supply plug for LECA6 Terminal name Function Details M24V terminal/C24V terminal/EMG terminal/BK RLS terminal are common ( ).
Thread type Nil Rc F G N NPT T NPTF 04 1/2 06 3/4 10 1 SA VA JIS Symbol VM N.C. N.O. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Specifications VR Operating type Air operated type Type of actuation N.C./N.O.
(20A) 3 4 10 (25A) 1 7 240 VAC, 50/60 Hz 9 Other 12 (32A) 1 4 1 14 (40A) 1 2 1 VP470 Option Note) There is no 3 position type for Series VP470.
(Normally open) B Port size (IN, OUT port) Port size Rc (Nominal size) VP3145 VP3165 VP3185 Symbol Electrical entry 03 (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 04 G Grommet Conduit terminal DIN terminal TL D 06 10 12 14 20 T (32A) 1 4 1 (40A) 1 2 1 Conduit terminal with indicator light TS Conduit terminal with surge voltage suppressor TZ Conduit terminal with light/surge voltage suppressor DL
Common supply () 0V M24V C24V EMG BK RLS Motor power supply (+) Control power supply (+) Stop (+) Lock release (+) Motor power supply (+) supplied to the driver Control power supply (+) supplied to the driver Input (+) for releasing the stop Input (+) for releasing the lock 0V M24V C24V EMG BK RLS 36 Series LECPA Wiring Example 2 Parallel I/O Connector: CN5 When you connect a PLC, etc.,
Common supply () 0V LEHZ LECP6 LEC-G LECP1 LECPA LEHZJ LEHF LEHS M24V C24V EMG BK RLS Motor power supply (+) Control power supply (+) Stop (+) Lock release (+) Motor power supply (+) supplied to the controller Control power supply (+) supplied to the controller Input (+) for releasing the stop Input (+) for releasing the lock 0V M24V C24V EMG BK RLS Wiring Example 2 Parallel I/O Connector
This is the input (+) that releases the lock. 0V M24V C24V EMG BK RLS CN1 Power Supply Connector Terminal for LECA6 (PHOENIX CONTACT FK-MC0.5/7-ST-2.5) Power supply plug for LECA6 Terminal name Function Function details M24V terminal/C24V terminal/EMG terminal/BK RLS terminal are common ().
Do not supply 24VDC power supply constantly to the [BK RLS (Lock release)] terminal. Stop supplying 24VDC power supply to the [BK RLS (Lock release) terminal during normal operation. If power is supplied to the [BK RLS] terminal continuously, the lock will be released, and workpieces may be dropped at stop (EMG).
. -106090%RH -33- 5.5 5 5.6 OFF SVRE OFF [BK RLS]DC24V [BK RLS] [BK RLS]DC24V [BK RLS] EMG /LEC -34- 6./ 6.1 / 10 1 LEF16 40mm LEF25 60mm LEF32 70mm LEFS40 105mm 6.2.
Do not supply 24 VDC power supply continuously to the [BK RLS (Lock release)] terminal. Stop supplying 24 VDC power supply to the [BK RLS (Lock release) terminal during normal operation. If power is supplied to the [BK RLS] terminal continuously, the lock will be released, and workpieces -13- may be dropped when the stop signal (EMG) is received. 9.
/See 1.2 Specifications on p.5 Stop supplying 24VDC power supply to the [BK RLS] terminal 2) 24VDC is supplied to "BK RLS" terminal of controller/CN1 power /see 2.7 Actuator with lock supply connector.
/See 2.1 Specifications on page 9 2) 24VDC is supplied to "BK RLS" Stop supplying 24VDC power terminal of controller/CN1 power supply to the [BK RLS] terminal supply connector.
/See 2.1 Specifications on page 9 2) 24VDC is supplied to "BK RLS" Stop supplying 24VDC power terminal of controller/CN1 power supply to the [BK RLS] terminal supply connector.
) 1 VQZ 04 06 10 12 14 20 VZ Option (32A) 1 4 1 (40A) 1 2 1 Coil rated voltage VS 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz JIS Symbol Internal pilot
3 Port Air Operated Valve VPA3145/3165/3185 Series How to Order 04 4 5 1 VPA3 Thread type VPA Air operated valve Nil Rc G NPT NPTF F N T Port size (IN, OUT port) Number of pilot 1 Single Symbol Port size Rc size VPA3145 VPA3165 VPA3185 Body size (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 03 04 1 2 1 4 6 06 10 12 14 20 8 1 2 1 Valve option Nil For ordinary pressure For vacuum and low pressure
JSY3000 SY30V-25AS JSY5000 SY50V-25A Nil Standard a-side pilot valve T With power-saving circuit (Made to Order) * Pilot cover x 1 + B tight flat head screw x 1 Rated voltage Pilot cover w 5 24 VDC 1 Socket Caution q w 1. The coil specification and voltage (including light/ surge voltage suppressor) cannot be changed by changing the pilot valve assembly. 2.
3 Port Air Operated Valve VPA3145/3165/3185 Series How to Order 04 4 5 1 VPA3 Thread type VPA Air operated valve Nil Rc G NPT NPTF F N T Port size (IN, OUT port) Number of pilot 1 Single Symbol Port size Rc size VPA3145 VPA3165 VPA3185 Body size 03 04 (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 1 4 6 1 2 06 10 12 14 20 8 1 2 1 Valve option Nil For ordinary pressure For vacuum and low pressure
(Normally open) B Port size Rc (Nominal size) VP3145 VP3165 VP3185 Symbol 03 (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 Electrical entry 04 CE-compliant 06 10 12 14 20 TL D T G Grommet Conduit terminal DIN terminal Conduit terminal with indicator light SYJ (32A) 1 4 1 (40A) 1 2 1 VQZ TS (50A) 2 Symbol Internal pilot
How to Order X214 06 M5 S AS 2 2 1 1FM 2 2 1 01 06 S AS X214 1F Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Body size Body size Option Option Model Applicable tubing O.D. Model Port size Control method Applicable tubing O.D.
9No.PF-OMN0009CN-F * , *PVC PVC PVC () PVC PVC , -10No.PF-OMN0009CN-F PF3W5 48 () 3 A : 04 20 40 11 21 0.5~4 L/min 2~16 L/min 5~40 L/min 10~100 L/min 50~250 L/min 2 04 20 40 11 21 R 04 20 40 11 21 S 250L/min G L/min(gal/min) / : SI : G : 1[L/min]=0.2642[gal/min] 1[gal/min]=3.785[L/min] 1=9/5+32 L/min 100L/min250L/min Rc N NPT F G IS0228 1 N M8(3m) 04 20 40 11 21 03 3/8 04 1/2 06