Construction/Dimensions (mm) R Note 2) F Note 1) Model PA M MD MM LA L C HB B HA W A REA25 36 5 M4 M5 x 0.8 30 70 8.0 28.5 46 21 47 20 5.5 7 REA32 47 6 M5 M6 x 1.0 35 80 9.5 36 60 27.5 61 22.5 6.0 8 REA40 55 6 M5 M6 x 1.0 40 92 9.5 41 70 28.5 71 26 6.0 8 REA50 65 8 M6 M8 x 1.25 40 110 11 49 86 35 87 35 6.0 11 REA63 80 10 M6 M8 x 1.25 50 122 18 57 100 42 101 36 7.0 11 Note 1) Dimension F provides
11 16 10 72 94 50 36 5 20 45 16 50 CS1 100 110 60 115 12 11 20 10 55 20 89 41 5 25 113 60 C76 Mounting style (E) C85 C95 CP95 NCM NCA D-X 20Bore size (mm) d2 CK S5 K1 K2 l3 G1 l1 G2 EM G3 CA H6 R1 Data 32 6.6 7 8 11 10 38 51 10 21 18 26 31 32 10 40 9 10 11 12 41 54 10 24 22 28 35 36 11 6.6 50 9 11 12 15 12 50 65 12 33 30 32 45 45 12 63 11 12 15 16 52 67 14 37 35 40 50 50 15 9 80 11 12.5
-X 20Stop Data 10-2-11 11 Series REA Dimensions REA25/32/40 Effective thread depth J L 0 0.1 B NN G 4-MM H G 2-port size X D I NB NB T N K W N S + Stroke F NA F R ZZ + Stroke (mm) B D F G H I K L MM x J N NA NB NN Model Port size REA25 REA32 REA40 Rc 1/8 46 27.8 13 8 20.5 34 10 70 M5 x 0.8 x 8 15 30 13 M26 x 1.5 Rc 1/8 60 35 16 9 22 40 15 80 M6 x 1.0 x 8 17 36 15 M26 x 1.5 Rc 1/4 70 43 16
-X 20Stop Data 10-2-11 11 Series REA Dimensions REA25/32/40 Effective thread depth J L 0 0.1 B NN G 4-MM H G 2-port size X D I NB NB T N K W N S + Stroke F NA F R ZZ + Stroke Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (mm) B D F G H I K L MM x J N NA NB NN Model
DC (+) Brown Main switch circuit OUT Black Auto Switch Weights Unit: g DC (s) Blue D-Y7NW(V) D-Y7PW(V) D-Y7BW(V) Model 0.5 11 11 11 Lead wire length m 3 54 54 54 D-Y7PW, Y7PWV 5 88 88 88 DC (+) Brown Main switch circuit Auto Switch Dimensions OUT Black D-Y7W Mounting screw M2.5 x 4l Slotted set screw DC (s) Blue Indicator light 3.4 2.5 SMC SMC 6.2 5 D-Y7BW, Y7BWV 29 OUT (+) Brown Main switch
Note 2) For the specifying way of ordering numbers for the solenoid valve with adapter assembly, refer to page 10-16-4. 10-16-19 20 Series MVGQ Proper Auto Switch Mounting Position (Detection at stroke end) Operating Range Bore size (mm) Auto switch model 16 100 12 20 25 32 40 50 63 80 D-Z7/Z8 8.5 14 7.5 9.5 9.5 11 11 11 13 13 A B D-Y59/Y69/Y7P/Y7PV D-Y7W/Y7WV 6 11.5 5 6 6.5 8.5 8.5 9 10
11 11 40 88 109 21 M10 x 1.25 37 136 30 11 25 to 800 0.13 0.18 40 65 45 12 42 3/8 11 11 11 46 95 118 21 M10 x 1.25 36 136 30 11 25 to 800 0.2 50 76 52 15 46 1/2 14 13 11 58 115 145 27 M10 x 1.25 43 150 30 13 25 to 800 0.15 63 90 63 15 52 1/2 18 15 14 65 132 165 27 M12 x 1.5 43 156 35 15 25 to 800 0.2 80 110 80 17 65 3/4 18 18 16 87 155 190 22 M16 x 1.5 44 166 35 18 25 to 1000 0.3 0.18 100
11 11 D-A59W 13 13 13 14 14 15 D-A3m/A44 9 9 10 11 11 11 D-Y59m/Y69m D-Y7P/Y7mV D-Y7mW/Y7mWV D-Y7BA 5.5 5.5 7 7.5 6.5 5.5 D-F5m/J59 D-F5mW/J59W D-F5BA/F5NT D-F59F 3.5 4 4 4.5 4.5 4.5 D-G39/K39 9 9 9 10 10 11 D-P3DWA 3 4.5 4.5 5 5 5.5 D-P4DW 4 4 4 4.5 4 4.5 DValues which include hysteresis are for guideline purposes only, they are not a guarantee (assuming approximately 30% dispersion) and
11 11 13 13 13 14 14 15 9 9 10 11 11 11 D-Y59/Y69 D-Y7P/Y7V D-Y7W/Y7WV D-Y7BAL 5.5 5.5 7 7.5 6.5 5.5 D-F5/J5 D-F5W/J59W D-F5BAL/F5NTL D-F59F 3.5 4 4 4.5 4.5 4.5 DD-G39/K39 D-P4DWL 9 9 10 11 11 11 -X 4 4 4 4.5 4 4.5 Since this is a guideline including hysteresis, not meant to be guaranteed.
