1.5 m, 3 m 8.8 (6) (9.3) 18 (17.9) (A, B port: 12) 4 x M5 Mounting hole (Recommended tightening torque: 2.9 Nm) L2 1.5 42.7 Connector Connecting Base (L4) (DIN rail mounting hole pitch: 12.5) (Fitting for the type with P/E ports on the U and/or D sides) (5.3) 18 (L3) (Station 1) (Station n) D-sub, Flat Ribbon One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.: 12, 1/2" Terminal
B IN OUT 8-18 L E H A DIN terminal: D Conduit: C Approx. 280 N (N) J J (44) G 1/2 M M G 1/2 Cable 6 to 12 (Q) Conduit terminal: T J (N) 32 25 G 1/2 M (mm) Grommet Conduit DIN terminal Conduit terminal Electrical entry (AC/Class B coil) Model M 93 N 33 36 36 M 88 N 51.5 54 54 M 89 N 68.5 71 71 Q 56.5 59 59 M 88 N 103.5 Q 72.5 75 75 Normally closed VXD2272 VXD2382 VXD2392 Normally open VXD2270
Stations (Maximum 16 stations) Formula L1 = 25n + 63, L2 = 25n + 76 n: Stations (Maximum 16 stations) L n Dimensions L n Dimensions 8 263 276 L1 L2 7 238 251 8 263 276 L1 L2 6 213 226 7 238 251 5 188 201 6 213 226 4 163 176 5 188 201 3 138 151 4 163 176 1 2 113 126 3 138 151 1 2 113 126 88 101 88 101 L n L n 9 288 301 15 463 476 14 413 426 13 388 401 12 363 376 11 338 351 10 313 326 9 288
2 x 2 x A B A B A B A B 60 80 100 115 235 (221) 264.5 (250.5) 300 (286) 319 (305) 60 77 96 113 46 60 76 85 34 40 50 60 24 36 41 50 135 164.5 200 219 50 60 79 90 77 95.5 111 119 1 8 VNC 1 4 1 4 VNH Note) ( ): CE compliant product (-Q) VND Model J K L M N O P Q R S T U V VNH1 -10A A B VNH2 -15A A B VNH3 -20A A B VNH4 -25A A B M5 x 0.8 depth 5.5 M6 x 1 depth 6 M8 x 1.25 depth 6 M8 x 1.25 depth
Dimensions Formula: L1 = 41n + 76, L2 = 41n + 96 n: Stations (Maximum 12 stations) Formula: L1 = 41n + 76, L2 = 41n + 96 n: Stations (Maximum 12 stations) L n Dimensions 2 158 178 9 445 465 2 158 178 9 445 465 3 199 219 10 486 506 3 199 219 10 486 506 4 240 260 11 527 547 4 240 260 11 527 547 5 281 301 12 568 588 5 281 301 12 568 588 6 322 342 6 322 342 7 363 383 7 363 383 8 404 424 L1 L2
Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: C6H (ø6 One-touch Fitting, Straight Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: ø6 One-touch Fitting, Straight Type, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -
Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 Handling Warning Thoroughly read the Operation Manual.
Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for each 5 m. (At 15 m: Reduced by up to 20%) Note 7) A reference value for correcting an error in reciprocal operation. Note 8) Impact resistance: No malfunction occurred when the actuator was tested with a drop tester in both an axial direction and a perpendicular direction to the lead screw.
2 2-Rc 3 4 2-Rc1 Model J L K M N O P Q R S T U V M5 X 0.8 Depth 5.5 20 24 24 29 36 48 51 25 30 35 38 30 40 50 56 37 43 50.5 58.5 75 100 126 141 88 118 148 163 34 44.5 60.5 66.5 10.5 16 19.5 15.5 62 6 X 8 7 X 0 9 X 2 9 X 2 202.5 232 267 286.5 VNH1 -10A VNH2 -15A VNH3 -20A VNH4 -25A A B A B A B A B M6 X 1 Depth 6 70 92 109 M8 X 1.25 Depth 6 M8 X 1.25 Depth 6 4.2-34 2 Port Valve for Steam
1 2 3 4 5 6 7 Stations D-side 8 U-side M12 Female thread 2-C8 3(R) port 0 DIN rail clamp screw 1 62.5 60 (12) 40.5 25 9.5 7.5 18.5 M12 Male thread 20.5 (7.5) 2n-C3, C4, C6, M5 C3: 3.2 One-touch fitting C4: 4 One-touch fitting C6: 6 One-touch fitting M5: M5 thread 2-C8 1(P) port 34 P = 10.5 Formulas: L1 = 10.5n + 45, L2 = 10.5n + 93.5 n: Stations (maximum 16 stations) n L L1 L2 L3 L4 1 55.5
/Japanese 1pc.) 3 Y strainer (40meshes) 25A 1pc. 4 Barrel nipple 25A 1pc. 5 Anchor brackets The anchor bolts are not attached 2pc.
Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 15. In locations where strong impacts or vibrations occur. 16.
Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: M5 Female Thread, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -
1 pc. (4) Barrel nipple 25A 1 pc.