SX5000-57-6 SX3000-146-2 SX5000-138-1 SV2000-55-1SV2000-55-2A SV2000-21-1 (M3 x 30) VZ1000-11-1SV1000-69A SX7000-57-5 SX3000-146-2 SV3000-65-1 SV3000-55-1SV3000-55-2A SV3000-21-1 (M4 x 35) VZ1000-11-4SV3000-69A SX3000-57-4 SX3000-146-2 SX3000-181-1 SV1000-55-1SV1000-55-2-1 SX3000-22-2 (M2 x 24) VZ1000-11-1SV1000-69A SY9000-11-2 SX3000-146-2 SV4000-65-1 SV4000-55-1SV4000-55-2A SV2000-21-2
(Option) JXC-MA1 Page 606-11 VUSB cable (Option) JXC-MA1-2 Cable length: 3 m Page 606-11 VController setting software (Option) JXC-MA1-1 Page 606-11 PC Provided by customer 559-0 A System Construction/Parallel I/O (JXC73/83) Provided by customer. The connected actuators should be ordered separately. Provided by customer.
11 11 NCA D-A5/A6 D-A59W D-A3/A44 13 13 13 14 14 15 D9 9 10 11 11 11 10 D-Y59/Y69 D-Y7P/Y7V D-Y7W/Y7WV 7 5.5 5.5 7 7.5 6.5 5.5 -X D-Y7BAL 6 3.5 3.5 3.5 4 4.5 5 20D-F5/J5 D-F5W/J59W D-F5BAL/F5NTL D-F59F 3.5 4 4 4.5 4.5 4.5 5 Data D-G39/K39 D-P5DWL 9 4 9 4 9 4 10 4.5 10 4 11 11 4.5 4.5 These values are given as guidelines including the hysteresis and are not guaranteed.
Refer to Table 5.4-11 Offset setting for details. (1) (2) Offset setting Table 5.4-11 Offset setting No. Indication Item Explanation Setting range (1) Offset Temp.
(Refer to page 11 for details.) When compressed air containing ozone (possibly generated from other machinery and equipment present in a plant) enters a pneumatic system, it adversely affects the system's rubber components.
27 25 60 27 30 6 19 8 14 1/4 3/8 3/8 1/2 1/2 Refer to p.3.4-18 for further information on rod end nuts and accessories. 58 13 17 up to 600 20 17 52 12 11 27 47.3 61 M8 X 1.25 M18 X 1.5 159 40 90 17 11 30 25 70 7 19 0 32 35 18 58 17 up to 600 20 17 64 10 11 27 54.8 M18 X 1.5 170 40 15.5 68.5 M10 X 1.25 98 17 14 31 25 7 19 0 85 32 35 18 71 21 up to 750 21 25 78 14 13 32 65.8 M22 X 1.5 204
D-Y7NW(V) Auto Switch Weight Table DC (+) Brown [Red] Unit: g Main switch circuit OUT Black [White] D-Y7BW D-Y7PW Model D-Y7NW 11 11 11 Lead wire length 0.5m 54 54 54 Lead wire length 3m DC () Blue [Black] Auto Switch Dimensions D-Y7PW(V) D-Y7W DC (+) Brown [Red] Main switch circuit OUT Black [White] DC () Blue [Black] D-Y7BW(V) OUT (+) Brown [Red] Main switch circuit D-Y7WV OUT () Blue [
(Refer to page 12.) 11 Multi-Axis Step Motor Controller JXC73/83/92/93 Series Wiring Example 1 For 4 Axes 1 pc.
02 11 stations 2 stations (2) Specified layout (Up to 23 solenoids possible.) 20 20 stations Note 1) Double wiring specifications: Single, double, 3 position and 4 position solenoid valves can be used at all of the manifold stations.
16 15 8 21 4.5 11 66 + Stroke 27.5 93.5 + Stroke 10, 16, 20, 25 Mounting nut Rod end nut G1 G2 NN 2-P I NA D J N2 N1 MM A F S + Stroke F H ZZ + Stroke (mm) Bore size (mm) A D NN F G1 P G2 MM S I ZZ H J N1 N2 NA M5 x 0.8 16 15 4 8 15 6 M12 x 1 M4 x 0.7 65 18.5 101 28 11 20 16 10 M5 x 0.8 22 15 5 10 15 6 M14 x 1 M5 x 0.8 74 22 114 30 12 21 19.5 16 Rc 1/8 28.5 18 8 13 25 8.5 M20 x 1.5 M8 x
11-MXJ8(L)Without adjusterGrade 3 (Class 100 or equivalent)1
11-MXJ8(L)Without adjusterGrade 3 (Class 100 or equivalent)1
11-MXJ8(L)Without adjusterGrade 3 (Class 100 or equivalent)1
11-MXJ8(L)Without adjusterGrade 3 (Class 100 or equivalent)1
11-MXJ8(L)Without adjusterGrade 3 (Class 100 or equivalent)1
11-MXJ8(L)Without adjusterGrade 3 (Class 100 or equivalent)1
11-MXJ8(L)Without adjusterGrade 3 (Class 100 or equivalent)1
11-MXJ8(L)Without adjusterGrade 3 (Class 100 or equivalent)1
11-MXJ8(L)Without adjusterGrade 3 (Class 100 or equivalent)1
11-MXJ8(L)Without adjusterGrade 3 (Class 100 or equivalent)1