Type Electrical entry DC AC 0.5 (Nil) 3 (L) 5 (Z) 1 (M) M9N M9P M9B G39C K39C M9NW M9PW M9BW M9NA1 G59 G5P K59 G39 K39 G59W G5PW K59W G5BA1 3-wire (NPN) 5 V, 12 V IC circuit Grommet 3-wire (PNP) 24V 12 V 2-wire
Magnet: D (Built-in), Mounting: B (Basic Style), Style: A (Non-lube Air Cushion), Bore Size: 20mm, Stroke: 150mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type), Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Models Standard strokes (mm) 32 40 50 63 MGP 25, 50, 75, 100, 125, 150, 175 200, 250, 300, 350, 400 M L Intermediate strokes (in 5mm increments) are produced by installing spacers of 5, 10, 15 and 20mm widths. When a special intermediate stroke body is needed, contact SMC.
Weight (g) D-P5DW Auto switch model 0.5 Lead wire length (m) 3 150 5 244 Magnetic Field Resistance Auto Switch Internal Circuit When the AC welding current is 16000 A or less, the operational distance between the welding conductor (welding gun or cable) and the cylinder or auto switch can be 0 mm. Please consult with SMC when exceeding 16000 A.
Lead wire length (m) Load voltage Auto switch model Tie-rod mounting Band mounting Indicator light Wiring (Output) Pre-wire connector Special function Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) AC DC 3-wire (NPN equivalent) Z76 5 V IC circuit Grommet B53 B54 A33 A34 A44 B59W G59 G5P K59 G39 K39 G59W G5PW K59W G5BA G59F Z73 A54 A33C A34C A44C A59W Y59A Y7P J51 Y59B G39C
Lead wire length (m) Load voltage Auto switch model Tie-rod mounting Band mounting Indicator light Wiring (Output) Pre-wire connector Special function Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) AC DC 3-wire (NPN equivalent) Z76 5 V IC circuit Grommet B53 B54 A33 A34 A44 B59W G59 G5P K59 G39 K39 G59W G5PW K59W G5BA G59F Z73 A54 A33C A34C A44C A59W Y59A Y7P J51 Y59B G39C
150 0.3 MPa 0.3 MP 0.3 MPa 0.3 MPa 0.3 MP 0.3 MPa 200 200 0.3 MPa 0.3 MPa 0.3 MPa 0.3 MP 0.3 MPa 100 100 0.2 MPa 0.2 MP 0.2 MPa 0.2 MPa 0.2 MP 0.2 MPa 0.2 MPa 0.2 MPa 0.2 MP 0.2 MPa 0.2 MPa 100 100 50 50 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MP 0.1 MPa 0.1 MPa 0.1 MP 0.1 MPa 50 100 150 200 0 0 50 100 150 200 0 40 80 120 160 200 0 40 80 120 160 200 Gripping point R (mm) Gripping point
How to Order Standard L 40 150 CM2Y L H7BW S 40 150 CDM2Y With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.
Grease pack GR-L-005 (5 g) GR-L-010 (10 g) GR-L-150 (150 g) RB Operating Precautions J Warning 1. It might not be able to control CUX10 by meter-out at a low speed operation. DCaution -X 1.
F5PW Indicator light / Operation D-A59W D-859W D-F5-W, DGs',W, D-J59W, D-Fs'F, D-.J59W, D-K59W. DJsBAL ON operarios f-l-l t u s e l t l l o r r Caution 6 When handling, please avoid dropping, cylinder nicks, and excessive shock.
F5PW Indicator light / Operation D-A59W D-859W D-F5-W, DGs',W, D-J59W, D-Fs'F, D-.J59W, D-K59W. DJsBAL ON operarios f-l-l t u s e l t l l o r r Caution 6 When handling, please avoid dropping, cylinder nicks, and excessive shock.