values) Specifications Bore size (mm) Item Bore size Suction flow rate L/min (ANR) 20/25/32/40 50/63/80/100 20 25 32 40 50 63 80 100 10 20 1.5 MPa 1.0 MPa 0.05 MPa Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing) Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Stroke length tolerance Piston speed 10-/11-: 30 to 400

Lead wire length (m) Applicable load Load voltage Auto switch model Indicator light Pre-wired Type Electrical entry Wiring (output) Special function 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None connector AC DC Tie-rod mount Band mount M9N 3-wire (NPN) G59 IC circuit 5 V, 12 V M9P 3-wire (PNP) Grommet G5P 24 V M9B 12 V 2-wire K59 G39 K39 Reed auto switch Solid state auto switch 3-wire (NPN) 2-wire 5 V

Electrical entry Applicable bore size 0.5 () 3 (L) 5 (Z) None (N) DC AC 20 to 63 20 to 100 3 wire (NPN) C76 IC 5V Yes B53 PLC B54 12V Grommet 200V or less Reed switch Solid state switch No B64 12V 100V Yes C73 2 wire 24V Relay PLC 5V, 12V 100V or less No IC C80 12V Yes C73C Connector 5V, 12V 24V or less No IC C80C Yes Grommet B59W Diagnostic indication (2 color) 3 wire (NPN) G59

Standard Strokes Bore size [mm] Standard stroke [mm] Note 1) Long stroke [mm] Note 2) 40 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500 800 Refer to pages 18 to 23 for cylinders with auto switches. 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500, 600 1200 Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at

, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80: 1400 100: 1500 Refer to pages 19 to 23 for cylinders with auto switches. 80, 100 Intermediate strokes not listed above are produced upon receipt of order.

Bore size (mm) Standard stroke (mm) Note 1) Long stroke (mm) Note 2) Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at stroke end) and mounting height Operating range Auto switch mounting bracket/Part no. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600

, 450, 500 Replacement Parts: Seal Kits 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Kit No.

, 450, 500 Replacement Parts: Seal Kit 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit no. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.

, 450, 500 Replacement Parts: Seal Kit 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit no. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.

C76 5V IC circuit Yes B53 PLC B54 12V Reed switch Solid state switch 200V or less Grommet B64 No 12V C73 Yes 100V 2 wire 24V Relay, PLC 5V, 12V C80 No IC circuit 100V or less 12V C73C Yes Connector 5V, 12V C80C No IC circuit 24V or less Diagnostic indication (2 color indicator) Grommet B59W Yes 3 wire (NPN) H7A1 G59 IC circuit 5V, 12V 3 wire (PNP) H7A2 G5P Grommet H7B K59 2 wire 12V

To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit. 63 50 50 40 40 YES 100 200 300 400 500 100 200 300 400 500 NO Does the mounted load exceed the load given in the diagram? Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K.

100 200 300 400 500 100 200 300 400 500 Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K. NO NO YES Is it possible for cable of stroke reading cylinder to be wired separately from the power line? Is there any influence of noise? YES NO YES NO Can the system be operated below 14.5 mT? Do not use it since it will result in a miscount.

To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit. 63 50 50 40 40 YES 100 200 300 400 500 100 200 300 400 500 NO Does the mounted load exceed the load given in the diagram? Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K.

J 500 General purpose cylinder 50 mm/s 100 3000 mm/s 1000 mm/s 2000 mm/s D500 mm/s 400 Cushion chamber Relief valve Relief valve body -X 4. Finish cushioning Stroke [mm] 300 Transfer equipment 400 N, 1000 mm/s (For 32) Transferring to the opposite stroke, air passes through the cushion seal that functions as a check valve, and starts to push the piston. 2050 200 Data 100 50 mm/s 5.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, END LOCK, ACTUATOR, CBA1/CBA2 TIE-ROD CYL END LOCK, RC, CBA1 80MM OTHERS (COMBO), 20.12820 lb

Cushion adjustment (relief adjustment) man-hours are the same as the adjustment (cushion needle adjustment) for general purpose cylinders. 200 150 High power cylinder Quality of Cushioning (RHCF40-500, Load mass 5 kg, Supply pressure 0.5 MPa, Horizontal operation) Buffer capacity [J] 500 General purpose cylinder (50 mm/s) 100 3000 mm/s 2000 mm/s 1000 mm/s 400 500 mm/s Stroke [mm] 300 50 200

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto

This is a legacy product. Please contact us for the latest version.sales@ocaire.com