Symbol (mm) 11 Helical insert screw specifications -X168 P HTB Model HTA Aperture dia.
depth 8 14 depth 10.5 17.5 depth 13.5 17.5 depth 13.5 5.5 5.5 5.5 5.5 6.6 9 11 11 11 0 0.052 0 0.062 0 0.062 0 0.062 0 0.074 28 35 35 43 59 10.5 15 16 23 Note 1) Dimensions other than above are the same as the standard double acting single rod type.
11 16 10 72 94 50 36 5 20 45 16 50 CS1 100 110 60 115 12 11 20 10 55 20 89 41 5 25 113 60 C76 Mounting style (E) C85 C95 CP95 NCM NCA D-X 20Bore size (mm) d2 CK S5 K1 K2 l3 G1 l1 G2 EM G3 CA H6 R1 Data 32 7 8 11 10 38 51 10 21 18 26 31 32 10 6.6 40 11 12 41 54 10 24 22 28 35 36 11 6.6 9 10 50 11 12 15 12 50 65 12 33 30 32 45 45 12 9 63 15 16 52 67 14 37 35 40 50 50 15 9 11 12 80 12.5 14
11.5 12 17 9 9 9 9 13 13 11.5 12 17 17.5 18 23 15 7 9.5 10 15 15 7 19 11 18 18.5 23.5 15.5 9.5 12 12.5 17.5 17 11 21 15 22.5 23 28 20 9.5 12 12.5 17.5 21.5 11 25.5 15 30.5 31 36 28 3 5.5 6 11 29.5 4.5 33.5 8.5 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
to 800 Up to 800 Up to 1000 Up to 1000 Up to 1000 Up to 1000 Up to 1000 Stroke range Bore size (mm) MM XA Y ZZ MA MB MC NA NB P S M5 x 0.8 M5 x 0.8 M6 x 1 M6 x 1 M8 x 1.25 M8 x 1.25 M12 x 1.75 6 6 12 12 16 16 20 5 6.5 8.5 9.5 12.5 15 20 106 128 155 178 195 221 248 11 11 16 16 16 16 20 10 10 12 12 15 15 23 19 26 21 34 86 107 120 138 150 171 198 4 4 4 4 5 5 6 20 25 32 40 50 63 80 M5 x 0.8
(same side) 60 D-Y59A(B), Y69A(B) Y7P(V) 1 pc., 2 pcs. (different sides) 20 2 pcs. (same side) 70 D-Y7NW(V), Y7PW(V) Y7BW(V) Solid state switch 1 pc., 2 pcs. (different sides) 25 2 pcs. (same side) 70 D-Y7BAL 1pc., 2 pcs.
11 MB-B08 Rotating Angle Method for longitudinal mounting of clevis pivot bracket When there is no air cushion, the unit is equipped with rubber bumpers.
11 MB-B08 Rotating Angle Method for longitudinal mounting of clevis pivot bracket When there is no air cushion, the unit is equipped with rubber bumpers.
) 5 (Max. 11) 5 (Max. 16.5) 8 (Max. 20) 9 (Max. 25) 13 (Max. 33) 13 (Max. 38) With low load shock absorber + Adjusting bolts MY1W Bore size Stroke L TT h h E F EA h EB W F Stroke adjusting unit S (Shock absorber stroke) T MY1W16, 20 F MY1W50, 63 Shock absorber EC EY h 3.6 3.6 3.5 4.5 4.5 5.5 5.5 TT 5.4 (Max. 11) 5 (Max. 11) 5 (Max. 16.5) 8 (Max. 20) 9 (Max. 25) 13 (Max. 33) 13 (Max. 38) S
Applicable actuator and operation range (angle) Sensor unit D-Y7K Air gripper (mm or ) Model Bore size (mm) 10 4 12 16 20 25 32 40 50 63 80 100 MHZ2 MHL2 MHS2 (2 finger) MHS3 (3 finger) MHS4 (4 finger) MHC2 MHW2 Parallel gripper 7 8 8.5 7 5 Wide opening 6.8 10.5 11 12.5 8.5 8 Parallel gripper 6.5 7 7.5 8.5 Parallel gripper 6.5 7 7.5 8 Parallel gripper 6.5 7 7.5 8.5 30 to 10 30 to
11 Since this is a guideline including hysteresis, not meant to be guaranteed.